Generating an RF Sweep

To generate an RF sweep with the following settings:
• frequency range from 1 GHz to 2 GHz,
• nine sweep points with a 50 ms dwell time at each point
Refer to the following procedures to configure and generate
an RF sweep:
Press
1
Press
2
To set the RF sweep output level at 0 dBm.
Press
3
To open the sweep submenus.
Press Step Sweep softkey
4
To open a submenu for step sweep configurations.
Press RF Start > 1 > GHz
5
To set the start frequency of the sweep to 1 GHz.
Press RF Stop > 2 > GHz
6
To set the stop frequency of the sweep to 2 GHz.
Press # Points > 9 > Enter
7
To set the number of sweep points to nine.
Press More > Step Dwell > 50 > ms
8
To set the dwell time at each point to 50 ms.
Press
9
The annunciator will change from
Press Return > Sweep Mode > RF
10
at a power level of 0 dBm
hardkey
Preset
> 0 > dBm
Amplitude
hardkey
Sweep
hardkey to enable the RF output.