LCD Display: Shows Time, Day, Temperature, Program Number, and other feature information as required.
YOUR THERMOSTAT REPLACES
Description | KJR-25B |
Heat Pump (No Aux. or Emergency Heat) | Yes |
Heat Pump (with Aux. or Emergency Heat) | Yes |
Standard Heat & Cooling Systems | Yes |
Two Stage Heat & Two Stage Cool | Yes |
Standard Heat Only Systems | Yes |
Millivolt Heat Only Systems– Floor or Wall Furnaces | Yes |
Standard Central Air Conditioning | Yes |
Gas or Oil Heat | Yes |
Electric Furnace | Yes |
Hydronic (Hot Water) Zone Heat-2 Wires | Yes |
Hydronic (Hot Water) Zone Heat–3 Wires | No |
This Thermostat will NOT control 110/220Volt systems.
Read the entire installation section of this Owner's Manual thoroughly before you begin to install or operate your Thermostat.
This thermostat can be used for conventional or heat pump system, Please configure the thermostat according to Configuration Menu before operation.
REMOVE THE MYLAR LABEL FORM THE LCD DISPLAY WINDOW.
All installation is normally performed at your thermostat.
The thermostat provides a 4 minutes delay after shutting of the heating or cooling system before it can be restarted. This feature will prevent damage to your compressor caused by rapid cycling. Note that this delay also applies to the heating system control. It does not provide a delay when there are power outages.you can select the function on or off at the configuration.
This thermostat can be programmed between 45˚F and 95˚F (7˚C and 35˚C). However, it will display room temperatures from 30˚F to 99˚F (0˚C and 37˚C). "HI" will be displayed if the temperature is higher than 99˚F (37˚C), and "LO" will be displayed if the temperature is lower than 30˚F (0˚C).This thermostat will automatically cutoff in Heat mode if the temperature rises above 95˚F (35˚C), and automatically cutoff in Cool mode if the temperature drops below 45˚F (7˚C).
NOTE: if the thermostat measure a temperature over 99˚F(37℃), "HI" will be displayed on the LCD. if the temperature is below 32˚F(0℃). and "LO" will be displayed on the LCD.
Whenever the main power is interrupted or fails, the battery power retains and current time. This thermostat has permanent memory, although you will have to reset your clock when there are power outages.
The thermostat shall be powered by 24 VAC and with batteries as backup.
Fresh alkaline batteries should provide about one year of service. However, when the batteries become drained, "BATT" will alternate on the display with the current time. When this message occurs, install 2 new AA batteries, You have approximately 1 minute to change the batteries and keep thermostat's clock. Once the batteries have become too low to ensure proper operation, your system will be turned off, and the display will be cleared except for "BATT" flashing on the LCD display.
Once only the "BATT" only display occurs, the thermostat is shut down, and your system will no longer operate. In this condition, there is no temperature control of your dwelling. NOTE: The backlight will not function when the thermostat is in low battery condition.
NOTE: If you plan to be away from the premises over 30 days, we recommend that you replace the old batteries with new alkaline batteries prior to leaving.
What You Need
This thermostat includes two #8 slotted screws and two wall anchors for mounting. To install your thermostat, you should have the following tools and materials.
To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.
Before removing wires from old thermostat's switching subbase, label each wire with the terminal designation it was removed from.
Do not use on circuits exceeding specified voltage. Higher voltage will damage control and could cause shock or fire hazard. Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring will damage thermostat and could cause personal injury and/or property damage.
Electric/Gas Switch (Fan Option)
This thermostat is configured from the factory to operate a heat/ cool, fossil fuel (gas, oil, etc.), forced air system. It is configured correctly for any system that DOES NOT require the thermostat to energize the fan on a call for heat. If you system is an electric heat or heat-pump system that requires the thermostat to turn on the fan on a call for heat, locate the ELEC/GAS switch on the back of the thermostat (see fig. 1) and switch it to the ELEC position. This will allow the thermostat to energize the fan immediately on a call for heat. If you are unsure if the heating/ cooling system requires the thermostat to control the fan, contact a qualified heating and air conditioning service person. When the thermostat is configured for Heat Pump, the thermostat will always power the circulator fan on a call for heat in the HEAT mode. The ELEC/GAS switch must be set to match the type of Auxiliary heat your system uses for proper operation in the EMERgency mode.
All wiring diagrams are for typical systems only. Refer to equipment manufacturers' instructions for specific system wiring information.
Heat Pump Terminal Outputs
Refer to equipment manufacturers' instructions for specific system wiring information. You can configure the thermostat for use with the following heat pump system types: HEAT PUMP TYPE 1 1. Single stage compressor system; gas or electric backup. This thermostat is designed to operate a single-transformer system. If you have a two-transformer system, cut and tape off one transformer. If transformer safety circuits are in only one of the systems, remove the transformer of the system with NO safety circuits. If required, replace remaining transformer with a 75VA Class II transformer. After disconnecting one transformer, the two commons must be jumpered together.
THERMOSTAT TERMINALS (HEAT PUMP) | ||
SYSTEM | Heat Pump 1 | Heat Pump 2 |
L | Malfunction | |
C* | 24 Volt(Common) | |
R | 24 Volt Emergency (hot) | |
E/W1 | Emergency Mode 1st stage | |
W2 | HP 1 and Emergency 2nd stage | |
Y1 | Heat and Cool mode 1st stage (compressor) | |
Y2 | No output | 2nd stage compressor |
G | Blower/Fan Energized on call for Heat and Cool Set GAS/ELEC switch for Emergency mode | |
O | Energized in Cool Mode | |
B | Energized in Heat Emergency mode |
Use the terminal output information below to help you wire the thermostat properly for your heat pump system. After wiring, see CONFIGURATION section for proper thermostat configuration
Note:
To prevent static discharge problems, touch side of thermostat to release static build-up before touching any keys.
If at any time during testing your system does not operate properly, contact a qualified serviceperson.
If your system does not have a G terminal connection, skip to Heating System.
EMER bypasses the Heat Pump to use the heat source wired to terminal E on the thermostat. EMER is typically used when compressor operation is not desired, or you prefer back-up heat only.
The step to enter the configuration menu:
INSTALLER/CONFIGURATION MENU | ||||
Step | Press Button | Displayed | Press up or down key to select | Comments |
(Factory Default) | ||||
1 | Backlight Button | MS 2 | SS1 | Single stage, |
MS 2 | Multi-stage | |||
HP1 | Heat Pump (Single stage) | |||
HP2 | Heat Pump (2-stage) | |||
2 | Backlight Button | (RECO)off | on | Recovery enable |
off | Recovery disabled | |||
3 | Backlight Button | (SPAN)2 | 1 | Span(one stage)1 |
2 | Span(one stage)2 | |||
3 | Span(one stage)3 | |||
4 | Backlight Button | (BLIT)on | on | BackLight on |
off | BackLight off | |||
5 | Backlight Button | (SP2)2 | 1 | Span(Two Stage)1 |
2 | Span(Two Stage)2 | |||
3 | Span(Two Stage)3 | |||
6 | Backlight Button | (TEMP)F | F | Selects temperature display °F |
C | Selects temperature display °C | |||
7 | Backlight Button | HOUR(12) | 12 | Selects time format display 12hours |
24 | Selects time format display 24hours | |||
8 | Backlight Button | COMP(OFF) | OFF | Selects Compressor Lockout OFF |
ON | Selects Compressor Lockout ON | |||
9 | Backlight Button | COOL(2) | 2 | This model must select 2 |
1 | Just use for one stage system | |||
10 | Backlight Button | FACT(0) | 0 | Display normal |
1 | Use for another model to go back to factory default | |||
2 | All the setting will go back to factory default |
The configuration menu allows you to set certain thermostat operating characteristics to your system or personal requirements.
The configuration menu table summarizes the configuration options. An explanation of each option follows. Press "Backlight button" to change to the next menu item. To exit the menu and return to the normal operation, press
key. If no keys are pressed within fifteen Seconds, the thermostat will revert to normal operation.
STEP 1:
STEP 2:
STEP 3:
STEP 4:
Reviewing the Current Temperature Setting
Current time and temperature.
The System Selector Switch on the front of the thermostat determines the Operating mode of the thermostat. You may select COOL, OFF, HEAT, In order to take full advantage of this thermostat's feature.
NOTE: Anytime you install or remove the thermostat form the wallplate, slide the System Selector to the OFF position to prevent the possibility of a rapid system On-Off.
The Fan switch should normally be located in the AUTO position. The Fan will be turned on along with normal operation of your system. In a normal gas or oil furnace, the Fan will be turned on by your furnace after its warm-up delay. For electric heat, air conditioning, and heat pump operation, the Fan will turn on with the system. To run the Fan on continuously, slide the Fan switch to the ON position.
NOTE: Clearing the Energy Monitor counter will also clear the Filter Monitor counter, as Filter usage and Total Energy usage are the same. Also, clearing the filter Monitor counter will clear ALL Energy Monitor counters as well.
Your thermostat also keeps a record of the number of hours your filter has been in use. To maximize your system's performance and energy efficiency, change or clear your filter regularly.
NOTE: Clearing the Filter Monitor counter will also clear ALL Energy Monitor counters, as Filter usage and Total Energy usage are the same. Also, clearing the Energy Monitor counters will clear the Filter Monitor counter as well.
The keyboard can be locked to prevent unauthorized changes to the thermostat.
To lock or unlock the keyboard, press and hold run Key for 3 seconds. The keyboard is locked. when LOCK appears on the display.
Your thermostat has an electroluminescent lamp that backlights the display for easy viewing in the dark.
When any key is pressed the display is illuminated. The display will remain illuminated for 8 seconds after the last key is pressed. This allows the light to stay on if you need to operate several keys.
NOTE: If the thermostat is in Low Battery warning condition, the backlight will not operate. Replace with 2 new AA alkaline batteries to restore the Backlight function.
Your thermostat has a two-stage lower battery warning system. When the batteries are first detected to be weak, the first stage low battery warning is indicated by "BATT" flashing on the LCD display. At your earliest convenience, you need to replace the batteries with 2 new AA alkaline batteries.
When the batteries become too weak for normal operation, the thermostat enters the second stage low battery warning which shuts down the thermostat. In this condition, "BATT" flashes alone on the display, and the thermostat will turn your system Off. Your system will remain shut-off until the batteries are replaced.
NOTE: The thermostat will still keep the current Set Temperature and Filter run time in memory until new batteries are installed. After confirming that new batteries have been inserted, the thermostat will return to normal operation.
If the thermostat is unable to control your system due to an unexpected battery problem, the thermostat will enter Error Mode. In this condition, the thermostat flashes "E1","E2","E3"or"E4"on the LCD display, and shuts off your system. To correct this problem, replace the batteries with 2 new AA alkaline batteries, even if you have recently replaced them. Move the battery out, and then hold any key to release the rest energy. Then place the battery again. You will need confirm normal operation.
If Error Mode returns, please call us for further information.
Lcd display | information |
E1 | Sensor Error |
E2 | System switch Error |
E3 | No use |
E4 | E2 memory Error |
If the SYSTEM MONITOR SWITCH is close show the system have wrong. the thermostat flashs "E5"on the LCD display.
Your thermostat will automatically cutoff in Heat mode if the room temperature rises above 95˚F (35˚C). It will cutoff in Cool mode if the room temperature drops below 40˚F (4˚C). Note that if your system has malfunctioned and no longer responds to thermostat controls, the Auto Cut-Off will have no effect.
Problem | Solution |
SCRAMBLED OR DOUBLE DISPLAY (numbers over numbers) |
|
NO DISPLAY |
|
ENTIRE DISPLAY DIMS |
|
AUTO/FAN DOES NOT TURN ON |
|
ERRATIC DISPLAY |
|
IF UNIT CONTINUES TO OPERATE IN THE OFF POSITION |
|
THERMOSTAT PERMANENTLY READS "E1","E2","E3", "E4". |
|
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.