Belco Security DA3000 - Standalone Touch Access Controller Manual

Specifications

Technical parameters

NO Item Value
1 Operating voltage DC 12V±10%
2 Operating current < 100mA
3 Dimensions 120mm×78mm×22mm
4 Weight 110g
5 Ambient temperature 0℃—60℃
6 Relative humidity 20%—80%
7 Storage 1000 users
8 Card type RFID (Mifare optional)
9 Card reading distance 1-10CM

Factory Default

Programming Password 123456 Common Access Password None
Backlight Auto Relay Unlock output 5 Seconds
W26 port Input Security mode OFF
Open mode Card or Access Password
Access Password include Private Access Password (PIN) and
Common Access Password

Light and Sound indicates

Light: red and green

Light Description Access control status
Red light flash every 1 sec(Slow flash) Holding state
Red light is always ON Programming state
Green light is always ON within Open time Unlocking state
Green light flash every 0.5sec (Fast flash) Pending further action

Sound: buzz

Description Indicates
1 short buzz Valid input
3 short buzz Invalid input
1 long buzz Program success
Continuous long buzz Restoring factory programming passwords

Installation Guide

Overview

JP1 terminal

NO Mark Color Function
1 +12V Red Power+
2 GND Black Power-
3 PUSH Blue Low level output
4 OPEN Yellow Door Release
5 BELL Grey Bell
6 BELL White Bell

JP2 terminal

NO Mark Color Function Remark
1 +12V Red Power+
Optional

2 GND Black Power-
3 DATA0 Green WG DATA0
4 DATA1 White WG DATA1
5 NC Brown Relay NC output
6 COM Blue Relay Com output
7 NO Purple Relay NO output

Programming Guide

Detailed Programming Guide

Programming Password Default: 123456, all password can be 3~6 digits

Purpose Operation Remark
Basic
Function



Change Programming Password
# Programming Password # 0 new Programming Password #
New Programming Password #
If Programming Password lost, perform To reset to Factory Programming Password to reset to Factory Default (123456).
Add user card # Programming Password # 1 read card # If add multiple cards, read cards continuously
Set Common Access Password # Programming Password # 21 new Common Access Password # Can only enroll one Common Access Password. Open method: Password #
Delete all users # Programming Password # 40 0000 # Delete all cards and PIN except Common Access Password
Delete user by read card # Programming Password # 41 read card # If delete multi cards, read cards continuously
Advance Function














Add Private Access Password(PIN) # Programming Password # 22 PIN # Can enroll more than 1 PIN, Unlock door method: PIN #
Add card by input card No. # Programming Password # 23 input card No. # Card No. is 10-digit or 8-digit, machine auto-identify
Add multi-card by input card No. zone # Programming Password # 24 input start card No. card Qty # Card Qty is 4-digit (If one-time add twenty cards, input 0020)
Add "card +PIN" # Programming Password # 3 read card PIN # If modify PIN, see How to change PIN (When open mode: card+ PIN)
Delete user by input User ID No. # Programming Password # 42 input User ID No. # About User ID No. see User ID No. explain.
Delete user by input card No. # Programming Password # 43 input card No. # Card No. is 10-digit or 8-digit, machine auto-identify
Delete user by input PIN # Programming Password # 44 input PIN # PIN is 3~6 digits.
Delete all PIN users # Programming Password # 45 1111 # Use to delete PIN users (Do not include Card users and Card +PIN users)
Change Open time # Programming Password # 5 XX # XX can be 2-digit, and the max. is 99. If input 00, the signal output time is 0.2 Secs.
Set Open mode # Programming Password # 6 XX # XX can be 01(only card)/ 02(card or Access Password)/ 03(card+PIN)
Reader setting (Optional) # Programming Password # 6 04 # The machine can be used for reader(W26 output)
Security function Setting # Programming Password # 7 XX # XX can be 01/ 02( Security function OFF/ON) and 03/04(Anti-dismantle alarm OFF/ON)
Anti-dismantle Alarm setting (Optional) Remark: Security Function ON means System would be locked for 5 Minutes if continue to read illegal card or input wrong Access Password for 10 times.
Backlight setting(Optional) # Programming Password # 8 XX # XX can be 01/02/03 (Normal ON / Normal OFF / Auto)
Reset Factory Default # Programming Password # 8 99 # Except Programming Password and Manager Card
Set Manager Card # Programming Password # 91 read MAC read MDC # First read card is Manager Add Card and Second read card is Manager Delete Card.

To reset to Factory Programming Password

(123456)

Step 1. Turn off power and connect bin 2&3 of RST(S1).
Step 2. Turn on power and buzzer gives 3 long buzz with green light flash fast. If need to set Manager Card, now read two empty cards first one as Manager Add Card and Second one as Manager Delete Card with red light flashing and continuous short buzz.
Step 3.Turn off power, disconnect bin2&3 and connect bin 1&2 of RST.
Step 4.Turn on power again.

How to use Manager Card – MAC&MDC

To add a card user in standby mode:

To delete a card user in standby mode:

To delete all users in standby mode:

Remark: User cards can be added or deleted continuously.

User ID No. explain

User ID is auto-generating 4-digit number started at 0001. The number increases with adding user one by one and ignores deleting user. Common Access Password has no ID.

How to change PIN (When open mode: card+ PIN)

After reading card and input corresponding PIN to open the door, within 5 seconds, long press # until the green lights flash fast. and then input , new PIN changed successfully with a long buzz.

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Belco Security DA3000 - Standalone Touch Access Controller Manual

Advertisement

Need Assistance?

Do you have a question about the DA3000 that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents