FP-01C front panel with a built-in card capture reader for ST-01 speed gate (hereinafter – FP-01C panel) is desig ned for installation on ST-01 speed gate and has a built-in card capture reader for reading and withdrawing proximity cards, issued to the visit ors and meant for retur n at exit (hereinafter –...
FP-01C Front Panel The storage of FP-01C panel in the original package is allowed indoors at ambient temperature from -40°C to +50°C and at relative air humidity up to 80% at +15°C. In the storage room should also be no acid fumes and gases, causing the corrosion.
Assembly and Operation Manual 4 PRODUCT DESCRIPTION Main features In the front panel of the card capture reader there is a container with a lock for card collection. Card reader (to be purchased separ ately) can be built in the panel, it should be installed on the double-sided tape in side in the upper part of the card capture reader panel.
FP-01C Front Panel Parameters of control signals: “Capture card” INPUT is controlled by the output of the ACS-controller, type “dry contact" or “open collector”. The input is “normally opened”, i.e. activation of the input will be done by a control signal the ACS-controller couples to the GND (contact 4).
FP-01C panel installed increases by 68 mm (see Fig. 1). FP-01C panel should be installed on the ST-01 speed gate instead of the standard front panel (see Fig. 1 and ST-01 Operation manual, Section 8.9.2). Before mounting (removing) the panel it is...
ACS-controller – cable for the built-in reader and co ntrol cable f or the card capture reader (10). 3. Install the FP-01C panel on the ST-01 speed gate by using the fixing hooks (5). 4. Install back the speed gate glass cover.
Page 9
Assembly and Operation Manual Figure 5. Diagram for connecting the card capture reader to the ACS-controller via Wiegang interface (list of components mentioned in the Table 1)
FP-01C Front Panel Table 1. List of components of card capture reader connection layouts Legend Item Front panel FP-01C Card capture reader control board Front end indication module Reader installed in a card capture reader (direction B) Reader (direction A) ACS-controller Power supply 24 VDC/2.5A...
Page 11
Assembly and Operation Manual 4. Click "Edit" button on the page toolbar. The "Device properties" window will appear. 5. In the appeared window select "Additional outputs" tab. 6. In the window working area, select "Additional output №..." (number of the output must match the o utput of the controller t hat is physically conne cted to “Capture card”...
Page 12
FP-01C Front Panel of the controller that is physically connected to the “Fault” output of the card capt ure reader) and set the following parameters by using the drop-down menu: set "Standard" value for "Type" parameter, set "Disconnected" value for the "Normal condition of the contact" parameter: ...
Page 13
Assembly and Operation Manual 14. Switch to "Reader № ... " tab (number of the reader must match the reader, which is controlled by the card capture reader). 15. The “Card captured” signal sent by the card capture reader is considered as a confirmation of withdrawal of the card .
Page 14
FP-01C Front Panel 16. In the left part of the working area tab select “Additional outputs activated upon VISITORS valid identifiers” parameter and set: set "For the operation time" value for the "Activation criteria" parameter by using the drop-down list.
Assembly and Operation Manual 5.4.2 CT/L14, CT13 configuration in Web-interface for working with the card capture reader 1. In "Configuration" "Edit" "Operating devices" section, select the OD that is physically connected to the card capture read er, then in OD parameters select "Access by directions" and directions number that is controlled by the card capture reader.
Page 16
FP-01C Front Panel 3. Add the following Internal response in "Configuration" "Edit" "Internal reactions" section: "Source type:" – "Visitor ID card presentation", "Source number:" – "1" (number of OD th at is physically connect ed to the card capture reader), ...
Assembly and Operation Manual 5.4.3 CT/L04.2, CT03.2 configuration in Web-interface for working with the card capture reader Attention! By using Web-interface it’s po ssible to set only the simplest visit or’s card withdrawal algorithm, to amplify the setting ra nge, use PERCo-Web software. The CT/L04 (CT03) controllers are not compatible with configuration via Web-interface.
Page 18
FP-01C Front Panel 3. Add the following Intern al response in "Configuration" "Edit" "Internal response" section: "Source type:" – "Visitor ID card presentation", "Source number:" – "1" (number of OD th at is physically connect ed to the card capture reader), ...
Page 19
Assembly and Operation Manual Example of a ove rview of th e sections "Internal response" and "Physical contacts" after configuration (template – “Turnstile” card capture reader controls the direction number “1”, “Input 6” and “Output 3” are used to cont rol the card ca pture reader, “Input 5” i s used rec eive the “Alarm” signal: 5.
FP-01C Front Panel 6 PERCO WARRANTY PERCo (the Manufacturer) warrants that the FP-01C Front Panel (the Product) complies with applicable statutory safety requirements, electromagnetic compati bility provided that t instructions on storage, installation and operation, given in the Assembly & Operation Manual, are observed.
Page 21
SOPHISTICATED PRODUCTS THAT, IF NOT FAULTY, CANNOT BE RETURNED BACK IF BY SOME REASON THE CUSTOMER DEEMS THEM UNSATISFACTORY The PERCo FP-01C Front Panel is in conformity with the essential requirements of the EU’s Machinery, Low-Voltage and EMC Directives and carries the CE marking accordingly.
Page 22
WARRANTY CARD FP-01C Front panel with a built-in card capture reader for ST-01 Serial number Date of manufacture: ____________________ 20__ Quality Control Seal: _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Date of sale: «...