Nikro Industries PW10088 Instruction Manual

Nikro Industries PW10088 Instruction Manual

10 gallon hepa filtered vacuum

Advertisement

Quick Links

10 GALLON
HEPA FILTERED VACUUM
MODEL #PD10088 & PW10088
INSTRUCTION MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Nikro Industries PW10088

  • Page 1 10 GALLON HEPA FILTERED VACUUM MODEL #PD10088 & PW10088 INSTRUCTION MANUAL...
  • Page 2 All Nikro Industries Inc. products that have rated efficiencies of 99.97% @ 0.3 microns and/or 99.99% @ 0.3 microns, have H.E.P.A. filters that have been individually tested to meet these minimum efficiencies. Although all the filters have been pre-tested, the possibility of leaks or filter failure due to handling, transportation, punctures, loaded filters, moisture, wear and tear, etc., does exist.
  • Page 3: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precautions should always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING (THIS APPLIANCE) WARNING – To reduce the risk of fire, electric shock, or injury: 1. Do not leave appliance when plugged in. Unplug from outlet when not in use and before servicing. 2.
  • Page 4: Electrical Specification

    INSPECTION Thoroughly inspect your machine for any shipping damage. Your machine has already been thoroughly tested at the Nikro Industries manufacturing plant prior to shipping. ELECTRICAL SPECIFICATION This machine is designed to operate on a 15 amp. 115V., 60 hz., AC circuit. A deviance of this could cause serious damage to the unit.
  • Page 5 PACKAGING Please do not discard any of the packaging until you have inspected the vacuum and it is operational. Make sure the contents are intact and complete. If there are any missing parts please contact Nikro immediately. CONTENTS 1 - #PD10088 – 10 Gallon HEPA Filtered Vacuum 1 - #PKD100 Tool Kit: #520332 –...
  • Page 6 TANK AND FILTER PREPARATION 1. Place the paper collection bag (#520033) into the bottom of the tank. Pull the cardboard / rubber collar over the down tube, pulling it just above the rib on the down tube. Then gently pull apart the accordion- like pleats so that the bag is open.
  • Page 7 PROCEDURES FOR REMOVING CONTAMINATED FILTERS Caution: When removing contaminated filters or using this machine, you should always wear gloves, clothing and a respirator approved for the particular contaminant that you are working with. FILTER REMOVAL PROCEDURES 1. Turn off and unplug machine 2.
  • Page 8: Lid Assembly

    LID ASSEMBLY PC NO PART NO PART NAME 861313 MOTOR 520302 520009 FILTER MOUNTING PLATE 861969 HEPA FILTER 520215 SMALL SPACER 520002 MOTOR HOLD DOWN 520214 LARGE SPACER 520001 DOME 861761 8-32 X 1 SCREW 862092 10-32 X 5/8 HEX HEAD FLANGE BOLT 861537 8-32 NYLON LOCKNUT...
  • Page 9: Tank Assembly

    TANK ASSEMBLY PC NO PART NO PART NAME 861127 TANK 861128 SMALL CASTER 520220 INTAKE 860803 LATCH NOT SHOWN 520217 INTAKE KNOB NOT SHOWN 520216 INTAKE GASKET NOT SHOWN 540001 UPPER DOWN TUBE ELBOW NOT SHOWN 860468 DOWN TUBE COUPLER NOT SHOWN 861546 LOWER DOWN TUBE...
  • Page 10 OPTIONAL WET PICK-UP CONVERSION 1. Remove all paper filters from the vacuum tank assembly and remove the lower portion of the down tube. (See Photo 1) 2. Place the water shut-off float assembly onto the tank. Make sure the rubber gasket on the float plate is seated on the top rim of the tank (See Photo 2) 3.
  • Page 11: Warranty

    WARRANTY Nikro HEPA Vacuums are warranted for 2 years from the date delivered to the original end user and may not be assigned or transferred. Parts, which become defective due to faulty workmanship or materials during normal use in this period will be repaired or exchanged at no charge if returned and approved by an authorized Nikro service center.