EVSE 2 Charging Station
7335 Production Drive Mentor, OH 44060 Phone: 440-205-9188 Fax: 440-205-9187 sales@nssltd.com www.nssltd.com

Advertisement

Table of Contents
loading

Summary of Contents for North Shore Safety EVSE 2

  • Page 1 EVSE 2 Charging Station 7335 Production Drive Mentor, OH 44060 Phone: 440-205-9188 Fax: 440-205-9187 sales@nssltd.com www.nssltd.com...
  • Page 2: Table Of Contents

    Installation and Operating Instructions | North Shore Safety EVSE2 Series Charging Station | 2 Table of contents 1 Introduction .................................. pg. 3 2 Important Safety Warnings and Cautions ........................pg. 4 3 Regulatory Information ..............................pg. 4 3.1 Regulatory Information ............................4 3.2 Product Specification .............................
  • Page 3: Introduction

    Installation and Operating Instructions | North Shore Safety EVSE2 Series Charging Station | 3 ► Disconnect main service power to the EVSE2 before Introduction Introduction cleaning the unit. Do not use cleaning solvents to clean any part of the EVSE2. Clean enclosure, cable, and...
  • Page 4: Regulatory Information

    Installation and Operating Instructions | North Shore Safety EVSE2 Series Charging Station | 4 Features and Specifications Regulatory Information Regulatory Information The EVSE2 includes ground-fault protection, automatic Regulatory Information Regulatory Information reset upon grid power loss, ground assurance monitoring, and At the end of service life, the EVSE2 should be recycled self-testing capabilities.
  • Page 5 Installation and Operating Instructions | North Shore Safety EVSE2 Series Charging Station | 5 Product Features Product Features Technical Specifications Technical Specifications Ground Fault Voltage and * 240VAC single-phase (US): L1, L2, and 18 mA (nominal; 20mA Max) (US) safety ground.
  • Page 6: Applicable Electrical Systems

    Installation and Operating Instructions | North Shore Safety EVSE2 Series Charging Station | 6 Applicable Electrical 5.1.2 208V 3-Phase Wye Connection Systems Any two of the legs can be used to provide 208V to the EVSE2 with a Wye-connected secondary. For example, L1 and L2, or L1 and L3, or L2 and L3.
  • Page 7: Electrical Requirements

    Installation and Operating Instructions | North Shore Safety EVSE2 Series Charging Station | 7 5.2 Electrical Requirements CAUTIONS CAUTIONS The AC electrical connection must have a grounded, dedicated servicemain. No other loads shall be connected to the same circuit. Use of a non-dedicated circuit could exceed the current rating of the circuit breaker and cause it to trip or open.
  • Page 8: Amperage And Breaker Parameters

    Installation and Operating Instructions | North Shore Safety EVSE2 Series Charging Station | 8 Amperage and Breaker Mounting Instructions Parameters Package Contents ► (1)EVSE2 Series Charging Station The EVSE2 has been factory set at an output current setting of ► (1)EVSE2 Series Charging Station hardware kit: 4 for Table 1 and 5 for Tables 2 and 3.
  • Page 9: Finished Wall Installation

    Installation and Operating Instructions | North Shore Safety EVSE2 Series Charging Station | 9 Finished Wall Installation WARNING: Read all instructions before installing the EVSE2 WARNING: Read all instructions before installing the EVSE2 Ideally, the EVSE2 should be mounted to the studs of a drywall/wood-stud structure, or to a masonry-wall.
  • Page 10 Installation and Operating Instructions | North Shore Safety EVSE2 Series Charging Station | 10 3. Using a 1/8” (3-mm) drill bit, drill 2-holes at the target-points on the template. These two points are vertically located with reference to each other (they are also 4.9 in [125-mm] apart).
  • Page 11 Installation and Operating Instructions | North Shore Safety EVSE2 Series Charging Station | 11 5. Align the EVSE2 to the mounting screws and gently slide the unit down to secure it within the rear mounting slots. Plug the EVSE2 into the appropriate, existing power receptacle.
  • Page 12: Masonry Wall Installation

    Installation and Operating Instructions | North Shore Safety EVSE2 Series Charging Station | 12 Masonry Wall Installation Masonry Wall Installation 1. Using adhesive tape, secure the mounting template (included on page 18 of this manual) to the desired mounting location on the wall surface. Mount the template at a height of 45” from the floor to the bottom of the template.
  • Page 13 Installation and Operating Instructions | North Shore Safety EVSE2 Series Charging Station | 13 3. Remove the template from the wall and install two (2) 3/16” (5-mm) tapered-head masonry screws. Drive these screws leaving a 1/2” space from the top of the screw head to the wall surface.
  • Page 14: Mounting Template

    Installation and Operating Instructions | North Shore Safety EVSE2 Series Charging Station | 14 7.5 Mounting Template 7.5 Mounting Template page 14...
  • Page 15: Power And Status Led Indications

    Installation and Operating Instructions | North Shore Safety EVSE2 Series Charging Station | 15 Power and Status LED Indications Power and Status LED Indications Operating Instructions - Power and Status LED Indications Operating Instructions - Power and Status LED Indications Apply AC power.
  • Page 16: Troubleshooting

    Installation and Operating Instructions | North Shore Safety EVSE2 Series Charging Station | 16 Power and Status LED Power and Status LED 9 Troubleshooting 9 Troubleshooting Indications (cont’d) Indications (cont’d) Connection to vehicle Short red flash unsatisfactory. Normal Charging Sequence...
  • Page 17: Miscellaneous

    Installation and Operating Instructions | North Shore Safety EVSE2 Series Charging Station | 17 Miscellaneous Miscellaneous exclusive remedy, under this warranty, is the repair or replace- ment of the defective device. In no case shall North Shore Safety’s liability exceed the purchase price. This warranty is void 10.1 Maintenance...