Sumak ST-66164V Instruction Manual

Air hydraulic riveter

Advertisement

Quick Links

INSTRUCTION MANUAL
ST-66164V
ITEM NO.:
AIR HYDRAULIC RIVETER
ST-66164V-I-2109B-C1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ST-66164V and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sumak ST-66164V

  • Page 1 INSTRUCTION MANUAL ST-66164V ITEM NO.: AIR HYDRAULIC RIVETER ST-66164V-I-2109B-C1...
  • Page 2: Table Of Contents

    SAFETY INSTRUCTIONS ................4 OPERATION INSTRUCTIONS ................ 5 MAINTENANCE ....................7 TROUBLESHOOTING ..................8 INCHES PART LIST FOR ST-66164V TOOL ..........9 List of Figures FIG. 1 CCP-190A RIVET-PULL TOOL ............3 FIG. 2 DETAIL ILLUSTRATION OF CHANGE THE NOSEPIECE, JAW, AND JAW PUSHER.
  • Page 3: Tool Specification

    TOOL SPECIFICATIONS Technical Data Model Of Tool…………………………..……… Dimensions……………………………………... 11.6” X 9.84” X 3.79” (Length X Height X Width) (290mm X 250mm X 96.5mm) Weight…………………………..………..3.26 lbs [1.48 Kgs] Air Inlet………………………………………… 1/4” NPT Recommended Operating Pressure………...… 85 to 95 psi [6 to 6.7 kg/cm2] Air Consumption………………...….
  • Page 4: General Description

    GENERAL DESCRIPTION Rivet-Pull Tool illustrated in Fig. 1 with its pneumatic hydraulic system provides an efficient, lightweight, powerful, and quiet tool for rivet nut installation. It is designed to provide long life and trouble free services. HOOK SPENT MANDREL BOTTLE NOSEPIECE TRIGGER SHUTOFF VALVE...
  • Page 5: Safety Instructions

    SAFETY INSTRUCTIONS DANGER Read this manual and understand all safety instructions before operating the tool. If you have any questions, please contact authorized representatives. Never allow the use of flammable gases (oxygen) as a power source for the tool. Use filtered, lubricated, and regulated compressed air only.
  • Page 6: Operation Instructions

    OPERATION INSTRUCTIONS A. To prepare 1. Following the steps below to install the desired nosepiece: a. Loosen and remove the nosepiece (Index 37 in Figs. 2 & 5), then set up the desired nosepiece (Index 37~37-2 in Figs. 2 & 5) on frame head as shown in Fig.
  • Page 7 B. To operate a. Open the shutoff valve, let the air enter the rivet-pull tool. ※ When use the rivet-pull tool, the shutoff valve must be in the open state, otherwise there was no suction to inhale the rivet. b. Is it make suction switch is it control suction to come, anticlockwise direction it is heavy for suction to, the clockwise suction is diminished to fasten, can close the suction(Index 48 in Figs.3 &...
  • Page 8: Maintenance

    Maintenance The maintenance required when the tool of: pulling strength diminish , it is only Necessary to add ISO VG46 oil or DEXRON III, the operation steps as below: Unscrew and remove the front head(Index 38)turn the tool upside down and well fixed ,then Use spanner remove No.1 parts Remove No.7 parts.
  • Page 9: Troubleshooting

    TROUBLESHOOTING Stop using the tool immediately if any of the following problems occur. Any repairs or replacements must be done by a qualified person or an authorized service center only. PROBLEM CAUSE REMEDY The differen t rivets need to change the compared nosepiece, jaw and jaw pusher.
  • Page 10: Inches Part List For St-66164V Tool

    SUMAKE PNEUMATIC TOOLS 3/16"(4.8mm) Air Hydraulic Riveter (Vacuum Type) ST-66164V Specification: Noise and Vibration: 3/32”, 1/8”, 5/32”, 3/16” Noise Riveting Capacity Vibration (2.4mm, 3.2mm, 4.0mm, 4.8mm) Remark EN ISO 15744 EN ISO 20643 Stroke Length 0.59” (15 mm) Traction Power...
  • Page 11 ST-66164V 3/16"(4.8MM) AIR HYDRAULIC RIVETER ST-66164V-P-2306C-C1...
  • Page 12 ST-66164V 3/16"(4.8MM) AIR HYDRAULIC RIVETER PARTS LIST Description Q'ty Description Q'ty Parts No. Parts No. 66164V-01 Cylinder Cap 37-1 66164V-37-1 Nosepiece 5/32" (Φ4.0) 66164V-02 Rubber Botton 37-2 66164V-37-2 Nosepiece 1/8" (Φ3.2mm) 66164V-03 Air Cylinder Body 37-3 66164V-37-3 Nosepiece 3/32" (Φ2.4mm)
  • Page 13 4F, No. 351, Yangguang St., Neihu District, Taipei City, Taiwan declare in sole responsibility that the equipment Equipment: 3/16"(4.8MM) AIR HYDRAULIC RIVETER (VACUUM TYPE) Model/ Serial No.:ST-66164V to which this declaration applies, complies with these normative documents: Machinery Directive: 2006/42/EC  and conforms to the following EN standard, ...
  • Page 14 RIVETER Original instructions SUMAKE Industrial Co. Ltd.
  • Page 15 Read all these safety instructions before operating this product and save these instructions. The tool has been manufactured in conformity with the instruction of EU machine directive. The EU mark will be considered void in the event of inexpert repairs, the use of non-original parts and in case of non-observance of the safety instructions in the user’s manual. Possible direct or indirect consequential damages are not the responsibility of SUMAKE Industrial co., Ltd.
  • Page 16 Safety precautions for repetitive motions hazards 1. When using a power tool, the operator may experience discomfort in the hands, arms, shoulders, neck, or other parts of the body. 2. While using a power tool, the operator should adopt a comfortable posture. Maintain secure footing and avoid awkward or off-balanced postures.
  • Page 17 General preparation and connection: Before connecting the air hose, apply 4 to 5 drops of SAE 10W-20 (ISO Viscosity Grade 46/32) Hydraulic Oil at the air inlet. Also, every 3 to 4 hours of operation, oiling is necessary. Twist Teflon thread tape to ensure a proper seal air inlet. Then tighten the air coupler into air tool.

Table of Contents