Blueridge BA16 Series Installation Instructions Manual

Blueridge BA16 Series Installation Instructions Manual

Single stage
Hide thumbs Also See for BA16 Series:

Advertisement

BA13/16 (SINGLE-STAGE) AIR CONDITIONER
This is a safety alert symbol and should never be ignored. When you see this symbol on labels or in
manuals, be alert to the potential for personal injury or death.

Table of Contents

Safety Precautions ......................................................2
Installation ...................................................................2
Electrical Connections .................................................4
Start-Up Procedure......................................................5
System Operation ........................................................6
Homeowner's Information ...........................................9
These instructions are intended as a general guide and
do not supersede national, state or local codes in any
way.
These instructions must be left with the property owner.
NOTE TO INSTALLING DEALER
These instructions and warranty are to be given to the
owner or prominently displayed near the indoor air
handler unit.
Manufactured By
Blue Summit LLC
8201 C National Turnpike
Louisville, KY 40214
507043-04B
INSTALLATION INSTRUCTIONS
This manual must be left with the homeowner for future reference.
NOTE
Save these instructions for future reference
result in hazards to you and others. Installation MUST
conform with local building codes and with the National
Electric Code NFPA 70/ANSI C1-1993 or current edition
and Canadian Electrical Code Part 1 CSA .
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
performed by a licensed professional installer (or
equivalent), service agency or the gas supplier.
*P507043-04B*
Issue 1832
WARNING
WARNING
(P) 507043-04B
Page 1 of 9

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BA16 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Blueridge BA16 Series

  • Page 1: Table Of Contents

    INSTALLATION INSTRUCTIONS BA13/16 (SINGLE-STAGE) AIR CONDITIONER This manual must be left with the homeowner for future reference. This is a safety alert symbol and should never be ignored. When you see this symbol on labels or in manuals, be alert to the potential for personal injury or death. Table of Contents WARNING Safety Precautions ............2...
  • Page 2: Safety Precautions

    These units are designed for use in residential and When passing refrigerant tubes through the wall, seal commercial type buildings. Units should be installed opening with RTV or other silicon-based caulk. with combinations listed in the Air-Conditioning, Heating Avoid direct tubing contact with water pipes, duct work, Products.
  • Page 3 Do not leave the lines open to the atmosphere for any period of time, moisture, dirt and bugs may contaminate the lines. Filter Drier and reliability. If the drier is shipped loose, it must be void, if the drier is not installed. 13/16 SEER Model Liquid Line...
  • Page 4: Electrical Connections

    Follow the vacuum pump manufacturer’s instructions. Allow the pump to operate until the system has been CAUTION evacuated down to 300 microns. Allow the pump to continue running for an additional 15 minutes. Turn If ANY refrigerant tubing is required to be buried by state OFF the pump and leave the connections secured or local codes, provide a 6 inch vertical rise at service to the two (2) service valves.
  • Page 5: Start-Up Procedure

    Start-Up Procedure wires from disconnect through power wiring hole provided Close electrical disconnects to energize system. Set room thermostat at desired temperature. Be sure set point is below indoor ambient temperature. WARNING Set the system switch of the thermostat on COOL and fan switch for continuous operation (ON) or AUTO, as The unit cabinet must have an uninterrupted or unbroken desired.
  • Page 6: System Operation

    Measure indoor air (entering indoor coil) wet-bulb temperature with a sling psychrometer. 350-450 CFM per ton (12,000 Btuh) through a wet coil. Compare superheat reading at service valve with the Refer to indoor unit instructions for methods of determining If unit has a higher suction line temperature than charted temperature, add refrigerant until charted Cooling Cycle Charge Adjustment Procedure temperature is reached,...
  • Page 7 Figure 3. A/C Single Phase Wiring Diagram (single-speed condenser fan) 507043-04B Issue 1832 Page 7 of 9...
  • Page 8 Figure 4. A/C Single Phase Wiring Diagram (multi-speed condenser fan) Page 8 of 9 Issue 1832 507043-04B...
  • Page 9: Homeowner's Information

    Homeowner’s Information Important System Information Periodically, debris should be brushed from the condenser coils. • Your system should never be operated without a clean • Return air and supply air registers should be free from WARNING SHARP OBJECT HAZARD! Regular Maintenance Requirements Condenser coils have sharp edges.