Download Print this page

M-system M5XADS Instruction Manual page 3

Advertisement

EXTERNAL VIEWS
■ LEFT VIEW
OUTPUT RANGING
The internal DIP switch setting is required to select output types before setting a precise output range using PC Configurator
Software (model: M5CFG).
For detailed information on the PC configuration, refer to the M5CFG users manual.
Table 1. Input range
Input range
0 - 50 mA DC
-1000 - +1000 mV DC
-10 - +10 V DC
Table 2. Output type
Output Type
0 – 20 mA
-5 – +5 V
OFF
-10 – +10 V
OFF
■ FRONT VIEW
Output Setting
DIP SW
Input 1
SW2-1
ON
OFF
OFF
1
2
ON
OFF
ON
ON
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
■ RIGHT VIEW
Power Indicator LED
Configurator Jack
SW2-2
SW2-3
OFFF
ON
ON
OFF
OFF
OFF
SW1
3
4
OFF
OFF
ON
OFF
OFF
ON
M5XADS
Input Setting
DIP SW
Input 2
SW2-4
OFF
ON
OFF
5
6
ON
OFF
OFF
ON
OFF
ON
EM-2777 P. 3 / 4

Advertisement