Service And Adjustments - Craftsman 919.724321 Owner's Manual

Permanently lubricated single stage portable
Table of Contents

Advertisement

Available languages

Available languages

cycles automatically when power
is on. When servicing, you may
be exposed to voltage sources,
compressed air, or moving parts.
Before servicing unit unplug or
disconnect electrical supply to the
air compressor, bleed tank of pres-
sure, and allow the air compressor
to cool.
To Replace or Clean Check
Valve
1.
Release all air pressure from air
tank. See "To Drain Tank" in the
Maintenance section.
2.
Set the On/Auto/Off lever to
"OFF" and unplug unit.
3.
Remove shrouds.
4.
Using an adjustable wrench
loosen outlet tube nut at air tank
and pump. Carefully move outlet
tube away from check valve.
A14411

SERVICE AND ADJUSTMENTS

Risk of Unsafe
Operation. Unit
5.
Using an adjustable wrench
loosen pressure relief tube nut
at air tank and pressure switch.
Carefully move pressure relief
tube away from check valve.
6.
Unscrew the check valve (turn
counterclockwise) using a 7/8"
open end wrench. Note the ori-
entation for reassembly.
7.
Using a screwdriver, care-
fully push the valve disc up and
down. NOTE: The valve disc
should move freely up and down
on a spring which holds the valve
disc in the closed position, if
not the check valve needs to be
cleaned or replaced.
8.
Clean or replace the check valve.
A solvent, such as paint or var-
nish remover can be used to
clean the check valve.
9.
Apply sealant to the check valve
threads. Reinstall the check valve
(turn clockwise).
10. Replace the pressure release
tube. Tighten nut.
11. Replace the outlet tube and
tighten nut.
12. Replace the shroud and air filter.
13. Perform the Break-in Procedure.
See "Break-in Procedure" in the
Operation section.
18- ENG

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save PDF