Gas pasta cooker

Advertisement

Quick Links

INSTALLATION AND
OPERATION MANUAL
"PASTA MAGIC"
GAS PASTA COOKER
C
WARNING:
IMPROPER INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE PROPERTY DAMAGE, INJURY,
OR DEATH. READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR
SERVICING THIS EQUIPMENT
Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent
using genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been
improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation
instructions provided with the product, or any product that has its serial number defaced, obliterated or removed, or
which has been modified or repaired using unauthorized parts or by unauthorized service agents.
For a list of authorized service agents, please refer to the Garland web site at http://www.garland-group.com.
The information contained herein, (including design and parts specifications), may be superseded and is subject
to change without notice.
Original Document
Document # G_GHD_OM_PASTACUISINE_4607873 – 08/21
US
Bring Your Passion to the Surface
PLEASE READ ALL SECTIONS OF THIS MANUAL
ANDRETAIN FOR FUTURE REFERENCE.
THIS PRODUCT HAS BEEN CERTIFIED AS COM-
MERCIALCOOKING EQUIPMENT AND MUST BE
INSTALLED BYPROFESSIONAL PERSONNEL AS
SPECIFIED.
IN THE COMMONWEALTH OF MASSACHU-
SETTS THISPRODUCT MUST BE INSTALLED BY A
LICENSED PLUMBEROR GAS FITTER. APPROVAL
NUMBER: G-1-07-05-28

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PASTA MAGIC and is the answer not in the manual?

Questions and answers

Summary of Contents for Garland PASTA MAGIC

  • Page 1 Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent using genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation instructions provided with the product, or any product that has its serial number defaced, obliterated or removed, or which has been modified or repaired using unauthorized parts or by unauthorized service agents.
  • Page 2: Important Information

    State of California to cause cancer. Inhalation of carbon monoxide is known to the State of California to cause birth defects or other reproductive harm. GARLAND PASTA COOKERS EQUIPPED WITH LEGS ARE FOR PERMANENT INSTALLATION. FOR MOVEABLE OR PORTABLE INSTALLATION, GARLAND OPTIONAL EQUIPMENT CASTERS MUST BE USED.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS IMPORTANT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . 2 General Information .
  • Page 4: General Information

    CAUTION Parts Ordering and Service Information Caution boxes contain information about actions or In order to assist you quickly, the Garland Factory Authorized conditions that may cause or result in a malfunction of Servicer (FAS) or Service Department representative your system.
  • Page 5: Model Comparison

    Model Comparison QUALIFIED OPERATING PERSONNEL Qualified operating personnel are those who have carefully GPCRB/GPCR: The “Gas Pasta Magic System” consists of a read the information in this manual and have familiarized gas cooker and rinse tank combination. The unit is equipped...
  • Page 6: Installation Instructions

    ” equipment will void the Garland warranty and may result For installations in other than the United States, installers in damage to the equipment or injury to personnel.
  • Page 7: Caster/Leg Installation

    Resolve Radio-TV Interference Problems” helpful. It is prepared by the Federal Communications Commission Pasta Magic cookers are manufactured to use the type of gas and is available from the U.S. Government Printing Office, specified on the rating plate. The rating plate is attached to Washington, DC 20402, Stock No.
  • Page 8: Connection To Gas Line

    The maximum allowable incoming water pressure to the regulator for all units is 80 PSI (56.3 kg/cm2). The Pasta Magic family of gas cookers has been approved for The maximum allowable incoming water temperature use with natural and propane (LP) gas.
  • Page 9: Converting To Another Gas Type

    INSTALLATION INSTRUCTIONS Continued Converting to Another Gas Type NOTE: When using thread compound, use very small amounts on male threads only. Use a pipe thread compound that is not affected by the chemical action of DANGER LP gases (i.e. propane, G31) (Loctite™ PST56765 Sealant is Your cooker is configured at the factory for a specific one such compound).
  • Page 10: Operating Instructions

    OPERATING INSTRUCTIONS Finding Your Way Around the Pasta Cooker Overflow Low-water sensor High-water sensor Temp probe Drain Cook pot Controller Trouble light Drain valve Blower Gas valve Document # G_GHD_OM_PASTACUISINE_4607873 – 08/21...
  • Page 11: Controller

    Controller cleaning the cookpot, the controller display will read LO. The Pasta Magic Controller allows the operator to specify NORMAL WATER LEVEL SENSING, on units configured with a cook time in minutes and seconds, and then initiate the Autofill feature, water is automatically added during or a cooking cycle.
  • Page 12: Operating Instructions

    OPERATING INSTRUCTIONS Continued Operating Instructions 3. After the burners have been lit continuously for at least 90 seconds, observe the burners through the burner Before turning the cooker on, ensure that: viewports. They should display a bright orange-red glow. If a blue flame is observed, or if there are dark spots on a •...
  • Page 13: Boiling Out The Cookpot

    OPERATING INSTRUCTIONS Continued Boiling Out the Cookpot To ensure that the cooker is free of contamination from manufacture, shipping, or handling during installation, the cookpot must be boiled out before first use. 1. Close the drain valve and fill the cookpot with a mixture of cold water and 1 cup of detergent.
  • Page 14: Preventive Maintenance

    PREVENTIVE MAINTENANCE Daily Preventive Maintenance WARNING It is normal for a coating of starch to form on the sensors Do not use deliming solution to clean these units. Use of and temperature probes during operation. If the coating is deliming solution will damage all stainless steel parts. allowed to build-up, it will adversely affect the operation of the equipment.
  • Page 15: Adjusting The Burner Gas Pressure

    Allow it to soak for five DANGER minutes. Rinse the wheel and housing with hot tap Garland recommends that ONLY qualified service water, then dry with a clean cloth. personnel perform this task. 1. Ensure that the gas valve knob is in the OFF position.
  • Page 16: Measuring Flame Current

    PREVENTIVE MAINTENANCE Continued Controller Simmer Mode Adjustment 6. To adjust the burner gas pressure, remove the cap from the gas valve regulator and use a flat tipped screwdriver NOTE: The controller simmer temperature is adjustable to adjust the regulator to obtain the correct pressure. from 185°F to 215°F (85°C to 102°C).
  • Page 17 THIS PAGE INTENTIONALLY LEFT BLANK Document # G_GHD_OM_PASTACUISINE_4607873 – 08/21...
  • Page 18: Operator Troubleshooting

    If your have doubts as to the proper action to take, do not hesitate to call Welbilt KitchenCare or your local Garland Factory Authorized Servicer for assistance. Before calling a servicer or the Welbilt KitchenCare HOTLINE (844-724-2273): •...
  • Page 19: Operator Troubleshooting Guides

    OPERATOR TROUBLESHOOTING Continued Operator Troubeshooting Guides Problem Probable Causes Corrective Action A. Ignition module lockout (the A. Turn the controller OFF. Open the burners failed to light within 4 control panel by removing the seconds). screws in the upper corners. If there are two ignition modules, check for Indicator: Red trouble light on blown 2-amp fuses and replace as...
  • Page 20 OPERATOR TROUBLESHOOTING Continued Problem Probable Causes Corrective Action A. Dirty water level sensors. A. A. Remove the probe block cover and clean the sensors using a Scotchbrite™ or similar pad and a solution of detergent and water. NOTE: Do not use deliming solution. B.
  • Page 21 Notes Document # G_GHD_OM_PASTACUISINE_4607873 – 08/21...
  • Page 22 Notes Document # G_GHD_OM_PASTACUISINE_4607873 – 08/21...
  • Page 23 THIS PAGE INTENTIONALLY LEFT BLANK Document # G_GHD_OM_PASTACUISINE_4607873 – 08/21...
  • Page 24 KitchenCare® aftermarket parts and service. Welbilt’s portfolio of award-winning brands includes Cleveland™, Convotherm®, Crem®, Delfield®, fitkitchen®, Frymaster®, Garland®, Kolpak®, Lincoln®, Manitowoc®, Merco®, Merrychef® and Multiplex® . Bringing innovation to the table • welbilt .com ©2021 Welbilt Inc. except where explicitly stated otherwise. All rights reserved.

Table of Contents