Peco FP-01C Operation Manual

Front panel with a builtin card capture reader for st01 speed gate section

Advertisement

Quick Links

Front Panel
FP-01C
with a Built in Card Capture Reader
for ST 01 Speed Gate Section
CERTIFICATE AND OPERATION
MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FP-01C and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Peco FP-01C

  • Page 1 Front Panel FP-01C with a Built in Card Capture Reader for ST 01 Speed Gate Section CERTIFICATE AND OPERATION MANUAL...
  • Page 2 FP-01C Front Panel with a Built-In Card Capture Reader for ST-01 Speed Gate Section Certificate & Operation Manual...
  • Page 3: Table Of Contents

    FP-01C front panel with a built-in card capture reader for ST-01 speed gate (hereinafter – FP-01C panel) is desig ned for installation on ST-01 speed gate and has a built-in card capture reader for reading and withdrawing proximity cards, issued to the visit ors and meant for retur n at exit (hereinafter –...
  • Page 4: Technical Specifications

    FP-01C Front Panel The storage of FP-01C panel in the original package is allowed indoors at ambient temperature from -40°C to +50°C and at relative air humidity up to 80% at +15°C. In the storage room should also be no acid fumes and gases, causing the corrosion.
  • Page 5: Product Description

    Assembly and Operation Manual 4 PRODUCT DESCRIPTION Main features  In the front panel of the card capture reader there is a container with a lock for card collection.  Card reader (to be purchased separ ately) can be built in the panel, it should be installed on the double-sided tape in side in the upper part of the card capture reader panel.
  • Page 6: Removal And Installation Of The Card Container

    FP-01C Front Panel Parameters of control signals: “Capture card” INPUT is controlled by the output of the ACS-controller, type “dry contact" or “open collector”. The input is “normally opened”, i.e. activation of the input will be done by a control signal the ACS-controller couples to the GND (contact 4).
  • Page 7: Installation

    FP-01C panel installed increases by 68 mm (see Fig. 1). FP-01C panel should be installed on the ST-01 speed gate instead of the standard front panel (see Fig. 1 and ST-01 Operation manual, Section 8.9.2). Before mounting (removing) the panel it is...
  • Page 8: Connection Layouts Of A Built-In Card Capture Reader

    ACS-controller – cable for the built-in reader and co ntrol cable f or the card capture reader (10). 3. Install the FP-01C panel on the ST-01 speed gate by using the fixing hooks (5). 4. Install back the speed gate glass cover.
  • Page 9 Assembly and Operation Manual Figure 5. Diagram for connecting the card capture reader to the ACS-controller via Wiegang interface (list of components mentioned in the Table 1)
  • Page 10: Troubleshooting

    FP-01C Front Panel Table 1. List of components of card capture reader connection layouts Legend Item Front panel FP-01C Card capture reader control board Front end indication module Reader installed in a card capture reader (direction B) Reader (direction A) ACS-controller Power supply 24 VDC/2.5A...
  • Page 11 Assembly and Operation Manual 4. Click "Edit" button on the page toolbar. The "Device properties" window will appear. 5. In the appeared window select "Additional outputs" tab. 6. In the window working area, select "Additional output №..." (number of the output must match the o utput of the controller t hat is physically conne cted to “Capture card”...
  • Page 12 FP-01C Front Panel of the controller that is physically connected to the “Fault” output of the card capt ure reader) and set the following parameters by using the drop-down menu:  set "Standard" value for "Type" parameter,  set "Disconnected" value for the "Normal condition of the contact" parameter: ...
  • Page 13 Assembly and Operation Manual 14. Switch to "Reader № ... " tab (number of the reader must match the reader, which is controlled by the card capture reader). 15. The “Card captured” signal sent by the card capture reader is considered as a confirmation of withdrawal of the card .
  • Page 14 FP-01C Front Panel 16. In the left part of the working area tab select “Additional outputs activated upon VISITORS valid identifiers” parameter and set:  set "For the operation time" value for the "Activation criteria" parameter by using the drop-down list.
  • Page 15: Ct/L14, Ct13 Configuration In Web-Interface For Working With The Card Capture Reader

    Assembly and Operation Manual 5.4.2 CT/L14, CT13 configuration in Web-interface for working with the card capture reader 1. In "Configuration"  "Edit"  "Operating devices" section, select the OD that is physically connected to the card capture read er, then in OD parameters select "Access by directions" and directions number that is controlled by the card capture reader.
  • Page 16 FP-01C Front Panel 3. Add the following Internal response in "Configuration"  "Edit"  "Internal reactions" section:  "Source type:" – "Visitor ID card presentation",  "Source number:" – "1" (number of OD th at is physically connect ed to the card capture reader), ...
  • Page 17: Ct/L04.2, Ct03.2 Configuration In Web-Interface For Working With The Card Capture Reader

    Assembly and Operation Manual 5.4.3 CT/L04.2, CT03.2 configuration in Web-interface for working with the card capture reader Attention! By using Web-interface it’s po ssible to set only the simplest visit or’s card withdrawal algorithm, to amplify the setting ra nge, use PERCo-Web software. The CT/L04 (CT03) controllers are not compatible with configuration via Web-interface.
  • Page 18 FP-01C Front Panel 3. Add the following Intern al response in "Configuration"  "Edit"  "Internal response" section:  "Source type:" – "Visitor ID card presentation",  "Source number:" – "1" (number of OD th at is physically connect ed to the card capture reader), ...
  • Page 19 Assembly and Operation Manual Example of a ove rview of th e sections "Internal response" and "Physical contacts" after configuration (template – “Turnstile” card capture reader controls the direction number “1”, “Input 6” and “Output 3” are used to cont rol the card ca pture reader, “Input 5” i s used rec eive the “Alarm” signal: 5.
  • Page 20: Perco Warranty

    FP-01C Front Panel 6 PERCO WARRANTY PERCo (the Manufacturer) warrants that the FP-01C Front Panel (the Product) complies with applicable statutory safety requirements, electromagnetic compati bility provided that t instructions on storage, installation and operation, given in the Assembly & Operation Manual, are observed.
  • Page 21 SOPHISTICATED PRODUCTS THAT, IF NOT FAULTY, CANNOT BE RETURNED BACK IF BY SOME REASON THE CUSTOMER DEEMS THEM UNSATISFACTORY The PERCo FP-01C Front Panel is in conformity with the essential requirements of the EU’s Machinery, Low-Voltage and EMC Directives and carries the CE marking accordingly.
  • Page 22 WARRANTY CARD FP-01C Front panel with a built-in card capture reader for ST-01 Serial number Date of manufacture: ____________________ 20__ Quality Control Seal: _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Date of sale: «...
  • Page 25 PERCo Polytechnicheskaya str., 4, block 2 194021, Saint Petersburg Russia Tel: +7 812 247 04 64 E-mail: export@perco.com support@perco.com www.perco.com...
  • Page 26 www.perco.com...

Table of Contents