The FS-100RM-5 is designed to be powered by a 100 to 240 VAC mains source and/or an optional +12 to +36 VDC power source. If the instrument is acquired without the optional battery back up module, the back panel will contain a black plastic cover instead of a DC connector.
2.0 Safety and Preparation for Use The FS-100RM-5 was designed for indoor use only and is not intended for operation outdoors or in a wet environment. The instrument may be mounted in a standard 19-inch instrumentation rack or may be used on a laboratory bench.
DC mains supply. Make sure you have access to the rear panel or provide an external accessible DC disconnect means for your FS-100RM-5. Please note that the power return (pin 4) is NOT connected to the instrument case ground internally, however both ground connections (pin 4 and pin 6) are available at the DC power connector and may be connected together at this point.
3.0 Front Panel AC Power The AC Power LED turns on when AC power is applied to unit. DC Power The DC Power LED is on when DC power is applied to unit. INPUT A 5 MHz RF signal with a level greater than +10 dBm may be connected to the SMA connector labeled INPUT.
If the instrument was acquired with the optional DC battery back up module, the unit may operate on +12 to +36 VDC at 1 Ampere. When the FS-100RM-5 is set up to operate with both AC and DC power sources at the same time the DC power is used as backup power in case of AC power outages.
5.0 Installation Connecting power The FS-100RM-5 ships with a standard North American or European IEC power cord. The instrument may be mounted in a standard 19-inch instrument rack or may be operated on a laboratory bench. Locate the AC POWER entry module on the rear of the enclosure, connect the power cord and turn on the power.
6.0 Operation Once power is supplied to the instrument and the instrument is turned on, the LED on the front panel labeled AC will turn on. If you also apply the DC voltage the LED labeled DC POWER on the front panel should light up. The 5 MHz input signal to be multiplied should be connected to the SMA connector on the front panel labeled INPUT.
Technical Support Tel: +1 (303) 665-1852 , Fax: +1 (303) 604-6088 support@spectradynamics.com, www.spectradynamics.com AC Power LED does not turn on. Disconnect the power cord. Check the main AC power fuse and power cord. If the fuse is blown replace with same type and rating.
SDI’s option, any product not meeting the said specifications. This warranty shall be in effect for one (1) year from the date a FS-100RM-5 is sold by SDI. SDI makes no other warranty, express or implied, and makes no warranty of the fitness for any particular purpose.