Download Print this page

Specification - Sealey ROADSTART RS131.V6 Instructions

Emergency power pack 12v 900 peak amps

Advertisement


DO NOT use this product to perform a task for which it is not designed.

DO NOT store the unit in damp or wet locations or where the temperature may exceed 50°C.

DO NOT submerge the unit in water.
DO NOT use whilst under the influence of drugs, alcohol or intoxicating medication.


DO NOT leave the unit in a totally discharged state for an extended period of time as this may result in permanent damage.

DO NOT cross-connect the power leads from the RoadStart to the battery. Ensure that positive is to positive and negative is to
negative. Observe polarity indicator during connection.

Ensure that the unit is fully charged before storage.
1.3.
ELECTRICAL SAFETY (with respect to mains chargers)
R
WARNING! It is the user's responsibility to check the following:
You must check the AC adaptor to ensure that it is safe before using. You must inspect the power supply lead, plugs and all
electrical connections for wear and damage. You must ensure the risk of electric shock is minimised by the installation of
appropriate safety devices. An RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution board.
We recommend that an RCD (Residual Current Device) is used with all electrical products. It is particularly important to
use an RCD with portable products that plug into an electrical supply not protected by an RCCB. If in doubt consult a qualified
electrician. You can obtain a Residual Current Device through your Sealey stockist. You must read and understand instructions
concerning electrical safety.
The Electricity At Work Act 1989 requires all portable electrical appliances, if used on business premises, to be tested by a qualified
1.3.1.
person, using a Portable Appliance Tester (PAT) on a regular basis
1.3.2.
The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of the appliance and
the safety of the appliance operator. If in any doubt about electrical safety, contact a qualified electrician.
1.3.3.
DO ensure that the insulation on all cables and the product itself is safe before connecting to the mains power supply.
1.3.4.
DO ensure that cables are always protected against short circuit and overload.
1.3.5
DO regularly inspect power supply, leads, plugs for wear and damage and power connections to ensure that none are loose.
DO check product voltage is the same as power supply to be used, check that all fused plugs are fitted with the correct capacity fuses.
1.3.6.
2. INTRODUCTION
Composite case with moulded rubber protection, integral battery cable storage and carry handle. LED Battery condition, polarity check, with
audible warning if polarity is reversed, and charge indicators. Features independent on/off switch which allows the positive clamp to be connected
without the risk of sparking and an integral LED work light for use at night. Fitted with two 12V power sockets that will accept any 12V device fitted
with a vehicle accessory socket plug. Also features a USB outlet (5V/1A). Supplied with mains charger.

3. SPECIFICATION

Model No: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RS131.V6
Cold Cranking Amps: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400A
Peak Amps: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 900A
Voltage: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12V
Auxiliary Output:. . . . . . . . . . . . . . . . . . . . . . . . . . . . .5V/1A USB (x1), 12V Vehicle Accessory (x2)
Cable & Clamp Length: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 725mm
Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.6kg
fig.1
Key
1: On/off switch
2: Positive lead
3: Negative lead
4: 12V outlet sockets
5: Negative clamp
6: Positive clamp
7: LED work light
8: USB indicator
9: 5V USB socket
10: Work light/USB selector
11: Charging socket
12: Polarity indicator
13: Battery level lights
14: Battery level check button
© Jack Sealey Limited
Original Language Version
RS131.V6
Issue: 1 - 11/10/18

Advertisement