Traxon Technologies ecue e:bus User Introduction Manual

Advertisement

Quick Links

Read the e:bus Introduction Manual and the Safety Instructions
carefully. Subject to modification without prior notice.
Typographical and other errors do not justify any claim for
damages. Modification of the product is prohibited.
This manual is designed for electricians, system administrators,
and product users.
All product names and trademarks mentioned in this manual are
trademarks of their respective owners.
Except for internal use, relinquishment of the instructions to a
third party, duplication in any type or form - also extracts - as
well as exploitation and / or communication of the contents is not
permitted.
Downloads and more information at:
www.ecue.com
Edition:
28.07.23 [EN_ebus_manual_v3p0]
Published by:
Traxon Technologies Europe GmbH
Karl-Schurz-Strasse 38
33100 Paderborn, Germany
©2023 Traxon Technologies Europe GmbH
All rights reserved
Traxon Technologies Europe GmbH
Sales Operations
Karl-Schurz-Str. 38
33100 Paderborn, Germany
+49 5251 54648-0
support@ecue.com
e:bus

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ecue e:bus and is the answer not in the manual?

Questions and answers

Summary of Contents for Traxon Technologies ecue e:bus

  • Page 1 33100 Paderborn, Germany All product names and trademarks mentioned in this manual are trademarks of their respective owners. ©2023 Traxon Technologies Europe GmbH Except for internal use, relinquishment of the instructions to a All rights reserved third party, duplication in any type or form - also extracts - as well as exploitation and / or communication of the contents is not permitted.
  • Page 2 Invalid configurations Cable types and lengths 3.1 Cable types General run lengths Special cabling conditions Glass Touch e:bus, DALI and DMX 5.1 DALI 5.2 DMX 5.3 Comparison WWW.TRAXON-ECUE.COM ©2023 traxon technologies. All rights reserved. e:bus Introduction Manual 07/23 Sheet: 02 / 07...
  • Page 3 A bus topology allows the largest cable length. The maximum stub length is 30 cm. Interfaces are powered via e:bus. Interfaces will be automatically registered and addressed. Defective units will not affect the communication between other devices. A maximum of eight e:bus devices, e.g. e:cue Glass Touches, is supported by one SYMPL e:bus Node. WWW.TRAXON-ECUE.COM ©2023 traxon technologies. All rights reserved. e:bus Introduction Manual 07/23 Sheet: 03 / 07...
  • Page 4 As long as the two e:bus connectors of a user terminal are connected to the master unit’s connectors, regardless if a cable goes from + to + or from + to -, everything will work fine. The two e:bus connectors of a user terminal can be connected to the master unit‘s connectors either way. The terminal devices will recognize the polarity on their own and configure themselves the proper way. WWW.TRAXON-ECUE.COM ©2023 traxon technologies. All rights reserved. e:bus Introduction Manual 07/23 Sheet: 04 / 07...
  • Page 5 Cable types and lengths Cable types The maximum cable length is greatly dependent on device count, topology and cable types as well. Approved cable types for e:bus are AWG 16 (1.5 sqmm) cables and AWG 24 (0.28 sqmm) Cat5 or J-Y(St)Y cables. The following table shows valuable key facts: WWW.TRAXON-ECUE.COM ©2023 traxon technologies. All rights reserved. e:bus Introduction Manual 07/23 Sheet: 05 / 07...
  • Page 6 Comparison Feature e:bus DALI Includes protocol    Self-organizing network  Free topology wiring   Link power  Polarity-insensitive  High-Speed signaling   WWW.TRAXON-ECUE.COM ©2023 traxon technologies. All rights reserved. e:bus Introduction Manual 07/23 Sheet: 06 / 07...
  • Page 7 Introduction Manual — e:bus Introduction Manual | Special cabling conditions  content Please check for the latest updates and changes on the Traxon website. © 2023 TRAXON TECHNOLOGIES. ALL RIGHTS RESERVED. www.traxon-ecue.com...

This manual is also suitable for:

Ecue sympl e:bus node

Table of Contents