  • Page 1 AK53 / AK54 User manual MILPUNTS S.L. Camí del mig, 62-64 Carrer D, 15-B 08349 – Cabrera de Mar Barcelona, España Tel.: +34 93 759 38 85 Fax.: +34 93 759 37 24 www.senso.es info@senso.es Ver.1.0...
  • Page 2 USER MANUAL 1 Description The AK53/AK54 model is a temperature controller system for hot runner plastic injection moulding 1.1 Functionality Can read thermocouple or Pt100 Pulse control output Secondary setpoint/Main setpoint Selectable PID control or PI+D control Autotune function 1 voltage free alarm contact.
  • Page 3 3.1 Main Menu When pressed FUNC on normal mode, controller will enter to Menu Mode. The options shown in menu are: Symbol Name Meaning Locked Parameters FrEE: Protected parameters are unlocked Lock: Protected parameters are locked Additional details: Shown if "Lock Configuration" > 5000 Setpoint Temperature value to use as setpoint.
  • Page 4 Range: 0,1 to 100,0 Additional details: Cannot be changed if parameters are locked or autotune is on Integral Time PID control parameter Range: 1 to 4000 Additional details: Cannot be changed if parameters are locked or autotune is on Derivative Time PID control parameter Range: 1 to 4000 Additional details: Cannot be changed if parameters are locked...
  • Page 5 When hold FUNC button for 10 seconds while on Menu Mode, Advanced menu will be shown. If paramemters are locked, a password will be required Symbol Name Meaning Input type tc-J: thermocouple J (0..600ºC) tc-L: thermocouple L (0..600ºC) tc-K: thermocouple K (0..1200ºC) tc-N: thermocouple N (0..1200ºC) tc-t: thermocouple T (0..400ºC) tc-r: thermocouple R (0.1600ºC)
  • Page 6 Alarm Relative Setpoint If "Alarm Setup" is rHi or rLo this value is added to the current setpoint to activate/deactivate alarm status. If "Alarm Setup" is Wnd this value is the maximum deviation of the temperature from the setpoint (higher or lower) before alarm is activated Range: 0 to 9999 Additional details: Shown if "Alarm Setup"...
  • Page 7 Maximum Autotune Maximum allowed value for Proportional Band calculated by Proportional Band Autotune Range from ("Minimum Autotune Proportional Band" +0.1) to 100,0 Minimum Autotune Integral Minimum allowed value for Integral Time calculated by Time Autotune Range: 1-4000 Remember Start Mode Off: Controller always starts in automatic mode On: Controller starts in the last state it was left (Automatic/Manual).
  • Page 8 5 Default Parameters If there is any problem, or password is forgotten everything can be restored to factory settings pressing up and down button on power up. The factory settings are: Setpoint Alarm Setup Diasbled Secondary Setpoint Latched Alarm Alarm Absolute Setpoint Masked Alarm Alarm Relative Setpoint Alarm Direction...