Do not use the equipment if any operating anomalies are found. Avoid temporary repairs. All repairs should be carried out using only qualified spare parts, which must be installed in accordance with their intended use and by a licensed contractor or authorized Aptos service representative.
C) Hang the microinverter on the screw (shown as picture below), and tighten the screw.The silver cover side of the Microinverter should be facing the panel. *Note: Please install the microinverter at least 50cm above the ground/roof for better communication with Aptos DTU.
Refer to the DTU User Manual or DTU Quick Install Guide, and Quick Installation Guide for Aptos Online Registration to install the DTU and set up the monitoring system. Product information is subject to change without notice. (Please download reference manuals at www.aptossolar.com)
Page 16
2.Check the communication between DTU and Aptos monitoring system, the communication between DTU and microinverter. Then try again. 3. If the fault still exists, contact your dealer or Aptos technical support. 1. If the alarm occurs accidentally and the microinverter can still work Software error code normally, no special treatment is required.
Page 17
2. If the alarms occur frequently on all the microinverters in your station, contact the local power operator to check whether there is a grid island. 3.If the alarm still exists, contact your dealer or Aptos technical support. 1.Please make sure that the PV module open-circuit voltage is less Input port1 than or equal to the maximum input voltage.
Flashing Red and Green alternately: Firmware is corrupted. *Note: All the faults are reported to the DTU, refer to the local APP of the DTU or Aptos Monitoring Platform for more information. 6.3 On-site Inspection (For qualified installer only) To troubleshoot an inoperable microinverter, follow the steps in the order shown.
5. Check the DC connections between the microinverter and the PV module. 6. Verify the PV module DC voltage is within the allowable range shown in appendix Technical Data of this manual. 7. If the problem persists, please call Aptos customer support. Warning ...
7.2 Storage and Transportation Aptos packages and protects individual components using suitable means to make the transport and subsequent handling easier. Transportation of the equipment, especially by road, must be carried out by suitable ways for protecting the components (in particular, the electronic components) from violent, shocks, humidity, vibration, etc.
DC current. But the maximum short circuit current must be equal to or less than the maximum input DC short circuit current. The output DC power of PV module is NOT recommended to exceed 1.35 times the output AC power of the microinverter. Refer to “Aptos Warranty Terms & Conditions” for more information. 8.1 DC Input Model...
800 Microinverter is a grid support interactive inverter, which is also known as a Grid Support Utility Interactive Inverter. And these microinverters also comply with California Rule 21. The Grid Support Support functions are controlled on Aptos Monitoring Platform and the DTU is required in this PV system.