Advertisement

Quick Links

PENKO Engineering B.V.
Your Partner for Fully Engineered Factory Solutions
Omega QuickStart manual

Advertisement

Table of Contents
loading

Summary of Contents for PENKO Omega

  • Page 1 PENKO Engineering B.V. Your Partner for Fully Engineered Factory Solutions Omega QuickStart manual...
  • Page 2: Table Of Contents

    Connecting a loadcell ..............................4 Connecting a laptop ................................ 5 Connecting to the Factory network ..........................6 First power up.................................. 6 Connecting to the Omega ............................... 6 Ethernet..................................6 USB....................................6 Using Easy Setup to calibrate weighers ........................10 Next steps ..................................14...
  • Page 3: System Overview

    Unused slots are covered by a dummy module. CONNECTING POWER The Omega system uses a 24VDC nominal power supply. The applied voltage should be between 18 and 36Volts. Two power connections are provided. Both connections are wired identically to provide power to the next unit...
  • Page 4: Connecting A Loadcell

    Omega QuickStart manual CONNECTING A LOADCELL Each ADC+DIO or ADC+AIO module has two loadcell connections. The loadcell connects as following:...
  • Page 5: Connecting A Laptop

    Omega QuickStart manual CONNECTING A LAPTOP A laptop for initial setup can be connected to the USB3 connection of the CPU module. This requires a USB-A to Mini USB-B cable. Alternately, a laptop can be connected to Ethernet 2.
  • Page 6: Connecting To The Factory Network

    CONNECTING TO THE OMEGA ETHERNET When the laptop is connected to the Ethernet 2 port, the Omega will supply an IP address. Open your web browser (Edge, Chrome, Safari or Firefox) and type the address 10.1.2.1. This will open the Omega web interface.
  • Page 7 Omega QuickStart manual The default login is: Username: administrator Password: administrator Then click LOGIN After successful login the dashboard is shown: Click on “My Omega” to show an overview of the installed components.
  • Page 8 Omega QuickStart manual Click on “option cards overview” To shows a quick overview of all available channels. All weight, input output and status indicators are live values.
  • Page 9 Omega QuickStart manual This example contains: • dual loadcell and digital io module • Digital I/O module • Analog I/O module Only the loadcell inputs are used to show a weight. When a weigher is shown as “------” the following things can be wrong: •...
  • Page 10: Using Easy Setup To Calibrate Weighers

    Omega QuickStart manual USING EASY SETUP TO CALIBRATE WEIGHERS Now click on the “SETTINGS” for the “Dual Channel Loadcell Digital Outputs(1-1-1)” to start the setup for channel 1 of the first card. The display tab shows that this channel has no valid weight “-------”...
  • Page 11 Omega QuickStart manual This tab shows the weight as “cccccc” which indicates the weigher is not correctly calibrated. The Weigher filters tab allows fine tuning the weigher for different uses. Under “Filter preset selector” several standard use cases can be selected which fill in the appropriate parameters.
  • Page 12 Omega QuickStart manual The Calibration tab is used to do a simple two-point calibration. The signal is at 0.0031mV which is close to 0mV. When a weight is applied to the loadcell this number will increase. The maximum loadcell output will be 20mV.
  • Page 13 Omega QuickStart manual When the two points are too close together in either weight or signal, the message “Gain overflow” will be shown. After a few seconds the gross will show the actual weight and gross x10 shows the higher resolution internal weight before rounding.
  • Page 14: Next Steps

    Return to “Dashboard->Option cards overview”, there the correct weight values are now shown: NEXT STEPS The Omega system is modular and programmable for any weighing and PLC function. More features for each module are available under “Settings->Advanced setup”. To use this please read “7600M1082-EN-R9 Manual Omega”...
  • Page 15: Updating The Omega Firmware

    The CPU module can be updated from the ”tools”menu. Then click “System update”. The update omega menu can be used to update the omega CPU Module. To start the update process, press the UPLOAD FILE button. Only files with the extension “.swu” are supported, e.g. “omega_update_img.swu”.
  • Page 16 To start updating the CPU image press START UPDATE. A pop-up appears to confirm the update. When confirmed the update process starts and the progress is shown. Older version Version 1.0.8.9.0.1 and higher Updating the omega can take up to 5 minutes. Do not leave the page and wait till the update is finished. Older version...
  • Page 17 Omega QuickStart manual Version 1.0.8.9.0.1 and higher When finished a message appears to indicate that the update is finished. After confirming the page will be reloaded. If the update is not done after 6 minutes then the PC might have refused the connection. Disconnect...
  • Page 18 Omega QuickStart manual After a successful updated the browser returns to the system update page. Under Dashboard->My Omega the new version number is shown. Now the cards can be updated. Click on “Tools->Card update”. Then press “Upload firmware” In this example we select the “OmegaDualLoadcellDigital_V1.0.6.9.0.14.pip” file on our PC.
  • Page 19 Omega QuickStart manual Press “UPLOAD FIRMWARE” again. Now select the “OmegaIODigital_V1.0.6.9.0.14.pip” file on our PC. After processing, the orange version number shows that this card has an older version firmware and can be updated. Select the Digital I/O module(s) and click “Update”. Checking the box in the column header will select all cards of this type The file is uploaded from the CPU to the card and after the update “succeeded”...
  • Page 20 About PENKO At PENKO Engineering we specialize in weighing. Weighing is inherently chemically correct, independent of consistency, type or temperature of the raw material. This means that weighing any kind of material guaranties consistency and thus, it is essential to sustainable revenue generation in any industry.

Table of Contents