IMPORTANT SAFETY INSTRUCTIONS

Sanitize Thoroughly with Hot Steam

IMPORTANT SAFEGUARDS

warning BEFORE USING THIS APPLIANCE READ ALL INSTRUCTIONS AND CAUTIONARY MARKINGS IN YOUR USER MANUAL AND ON THE APPLIANCE.


DO NOT touch or hold the mains plug with wet hands.


DO NOT approach or touch the steam nozzle when the cleaner is on.


DO NOT operate the cleaner without filling water.

INTENDED USE

  • This appliance is not intended for use by people (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by person responsible for their safety.
  • Close supervision is necessary when any appliance is used by or near children. Children should be supervised to ensure that they do not play with the appliance. Cleaning and user maintenance shall not be done by children unless they are older than 8 and supervised.
  • Use the appliance only for intended household purposes as described in this User Manual. Any other use is not recommended that may cause fire, electric shock, or injury to people.
  • This appliance only for indoor use, do not use it on stairs.

ELECTRICITY SAFETY

  • This appliance must be provided with correct voltage via a professionally installed power socket. Make sure the voltage indicated on the label of the appliance is the same as your local supply.
  • Please use grounded electrical socket.
  • Include instructions pertaining to a risk of fire, electric shock, or injury to persons, for cleaning and user-maintenance, such as lubrication.
  • Please turn the appliance off immediately if any abnormal sounds, smell burning or smoking.
  • DO NOT run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings.
  • DO NOT route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over. Do not step on the cleaner to avoid damage.
  • Do not fill the water tank with hot water or corrosive agents which could cause damage. Use purified water only to avoid any obstruction.
  • Do not use the appliance to clean leather goods, synthetic materials, velvet or other steam sensitive goods directly.
  • To avoid scalding or burning, please keep the steam away from people, animal and plant while using.
  • To avoid accidents, please do not touch the appliance while the hands are wet, please use the appliance with shoes on.

FOR HOUSEHOLD USE ONLY

READ AND SAVE THESE INSTRUCTIONS


Regular Check
Have your mop cleaner checked regularly for any sign of malfunction!

Check if

  • Plug, cord or appliance is damaged.
  • Excessive noise, unpleasant odor or abnormal heat.

Stop using, check FAQ and contact Aspiron Support Team.

Specifications

Model AS-CA001
Input 120V/127V~60Hz
Rated Power 1100W
Water Tank Capacity 410ml

ASSEMBLING YOUR CLEANER

Sanitize Thoroughly with Hot Steam

Parts

Parts

Assemble Your Cleaner

  1. Insert the handle rod into the opening of main body and secure them with the cap bolt.
    Assemble Your Cleaner - Step 1
  2. Wet the mop pad and wring it out. Press the mop pads against the bottom to stick them together.
    Assemble Your Cleaner - Step 2

USING YOUR CLEANER

Sanitize Thoroughly with Hot Steam

Filling Water

  1. Open water tank cap.
  2. Fully fill in with water using the included measuring cup. It's recommended to use purified water to avoid any scales blocking the steam nozzle.
  3. Close the tank cap.

Cleaning

Cleaning

  1. Plug the cleaner in, hold the handle firmly.
  2. Press the Power button to turn on and Steam button to adjust desired steam levels.
  3. Slowly move the cleaner back and forth over dirty area on floor until it is cleaned.
  4. Press Power button to turn off, unplug the cleaner at last.


The cleaner will preheat for about 45s before releasing steam after its first turning on, please do not approach the steam nozzle during preheating to avoid scald.

Cleaning Tips

  • After continuous working for 30 minutes, the cleaner will pause for 40 minutes automatically for overheating protection. During protection, the cleaner cannot be turned on and operated.
  • Using time varies with ground friction, and it will be shortened on rough floors.
  • To avoid damage, especially to some delicate wooden floors, make sure the floor on which the high-temp steam can be used.
  • DO NOT stay or wipe in a same place too long while steaming.

CLEANING AND MAINTENANCE

Sanitize Thoroughly with Hot Steam

warning Always unplug the cleaner before performing any cleaning or maintenance.

  • Use only soft dry cloth to wipe the cleaner. DO NOT immerse the cleaner into water or clean with detergent.
  • Drain the remaining water in the tank after each using, start the cleaner again until no steam comes out.
  • Place in a dry and shady place if not in use for a long time.

TROUBLESHOOTING

Cleaner does not work and indicators do not illuminate.
  • Make sure the cleaner is plugged in.
  • Main power supply fault, ask qualified electricians for help.
No steam comes out, indicators illuminate.
  • No water in the water tank or water runs out, add water to the water tank.
  • The clean is preheating, please wait.
Intermittent steam.
  • Voltage instability, ask qualified electricians for help.

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Aspiron AS-CA001 - Steam Mop Cleaner Manual

Advertisement

Need help?

Need help?

Do you have a question about the AS-CA001 and is the answer not in the manual?

Questions and answers

Table of Contents