Advertisement

Quick Links

TABLE OF CONTENTS

2.1 Connecting With Stereo Connector ............................................................ 3
2.2 Connecting With Pigtail Adapter ................................................................ 5
2.3 Viewing Sensor Data .................................................................................. 5
2.4 Changing Sensor Units ............................................................................... 7
2.5 Changing Digital Sensor SDI-12 Address ................................................... 9
2.6 Sensor-Specific Functionality ................................................................. 10
....................................................................................................... 11
3.1 Specifications .......................................................................................... 11
3.2 Components ............................................................................................ 12
....................................................................................................... 13
4.1 Maintenance ............................................................................................ 13
4.2 ZSC Firmware Update .............................................................................. 13
4.3 Troubleshooting ....................................................................................... 15
4.4 Customer Support.................................................................................... 17
4.5 Terms and Conditions .............................................................................. 18
Appendix A. Compliance Certifications ....................................
................................................................................................................. 21
.............................................................................................. 1
................................................................................................... 3
i
18325-01
4.2023
19

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SDI-12 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for METER SDI-12

  • Page 1: Table Of Contents

    2.1 Connecting With Stereo Connector ............3 2.2 Connecting With Pigtail Adapter ..............5 2.3 Viewing Sensor Data .................. 5 2.4 Changing Sensor Units ................7 2.5 Changing Digital Sensor SDI-12 Address ........... 9 2.6 Sensor-Specific Functionality ..............10 3. System ....................... 11 3.1 Specifications ..................
  • Page 3: Introduction

    Thank you for choosing the ZSC Bluetooth Sensor Interface from METER Group. ® The ZSC is a hardware accessory to support METER ZENTRA system sensors. The ZSC pairs wirelessly with iOS and Android mobile devices through the ZENTRA Utility Mobile app to display sensor measurement data and metadata (firmware version, serial number, etc.).
  • Page 4 INTRODUCTION Use the In-App Tutorial to become familiar with the app screens and capabilities prior to connecting to a sensor (Figure 3). Figure 3 ZENTRA Utility Mobile In-App Tutorial...
  • Page 5: Operation

    Please read all instructions before operating the ZSC to ensure it performs to its full potential. PRECAUTIONS METER instruments are built to the highest standards, but misuse, improper protection, or improper installation may damage the sensor and possibly void the manufacturer’s warranty. Before using the ZSC, follow the recommended user instructions and arrange proper protections to safeguard the instrument from damage.
  • Page 6 OPERATION Figure 5 Plug sensor cable into ZSC Press the button on the ZSC. Confirm that the LED on the ZSC begins blinking blue. Open ZENTRA Utility Mobile app on the mobile device. The Connect screen will appear. ZENTRA Utility Mobile will search for and display nearby Bluetooth-enabled ZENTRA devices (Figure 6).
  • Page 7: Connecting With Pigtail Adapter

    2.2 CONNECTING WITH PIGTAIL ADAPTER For METER sensors to be used with non-METER loggers, the connection may have been stripped and tinned. To connect these sensors back to the ZSC or other METER loggers, a pigtail-to-stereo adapter cable will be needed. Contact...
  • Page 8 OPERATION Figure 8 Measurement screen If the sensor is not automatically recognized, choose the sensor from the dropdown list (Figure 9). Figure 9 Select Sensor menu...
  • Page 9: Changing Sensor Units

    The displayed sensor units can be changed at any time through the ZENTRA Utility Preferences menu. NOTE: Device Defaults in the Preferences menu do not apply to the ZSC. Defaults apply to METER data loggers only. Select Preferences at the bottom of the Measurement screen (Figure 10).
  • Page 10 OPERATION Figure 11 Select measurement of interest Scroll through the units to highlight the desired units (Figure 12). Figure 12 Changing preferred units...
  • Page 11: Changing Digital Sensor Sdi-12 Address

    METER digital sensors have the default SDI-12 address of 0. If the sensors are being used with a non-METER logger using SDI-12 protocol on a bus, use the ZSC and the ZENTRA Utility Mobile app to change the sensor SDI-12 address. See the individual sensor integrator guide for more information about the SDI-12 protocol in the sensors.
  • Page 12: Sensor-Specific Functionality

    OPERATION 2.6 SENSOR-SPECIFIC FUNCTIONALITY The ZSC can also perform some sensor-specific functionalities. Consult the specific sensor manual for details on how to use these functionalities. • ATMOS 41 pyranometer calibration coefficient changes after funnel component replacement (ATMOS 41 Manual) • ATMOS 22/41 Wind Speed Zero (ATMOS 41 Manual)
  • Page 13: System

    Android operating system (OS). iOS 10 or greater Sensor Input Port 3.5-mm stereo plug connector (supports METER analog, digital, or pulse sensors) NOTE: A pigtail-to-stereo adapter cable can be ordered to connect sensors with pigtail wiring (Section 2.2). PHYSICAL SPECIFICATIONS...
  • Page 14: Components

    SYSTEM Battery Life Approximately 6 months with daily use Enclosure UL94 HB, RoHS-compliant ABS plastic COMPLIANCE EM ISO/IEC 17050:2010 (CE Mark) Additional compliance information is in APPENDIX 3.2 COMPONENTS The ZSC has a single button to wake the ZSC and enable Bluetooth connections (Figure 14). There is also an LED to indicate the unit status: •...
  • Page 15: Service

    NOTE: If the ZSC will be stored for a prolonged period (greater than 2 weeks), remove the batteries. 4.2 ZSC FIRMWARE UPDATE METER releases firmware updates for ZSC to improve product performance. ZENTRA Utility Mobile will automatically check the firmware version upon connecting the ZSC. If a newer firmware version exists, ZENTRA Utility Mobile will display an Update ZSC firmware banner will show up at the top of the app (Figure 15).
  • Page 16 SERVICE Press the Update ZSC firmware banner. Additional instructions will appear on screen (Figure 16). Figure 16 Notes prior to updating firmware Carefully read and follow the instructions. When ready, press Start Update. The screen will automatically advance through the process. The app will display that the firmware was successfully updated (Figure 17).
  • Page 17: Troubleshooting

    Figure 17 Firmware update comfirmation Select Close. 4.3 TROUBLESHOOTING Table 1 lists common problems and their solutions. Table 1 Troubleshooting the ZSC Problem Possible Solutions Ensure location services are enabled on the Android device. Ensure Bluetooth is enabled on the device. ZSC cannot connect to Check the Android OS, and confirm that it is v4.3 or higher.
  • Page 18 SERVICE Table 2   Troubleshooting the ZSC (continued) Problem Possible Solutions Ensure that the sensor is supported by the ZSC (only METER-brand sensors are supported). Sensor measurements Ensure the sensor connector is fully inserted in the ZSC. will not show up on app Ensure proper sensor wiring if using the pigtail-to-stereo adapter.
  • Page 19: Customer Support

    Figure 19 Send Feedback 4.4 CUSTOMER SUPPORT NORTH AMERICA Customer service representatives are available for questions, problems, or feedback Monday through Friday, 7:00 am to 5:00 pm Pacific time. Email: support.environment@metergroup.com sales.environment@metergroup.com Phone: +1.509.332.5600 Fax: +1.509.332.5158 Website: metergroup.com...
  • Page 20: Terms And Conditions

    NOTE: For products purchased through a distributor, please contact the distributor directly for assistance. 4.5 TERMS AND CONDITIONS By using METER instruments and documentation, you agree to abide by the METER Group, Inc. Terms and Conditions. Please refer to metergroup.com/terms-conditions...
  • Page 21: Appendix A. Compliance Certifications

    This device contains IC ID 8017A-MDBT42Q A.3 EUROPEAN UNION The ZSC is tested to comply with CE mark requirements. A full CE declaration of conformity for the ZSC is available on request from METER.
  • Page 22 SERVICE A.4 JAPAN R 201-160496 A.5 TAIWAN 本產品內含射頻模組:ID 編號 CCAM16LP1180T2...
  • Page 23: Index

    LED 4, 12 Preferences 7 sensor-specific module 10 updating firmware 13–15 maintenance 13 operating system compatibility Android 1, 11, 15 iOS 1, 11, 15 pigtail-to-stereo adapter 5 SDI-12 address 9 sensor measurements connecting 3–5 storage 11 units 7–9 view 5–6 specifications 11–14...

Table of Contents