IMPORTANT INFORMATION, KEEP FOR OPERATOR
888-994-7636, fax 888-864-7636
unifiedbrands.net
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE.
UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED
IN THIS MANUAL.
FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
WARNING R290 flammable refrigerant in use. Improper installation,
adjustment, alteration, service or maintenance can cause property damage,
injury or death. Read the installation, operating and maintenance instructions
thoroughly before installing or servicing this equipment.
NOTIFY CARRIER OF DAMAGE AT ONCE It is the responsibility of the
consignee to inspect the container upon receipt of same and to determine
the possibility of any damage, including concealed damage. Randell suggests
that if you are suspicious of damage to make a notation on the delivery
receipt. It will be the responsibility of the consignee to file a claim with the
carrier. We recommend that you do so at once.
Manufacture Service/Questions 888-994-7636.
EQUIPMENT DESCRIPTION
MODEL
LENGTH
DEPTH
65348-290
48"
33"
INSTALLATION
CAUTION: THIS UNIT CONTAINS R290 FLAMMABLE REFRIGERANT. USE CAUTION WHEN
HANDLING MOVING AND USE OF THE REFRIGERATOR OR FREEZER. AVOID
DAMAGING THE REFRIGERANT TUBING OR INCREASE THE RISK OF A LEAK.
WARNING: FAILURE
TO
FOLLOW
RECOMMENDATIONS MAY VOID THE WARRANTY ON YOUR UNIT.
WARNING: IT IS IMPORTANT THAT YOUR UNIT HAS ITS OWN DEDICATED LINE.
CONDENSING UNITS ARE DESIGNED TO OPERATE WITH A VOLTAGE
FLUCTUATION OF PLUS OR MINUS 10% OF THE VOLTAGE INDICATED ON
THE UNIT DATA TAG. BURN OUT OF A CONDENSING UNIT DUE TO EXCEEDING
VOLTAGE LIMITS WILL VOID THE WARRANTY.
THE DANFOSS CONTROLLER HAS LOW VOLTAGE PROTECTION AND WILL NOT
OUTPUT VOLTAGE TO THE COMPRESSOR IF VOLTAGE IS LESS THAN 104V.
WARNING: THIS UNIT IS INTENDED FOR USE IN LABORATORIES IN COMMERCIAL,
INDUSTRIAL, OR INSTITUTIONAL OCCUPANCIES AS DEFINED IN THE
SAFETY STANDARD FOR REFRIGERATION SYSTEMS, ASHRAE 15.
Information contained in this document is known to be current and accurate at the time of printing/creation. Reference our product line website for the most updated
product information and specifications. © 2023 Electrolux Professional, Inc. All Rights Reserved.
READ,
NO. OF
STORAGE
HEIGHT
DOORS
(CUBIC FEET)
36"
2
12.89
INSTALLATION
GUIDELINES
AND
This manual provides information for:
65348-290 SELF-CONTAINED
WORK-TOP FREEZER
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE: Due to a continuous program of product improvement, Randell reserves the
right to make changes in design and specifications without prior notice.
NOTICE: Please read the entire manual carefully before installation. If certain
recommended procedures are not followed, warranty claims will be denied.
MODEL NUMBER _________________________
SERIAL NUMBER _________________________
INSTALLATION DATE ______________________
The serial number is located in the cabinet left side
under the drawer track. An example is shown here.
POWER USAGE
COMPRESSOR
(KW PER DAY)
4.02
1/2
SELECTING A LOCATION FOR YOUR NEW UNIT
The following conditions should be considered when selecting a location for your
unit:
1. Floor & Countertop Load: The area on which the unit will rest must be level,
free of vibration, and suitably strong enough to support the combined weights
of the unit plus the maximum product load weight. NOTE: If there is a question
pertaining to weight load limits, consult the factory at 1-888-994-7636.
2. Clearance: Clearance must be a combined total of at least 1" on back of
unit. Do not place any object that can block the ventilation exhaust from
the machine compartment register. Area of equipment must be free of all
combustible materials.
3. Ventilation: The air cooled self contained unit requires a sufficient amount
of cool clean air. Avoid surrounding your unit around other heat generating
equipment and out of direct sunlight. Also, avoid locating in an unheated room
or where the room temperature may drop below 70°F (21°C) or rise above
86°F (32°C).
PART NUMBER PP MNL1705, REV. D (08/23)
SHIP WT
VOLT
AMPS
NEMA
115/60/1
6.0
5-15P
(LBS)
250*

Advertisement

Table of Contents
loading

Summary of Contents for Randell 65348-290

  • Page 1 RETAIN THIS MANUAL FOR FUTURE REFERENCE and liquids in the vicinity of this or any other appliance. NOTICE: Due to a continuous program of product improvement, Randell reserves the WARNING R290 flammable refrigerant in use. Improper installation, right to make changes in design and specifications without prior notice.
  • Page 2: Manual Defrost

    LABEL DIMENSION: 7.5 in x 5.36 in INSTALLATION CHECKLIST Randell has attempted to preset the temperature control to ensure that your unit runs at an optimum temperature, but due to varying ambient conditions, After the final location has been determined, refer to the following checklist prior...
  • Page 3: Maintenance

    If a failure of the equipment is a direct result of any of the Preventative Maintenance guidelines being neglected, the repairs and parts replacements will not be covered If you have questions pertaining to the content in this manual, contact Randell at under warranty.
  • Page 4: Troubleshooting

    S2 Sensor Failure Contact service • Bleed the refrigerant from the high side hose to the low side hose S3 Sensor Failure Contact service • Disconnect the hoses S4 Sensor Failure Contact service • Remove line taps OM-65348-290 SELF-CONTAINED WORK-TOP FREEZER...
  • Page 5: Parts List

    THERMODISC, 2-WIRE, OPEN:70 CLOSE:50 SEO-70-T17 RF CNT1602 THERMISTOR, QT, COIL SENSOR, BLUE, 10' RF CNT1603 THERMISTOR, QTI, AIR SENSOR, BLACK, 10' EL ELM9904 ELEMENT, DEFROST, 120V, 400W, 65000 FREEZER MULLION RF HTR0101 HEATER, HOLD DOWN CLIP 14GA S/S 6.38" LONG OM-65348-290 SELF-CONTAINED WORK-TOP FREEZER...
  • Page 6 CASTER, HEIGHT ADJUSTABLE (6.000" TO 6.812"), PNFG336521A9 HD SHL025 SHELF, 14 x 20-5/8" 1164 HD SHL030 SHELF, 14" x 22" 1158 HD LEG9902 LEG, PRE ASSEMBLED 1750 506 0M0 A41-9900-C HD THR100 THERMOMETER, 4" HANGING HB-120L (S3511-91) N* OM-65348-290 SELF-CONTAINED WORK-TOP FREEZER...
  • Page 7 FAN, AXIAL, 119 x 38mm, OPER/TEMP RANGE -30C-+70C,115V-50/60 RF FAN0703 FAN GUARD, NICKEL CHROME FINISH WIRE 116MM RND RP WRP1703 WRAP. HEAT EXCHANGE 65348-290, .042 X 10' EL SWT1701 SWITCH, ROCKER, 125-250V, 10.1A RF CNT1601 CONTROL, DANFOSS ERC112C, 65348-290, PREPROGRAMMED...
  • Page 8 RP HNG9901 HINGE, DOOR RIGHT HAND SELF CLOSING RP HNG9902 HINGE, DOOR LEFT HAND SELF CLOSING IN GSK9902 GASKET, DOOR 18.57" X 24.25" RP HNG025 HINGE, SPRING LOAD ASSEMBLY RP HNG027 HINGE, BOTTOM L BRACKET W/COLLAR OM-65348-290 SELF-CONTAINED WORK-TOP FREEZER...
  • Page 9: Electrical Schematic

    Electrical Schematic OM-65348-290 SELF-CONTAINED WORK-TOP FREEZER...
  • Page 10: Service Log

    Service Log Model No: Purchased From: Serial No: Location: Date Purchased: Date Installed: Purchase Order No: For Service Call: Date Maintenance Performed Performed By OM-65348-290 SELF-CONTAINED WORK-TOP FREEZER...
  • Page 11 IMPORTANT - À LIRE EN PREMIER appareil ou de tout autre appareil. AVIS : À cause de son programme d’amélioration continue de produit, Randell se AVERTISSEMENT Le réfrigérant inflammable R290 est utilisé. Une réserve le droit d’effectuer sans préavis des modifications à la conception et aux installation, ajustement, modification, service ou entretien inadéquat peuvent...
  • Page 12: Conditions Ambiantes

    1. Assurez-vous que les conduites de réfrigération apparentes ne sont pas déformées, bosselées, et qu’elles ne frottent pas les unes contre les autres. Randell a tenté de prérégler la commande de température pour s’assurer que votre appareil fonctionne à la température optimale, cependant, en raison des conditions 2.
  • Page 13: Entretien

    à votre horaire pour effectuer l’entretien. Pour une liste complète des ASA de Randell, veuillez visiter notre site www.unifiedbrands.net. Randell croit en la qualité des produits qu’il fabrique, c’est pourquoi il offre une ENTRETIEN des meilleures garanties de l’industrie. Nous croyons qu’avec un entretien et une utilisation appropriés, votre investissement sera rentable et que vous allez pouvoir...
  • Page 14: Dépannage

    Contact service • Purger le gaz réfrigérant de la partie supérieure du tuyau vers la partie inférieure tuyau S4 défaillance du capteur Contact service • Débrancher les tuyaux • Enlever les prises de ligne OM-65348-290 CONGÉLATEUR AVEC SURFACE DE TRAVAIL AUTONOME...
  • Page 15: Liste Des Pièces

    THERMISTANCE DE LA SONDE DE TEMPÉRATURE QTI, NOIRE, 10 PI EL ELM9904 ÉLÉMENT DE DÉGIVRAGE, 120V, 400W, MONTANT INTERMÉDIAIRE DU CONGÉLATEUR 65000 RF HTR0101 PINCE DE RETENUE DE L’ÉLÉMENT CHAUFFANT, 14GA S/S 16,2 CM (6,38 PO) DE LONGUEUR OM-65348-290 CONGÉLATEUR AVEC SURFACE DE TRAVAIL AUTONOME...
  • Page 16 CLAYETTE, 35,56 X 52,4 CM (14 X 20-5/8 PO) 1164 HD SHL030 CLAYETTE, 35,56 CM (14 PO) X 56 CM (22 PO) 1158 HD LEG9902 PATTE PRÉASSEMBLÉE 1750 506 0M0 A41-9900-C HD THR100 THERMOMÈTRE SUSPENDU DE 10 CM (4 PO) HB-120L (S3511-91) N* OM-65348-290 CONGÉLATEUR AVEC SURFACE DE TRAVAIL AUTONOME...
  • Page 17 VENTILATEUR AXIAL, 119 X 38MM, GAMME DE TEMPÉRATURES FONCTIONNELLES -30C-+70C, 115V-50/60 RF FAN0703 GRILLE DE PROTECTION, FIL EN NICKEL-CHROME, ROND, 116MM RP WRP1703 ENVELOPPE. DE L’ÉCHANGEUR DE CHALEUR 65348-290, 0,042 X 10 PI EL SWT1701 BOUTON À BASCULE, 125-250V, 10,1A RF CNT1601 COMMANDE PRÉPROGRAMMÉE DANFOSS ERC112C, 65348-290...
  • Page 18 CHARNIÈRE À FERMETURE AUTOMATIQUE DE LA PORTE DROITE IN GSK9902 JOINT D’ÉTANCHÉITÉ DE LA PORTE, 47,17 CM (18,57 PO) X 61,6 CM (24,25 PO) RP HNG025 CHARNIÈRE À RESSORT RP HNG027 SUPPORT INFÉRIEUR EN L DE LA CHARNIÈRE AVEC COLLIER OM-65348-290 CONGÉLATEUR AVEC SURFACE DE TRAVAIL AUTONOME...
  • Page 19: Schéma Électrique

    CONDENSEUR BLEU VENTILATEUR # 2 VENTILATEUR DE L’ÉVAP. # 1 BLEU BLANC VENTILATEUR DE L’ÉVAP. # 2 BLEU BLANC COMPRESSEUR NOIR CHAUFFERETTE AVANT # 1 BLANC NOIR CHAUFFERETTE AVANT # 2 BLANC BLANC OM-65348-290 CONGÉLATEUR AVEC SURFACE DE TRAVAIL AUTONOME...
  • Page 20: Journal D'entretien

    Journal d'entretien N° de modèle : Acheté de : N° de série : Emplacement : Date d'achat : Date d'installation : N° du bon de commande : Pour un appel de service : Date Entretien effectué Effectué par OM-65348-290 CONGÉLATEUR AVEC SURFACE DE TRAVAIL AUTONOME...