9. TROUBLE SHOOTING
If the machine does not start, check the compression of the engine and the spark from the spark plug.
Depending on the symptoms that you notice, you can discover the probable cause and solve the problem.
The cylinder's
The spark plug
compression is
is works
normal
YES
YES
Lack of
compression
The engine
does not rotate
Probable cause
No fuel in the tank
The gasoline filter is dirty
There is water in the fuel
YES
The fuel used isn't correct
The carburetor is dirty
The spark plug pipe isn't
connected correctly
No
The spark plug is dirty
The engine switch does not work
The spark plug is loose
The piston and its segments are
YES
The cylinder is grated
Engine seizure
worn
36/108
Corrective action
Fill fuel tank with fuel
Clean the filter
Replace fuel
Change the fuel with one with
proper octane
Send your machine to a service
technician
Connect it
Clean the spark plug
Send your machine to a service
technician
Tighten it
Send your machine to a service
technician
Send your machine to the
service technician
Send your machine to the
service technician