2-3
Front Panel LEDs and Buttons
No.
Name
Power button
1.
with LED
2.
ID Button
(Note)
System
3.
Status
LED
(Note)
HDD Status
4.
LED
LAN 1/2
5.
Active/Link
LEDs
6.
Reset Button
(Note) If your server features RoT function, please see the following section for detail LED behavior.
6
5
RST
L1
L2
Color
Status
Green
On
Green
Blink
N/A
Off
Green
On
On
Amber
Blink
N/A
Off
On
Green
Blink
Amber
On
Green/
Blink
Amber
N/A
Off
The function is disabled.
System Appearance
4
3
2
1
ID
Description
System is powered on
System is in ACPI S1 state (sleep mode)
•
System is not powered on or in ACPI S5 state
(power off)
•
System is in ACPI S4 state (hibernate mode)
Press the button to activate system identification
System is operating normally.
Critical condition, may indicate:
System fan failure
System temperature
Non-critical condition, may indicate:
Redundant power module failure
Temperature and voltage issue
Chassis intrusion
System is not ready, may indicate:
POST error
NMI error
Processor or terminator missing
HDD locate
HDD access
HDD fault
HDD rebuilding
No HDD access or no HDD fault.
Press the button to reset the system.