Bartington Mag900 Operation Manual

Three-axis magnetic field sensors

Advertisement

Quick Links

INNOVATION IN MAGNETICS
OM4550/1
Operation Manual for
Mag900 & Mag901
Three-Axis Magnetic Field Sensors
www.bartington.com

Advertisement

Table of Contents
loading

Summary of Contents for Bartington Mag900

  • Page 1 INNOVATION IN MAGNETICS OM4550/1 Operation Manual for Mag900 & Mag901 Three-Axis Magnetic Field Sensors www.bartington.com...
  • Page 2: Table Of Contents

    BARTINGTON INSTRUMENTS Table of Contents 1. About this Manual 1.1. Symbols Glossary 2. Safe Use 3. Introduction 4. Overview 4.1. Vector Measurements and Conventions 5. Installation 5.1. Unpacking 5.2. Orientation 5.3. Mounting 5.4. Cable Recommendations 5.5. Pre-Installation Tests 6. Operating Instructions 7.
  • Page 3: About This Manual

    1. About this Manual This manual provides the information necessary to help customers connect, install and operate the Mag900 & Mag901 three-axis magnetic field sensor. Technical specifications of the products, including power supply requirements and analogue output details, can be found in DS4550, whilst outline drawings of both sensor head, electronics...
  • Page 4: Introduction

    BARTINGTON INSTRUMENTS 3. Introduction Figure 1. Mag900 & Mag901. The Mag900 & Mag901 is an unpackaged, three-axis, low power sensor intended for customer system integration. Technical specifications for the Mag900 & Mag901 are provided in datasheet DS4550. Page 4 of 10...
  • Page 5: Overview

    Internal regulation of the power supply ensures the Mag900 & Mag901 is suitable for battery powered operation, over both long and short cables (subject to the minimum supply voltage specified in datasheet DS4550).
  • Page 6: Installation

    5.3. Mounting The Mag900 & Mag901 sensor assembly should be mounted in a stress-free manner using the six mounting holes on the PCB. Dimensions and locations of the holes are shown in outline drawing DR4576.
  • Page 7: Pre-Installation Tests

    BARTINGTON INSTRUMENTS 5.5. Pre-Installation Tests Prior to the installation into the customer’s system, the Mag900 & Mag901 must be fully tested to ensure correct function as follows: Caution: Take care to avoid bending or otherwise damaging the contacts whilst conducting the tests.
  • Page 8: Operating Instructions

    If this occurs, the offset will exhibit drift as it returns to its original offset specification. Caution: Subjecting the Mag900 & Mag901 to fields in excess of 2 x the nominal range may cause inaccuracy in future measurements. Degaussing the sensor can reverse such an effect.
  • Page 9: Storage & Transport

    Caution: Do not expose this instrument to strong magnetic fields while being stored. Caution: Take particular care when cleaning around electrical connections. Bent or damaged pins may cause the Mag900 & Mag901 to malfunction. 10. Environmental Precautions Refer to datasheet DS4550 for maximum environmental, electrical and mechanical ratings.
  • Page 10 ®The copyright of this document is the property of Bartington Instruments Ltd. Bartington is a registered trademark of Bartington Instruments Limited in the following countries: Australia, Brazil, Canada, China, European Union, India, Israel, Japan, Mexico, New Zealand, Norway, Russia, Singapore, South Korea, Switzerland, Turkey, United Kingdom, United States of America and Vietnam.

This manual is also suitable for:

Mag901