INSTRUCTIONS
Phase Dimmer

IMPORTANT

TO PREVENT ELECTRICAL SHOCK, POWER SHOULD BE TURNED OFF AT THE FUSE BOX BEFORE INSTALLATION.
WARNINGS and CAUTIONS:
To avoid risk of fire and electrical shock, products shall be installed in accordance with electrical code and regulations.
The product shall be used together with an air-break switch.
Cut off the power at the circuit breaker or fuse before installation.
After installing the dimmer, it's recommended to set the minimum brightness level to make bulbs turn on immediately and
the dimmer with maximum dimming range.
If you're not clear about any content of the instructions, please consult the licensed electrician.
Switch to the leading mode when the inductive load is used.
To avoid the risk of overheating and possible damage to the equipment, do not use the product to control the receptacle,
motor-operated appliance or a transformer-supplied appliance.
Product should only be used with compatible dimmable LED, CFL, incandescent or halogen products.
When connecting multiple products with a single dimmer, do not mix product types. All products shall be either dimmable
LED, CFL or incandescent products. Using the same type of products will enhance dimmer performance.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) This device must accept any interference received, including interference that may
cause undesired operation.

WHAT'S IN THE BOX

Base Plate
Dimmer (1 pcs)
(1 pcs)
5PIN Wiring
2PIN Wiring
Terminal (2 pcs)
Terminal (3 pcs)
XDIM
Jumper Wire
(1 pcs)
Face Plate
Mounting Screws
(1 pcs)
(2 pcs)
Connection Wire (5 pcs)

TOOLS NEEDED

5mm Philips Screwdriver
Electrical Tape
Electrician Knife
Test Pencil
Pliers
Ruler

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XDIM and is the answer not in the manual?

Questions and answers

Summary of Contents for RAB XDIM

  • Page 1 INSTRUCTIONS Phase Dimmer XDIM IMPORTANT TO PREVENT ELECTRICAL SHOCK, POWER SHOULD BE TURNED OFF AT THE FUSE BOX BEFORE INSTALLATION. WARNINGS and CAUTIONS: ● To avoid risk of fire and electrical shock, products shall be installed in accordance with electrical code and regulations.
  • Page 2 INSTRUCTIONS Phase Dimmer BASIC OPERATION ● To exit programming mode, press and hold the On/Up and On/Up Paddle Off/Down Paddle for 3 seconds. The dimmer will automatically exit programming mode after 1 minute without operation. Brightness Indicator Status Indicator Off/Down Paddle Switch Switch ●...
  • Page 3 INSTRUCTIONS Phase Dimmer MULTI-GANG INSTALLATION DERATING INSTALLATION (cont’d) Single-Gang Double-Gang Triple-Gang Rating Rating Rating 120 Vac, 120 Vac, 120 Vac, 60 Hz, 60 Hz, 60 Hz, 500 W Tungsten 400 W Tungsten 300 W Tungsten 300 W CFL/LED/ 300 W CFL/LED/ 300 W CFL/LED/ 3-Way Electronic...
  • Page 4 INSTRUCTIONS Phase Dimmer INSTALLATION (cont’d) 6. Install the wall panel ● Connect the face plate to the installed base plate and gently push it until it clicks into place. Place the base plate over the installed dimmer and secure ● it using provided screws.
  • Page 5 INSTRUCTIONS Phase Dimmer WIRING (cont’d) 2. 3-Way (neutral and hot wire) Wiring Scheme 3 (dimmer line side) Wiring Scheme 4 (dimmer load side) Green Green screw screw Ground Copper Brass screw screw Jumper Brass screw Copper screw Jumper Silver screw Common terminal Black screw Silver screw...

Table of Contents