Use and maintenance manual, models "FLAT - ZENITH - CLASSIC"
3.7
EXAMPLES OF PROPER INSTALLATION
Always refer to the standard UNI 10683 when
product installation has to be carried out by a
qualified professional, who is required to issue the
INSTALLATION CERTIFICATE OF CONFORMITY on
the whole Italian territory. Examples: (A) horizontal
section needed for connection to an existing
flue. Observe a minimum upward slope (3-5%) to
reduce the quantity of ash deposit in the horizontal
section of the pipe - which must not exceed 2m
(1). The existing flue must be inspectable (2).
The installation of the product (B) requires an
insulated flue (3), as the entire smoke pipe has
been mounted outside the building.
Example (C) shows a single-wall smoke duct (4)
for the indoor section. With regard to the part
located in the attic, outside the room where the
generator is installed, it is necessary to install an
insulated section, with double crossing of the slab
and the roof; the passing holes of the pipe must
respect the minimum safety distances indicated
on the labels of the sections of the flue pipe itself,
paying attention to the possible contact with the
material crossed, as is the case with:
• if in contact with concrete, bricks, etc.;
• if in contact with wood, composite materials, etc.
In both cases, insert a suitable roof passage (5)
between the flue and the attic.
It is recommended to check and respect the
data on the flue plate, paying particular attention
to safety distances from combustible materials.
The previous rules also apply to connection holes
drilled on the wall.
In the lower part of the flue pipe, a "T" type
connector (6) with inspection plug (7) has been
fitted for the all the 3 types of installation.
In the upper part of the flue, for all 3 examples,
a windproof chimney pot (8) has been mounted.
For all the 3 types of installations, a grate (9) has
been provided to ensure good oxygenation of
the room where the product has been placed. In
case of hermetically sealed appliance, equipped
with direct outdoor connection of the air-intake
system, a grate is not required.
3.8
DOCUMENTS TO BE ISSUED
After installation, the installer must hand over to
the user the following:
• use and maintenance manual of the appliance
(supplied by the manufacturer);
• technical documents of the accessories used and
subject to maintenance;
• the documentation relevant to the evacuation
system of combustion products;
• System booklet;
• the documentation certifying installation and
functional test;
The useful documentation for the installer's liability
must include:
• a detailed description (also including photographs)
of the presence of other heat generators;
• Declaration of Conformity of the system to
standard (M.D. 37/08);
• general description, or diagram, or photographic
documentation of the changes made to the
system, if intervention was necessary during
installation;
• Use of certified material with the CE mark
(305/2011);
• any other relevant information useful for warranty
purposes;
• date and signature of the installation technician;
NOBIS SRL cannot be held liable in the event of
non-compliance with any installation and startup
standards.
3.9

UNPACKING THE PRODUCT

The packaging is composed of boxes in recyclable
cardboard, according to RESY standards, and
wooden pallets. All packaging materials can be
re-used for similar use or, if necessary, disposed of
as urban waste, in compliance with legislation in
force.
Cut the strap binding the pallet to the packaging
and lift the cardboard; remove the plastic bag
around the product, ensuring it is intact.
The body must always be moved in a vertical
position using trolleys.
Pay particular attention so that the door and its
glass are protected against mechanical impacts
which would compromise their integrity.
If possible, unpack the product near the area
where it will be installed.
11