Thank you for choosing the REGAL medical diode laser system. REGAL is class 4 laser. Care is required to avoid hazards or injures. Please read the operation manual carefully before operating. If you have further questions which are not answered by...
Fragile – handle with care. Not to be stowed under other cargo. The REGAL should only be transported and stored in its original container to prevent damage. Extreme movements during the transportation should be avoided. The device should avoid any contamination of acid, alkali or caustic material. Protect it from direct exposure under the sun or the rain.
When unpacking, please check whether all the items are inside according to the packing list and save them with care, for them will be in demand when you return the product to reveal If you have any questions, please contact reveal or authorized distributor immediately.
Page 10
3. Safety Tips and Technical Acceptance 3.1 General The “REGAL” is a precise medical laser device and can only be used for medical application. The system has been thoroughly developed and will be thoroughly tested before shipment. To enjoy your product through the lifetime and to protect you and your personal from laser radiation we recommend reading this chapter very carefully.
3.7 Manual Reset Any improper function of the system will immediately cut the electric supply to the laser then “I” position. If the failure shows up repeatedly, please contact reveal or the authorized distributor at once. 3.8 External interlock connector...
Page 13
B type device Refer to operate manual 2011-03-21 Production date Manufacturer REGAL User Operating Manual...
Page 14
3.10 NOHD, National Ocular Hazardous Distance Numerical aperture of Fibre (NA) Fibre diameter (d) Maximum energy (E (Plus margin of error) 8 Hz Frequency at maximum energy x (8Hz x 10s) Pulse_Train Maximum ermissible exposures (MPE) (engl.) Pulse_Train 4 x E –...
“REGAL” will not generate any waste during normal use. If necessary, the REGAL can be disposed according to local policy of conventional electric products.
(2) Color touch screen (3) Fiber and the handpiece (4) Foot switch (5) Power detector panel, safety shutter and the embedded computer control system. 5.2 Front Panel Regal Front Panel: (1) Laser Aperture (6) Alarm Indicator (RED) (2) Key Switch (7) Handpiece Holder...
Page 17
The key should only be carried or be available by the physician who operates the device. The key switch serves as the main system activator. Turning the key switch into “|” position, Attention! REGAL User Operating Manual...
Page 18
5.2.3 Color Touch Screen The LCD touch screen of the unit features high sensitivity and high resolution. Touch the Attention! 5.2.4 Alarm Indicator The alarm indicator will be red when the system alarms. 5.2.5 Laser Emission Indicator The Laser emission indicator will be yellow when the laser is in operation. The action of the indicator is synchronized with the laser.
Page 19
5.2.8 Emergency Stop pressing the emergency stop will immediately stop laser emission. Before restarting, turn as the arrow shows at the knob to bounce up the emergency stop. REGAL User Operating Manual...
5.2.10 Encode Knob is not the same. 5.3 Rear Panel REGA Rear Panel:...
Page 21
There is a red dot on the connector. Insert the footswitch or interlock with the red dot facing upward as the picture shows above. When pulling out the footswitch or interlock, hold in the proper manner. REGAL User Operating Manual...
Operating the Device Attention! 6.1 Introduction To guarantee a proper operation of the device during surgery, the following requirements have to be met: (1) The device has already been plugged into electricity. (2) The safety goggles are available for the people in the room. necessary).
Page 23
For more information, please see chapter 10 “Failure Detection”. Enter the Password “0000” to enter the Speciality screen REGAL User Operating Manual...
Page 24
Select the speciality enter the treatment screen. 6.3 Main Menu...
6.4.1 Set laser output power WW” button, you can set the laser output power conveniently. Also you can use the encode 6.4.2 Select laser emission mode There are altogether 3 emission modes. When selected, the corresponding button will turn green: REGAL User Operating Manual...
Page 26
Attention! 6.4.3 Set laser T on time used to adjust the value. When the desired value is reached, “REGAL” will save the parameter. used to adjust the value. When the desired value is reached, “REGAL” will save the parameter. There are 7 levels of the aiming beam and sound from 0 to 6. If the aiming beam level is 0, it means that the aiming beam is closed and if sound level is zero it means machine is muted.
Page 27
Standby: in this status, the laser power supply is disabled. When you press the footswitch, it Ready: in this status, the laser power supply is enabled. When you press the footswitch, it can send out laser. REGAL User Operating Manual...
Page 28
System information: If you want to learn about the system information, please go to the “Settings” icon in the password interface. REGAL 0.05 6.4.8 Protocol interface...
You can rename the proposals easily, just by tapping the “Rename” button. 6.5 Laser Emission you to wear the safety goggles (protect wavelength is from 800nm to 1700nm). At this time when you press down the footswitch, the laser will emit. REGAL User Operating Manual...
3) Connect the footswitch 3) Footswitch not connect 4) Write down the wrong code, and 4) System is wrong contact reveal Stop the laser and wait for a few Temperature is high minutes Temperature is low Make room temperature more high...
Page 31
To add set power, add test again Aim beam works, no laser diode laser have light Diode laser module is destroyed Contact with reveal 1) Restart the laser to see if alarm still appears Alarm info appears Check the temporary failures REGAL User Operating Manual...
NOTE: 8.2 The Main Unit’s Maintenance “REGAL” is precise medical instrument and should only be maintained by professional technicians authorized by reveal cover should be cleaned by alcohol in advance. (2) Do not touch the screen with hard or sharp materials. Do not scrub the screen with...
Page 34
Diode laser of 650nm, power < 5mW, adjustable Aiming beam brightness. Color LCD touch screen Operation interface Power supply Laser Class Class I, Type B Cooling FUSE Dimensions 450mm 400mm 250mm Weight IPX1 Waterproof level IPX8 Footswitch Waterproof level Safefy Compliance REGAL User Operating Manual...
Need help?
Do you have a question about the REGAL and is the answer not in the manual?
Questions and answers