Download Print this page

zBoost YXC-40K Installation Overview

Advertisement

Quick Links

zBoost
CI: YXC-40K Installation Overview
®
zBOOST INSTALLATION
This YXC-40K zBoost indoor coverage kit provides a complete solution for improving cellular voice and data signal
within buildings up to 40,000 square feet. The kit provides the key components and design elements to allow
professional installation over a wide variety of building conditions with proven technology from zBoost. zBoost indoor
coverage kits use a network of active amplifiers and antennas configured to provide optimum signal strength for
multiple cellular providers while protecting the integrity of the carrier network using patented technology.
OVERVIEW:
1. Connect the system according to the diagram. Customer supplied RG-6 or RG-11 coax will vary in length
according to your particular installation.
2. Orient the two Signal Antennas (YX021 and YX023) with the face of the panel antenna pointing toward the nearest
cell tower. The Signal Antennas should be mounted at least 3 feet away from any metal using the provided YX014
Mounting pole. Ensure that the 18" coax jumper connected to each antenna (YX021 and YX023) is connected to
the correct port on the YX015 combiner (i.e. YX021-CEL connected to CEL port).
3. The YX044-F30 should be placed at the coax entrance to the building and grounded to a suitable connection.
4. The YX841D Network Unit should be located indoors, as close to the antennas as possible, but away from the
other amplifiers. Warning: Do not use this as a Coverage Unit (Part YX842D). If the YX842D and YX841D are
mixed, your zBoost system will not work.
5. Several values of attenuators are included in the kit. The value used will depend upon signal strength and cable
lengths. Ensure that the attenuator connects from the CEL port of one YX015 to the CEL port of the other YX015.
Connect the attenuator on the PCS ports in the same way. A tool to calculate the final value needed can be found
in the Commercial Solutions Division section of our website when logged into your dealer account.
6. Locate each of the eight YX842D Coverage amplifiers and associated YX052 ceiling mount antennas throughout
the desired indoor coverage area. (*Note 110 VAC is required for each YX842D amplifier). Each amplifier and
associated ceiling mount antenna will cover approximately 5,000 sq ft depending on outdoor signal strength.
IMPORTANT: Customer supplied RG-6 coax will vary in length according to your particular installation. The
maximum length of RG-6 coax is indicated on the drawings. Should additional length be required, use RG-11 coax.
The following contents are included in your zBoost system:
(1) YX841D Network
(8) YX842D Coverage
Unit and Power Supply
Unit and Power Supply
OUT
OUT
OUT
OUT
(8) YX052
(2) YX041-F4P
Base Unit Antenna
Splitter
YX021-CEL Outdoor
YX023-PCS Outdoor
Signal Antenna
Signal Antenna
(8) YX030-15W
(6) CCBL-0006
Coax, 18", F(m) to F(m)
Coax, 15', F(m) to F(m)
RG-6 (10 - 150 ft)*
YX043-TNCF
Attenuator Kit
YX044-F30
(16 pieces)
Surge Arrestor
CEL
PCS
SIGNAL ANTENNA COMBINER
OUTPUT
(5) YX015
RG-6 (10 - 150 ft)*
Combiner (diplexer)
YX014
(5) CCBL-0017
J Pipe Mount
Coax, 3", F(m) to F(m)
IN
2-WAY SPLITTER
OUT
OUT
YX041-F2P
(9) YX043-TNCF
Splitter
TNC-F Adaptor
YX021-CEL
YX023-PCS
CCBL-0006
CCBL-0006
CEL
PCS
YX015 Combiner
SIGNAL ANTENNA COMBINER
OUTPUT
RG-6 (10 - 100 ft)*. For longer than 100 feet,
use RG-11
YX044-F30. Ground at building penetration
RG-6 (3 - 6 ft)*
YX841D
110 VAC required for all amplifiers. Keep
this amplifier at least 4 feet away from
YX043-TNCF
other system amplifiers.
CCBL-0017
IN
YX041-F2P-splitter
2-WAY SPLITTER
OUT
OUT
RG-6 (1- 50 ft)*
RG-6 (1- 50 ft)*
YX015 Combiner
CCBL-0017
(Attenuation will vary depending on outdoor
signal strength and cable lengths. See step
5 in the Overview for more information.)
CCBL-0006
CEL
PCS
CEL
PCS
YX015 Combiner
SIGNAL ANTENNA COMBINER
SIGNAL ANTENNA COMBINER
OUTPUT
OUTPUT
RG-6 (1- 50 ft)*
RG-6 (1- 50 ft)*
RG-6 (10 - 150 ft)*
YX041-F4P-splitter
IN
RG-6 (10 - 150 ft)*
RG-6 (10 - 150 ft)*
110 VAC required
for all amplifiers
YX842D
YX030-15W
YX052
RG-6 (10 - 150 ft)*
YX041-F4P-splitter
IN
RG-6 (10 - 150 ft)*
RG-6 (10 - 150 ft)*
110 VAC required
YX842D
for all amplifiers
YX043-TNCF
YX030-15W
YX052
*Long runs of RG-6 cable not included with kit
CHECK YOUR SYSTEM FOR PROPER OPERATION
YXC-40K Works with 800 MHz and 1900 MHz Devices
To verify proper operation of your zBoost system:
1. Apply power to each of the YX842D Coverage amplifiers. Once power is connected, check that the LED light on
each YX842D is a solid green. If the light on any amplifier is solid or flashing red, additional attenuation may be
required. Contact technical support for assistance at 1-800-871-1612.
2. Using your cell phone or a YX699 signal meter, check various areas of your desired indoor coverage area for
improved signal strength.
3. Place a phone call near one of the YX842D amplifiers and verify that you get a flashing green LED light on the
nearest YX842D.
4. If the Signal Light does not flash green, but you are experiencing improved signal strength, your system is still
operating property. If the signal light does not flash green and you are not experiencing improved signal strength,
contact our technical support for assistance at 1-800-871-1612.
Contact zBoost technical support at support@zBoost.com,
or call 1-800-871-1612 for assistance.
TM
Note: Not all parts
shown for YXC-40K
YXC-40K v7

Advertisement

loading

Summary of Contents for zBoost YXC-40K

  • Page 1 YX023-PCS ❾ ❽ zBOOST INSTALLATION CHECK YOUR SYSTEM FOR PROPER OPERATION This YXC-40K zBoost indoor coverage kit provides a complete solution for improving cellular voice and data signal YXC-40K Works with 800 MHz and 1900 MHz Devices CCBL-0006 ⓭ CCBL-0006 ⓭...
  • Page 2 However, there is no guarantee that interference will not occur in a particular installation. If the equipment does cause zBoost. If zBoost cannot reasonably repair or replace the unit then zBoost may, at its sole discretion, refund the price you paid for the product. All harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to products, including replacement products, are covered only for the original warranty period.