1. Liability for defects
Please read this information very carefully:
Liability for defects can only be accepted if the following rules
and the instructions for installation are complied with.
Provided appropriate CLEARPOINT
the filter elements are replaced once a year, the purchaser of
the compressed-air membrane dryer shall be entitled to claim
remedy of defects within 2 years from date of invoice.
BEKO shall not be liable for damage due to improper or incor-
rect use, wear, storage or other actions by the purchaser or
third parties.
This applies in particular to wearing parts.
2. Temperature
There must be no danger of frost at the place of installation; the
temperatures at the place of installation and of the compressed
air should be between +35 and + 140 °F.
2
Important information • Indicaciones importantes
6
6
5
filters are being used and
®
5
4
6
7
1
3. Filters
Please observe the relevant filter requirements (see page
8 - 9):
Dirt particles, oil residues and liquid condensate have to be
safely retained.
This requires the provision of a CLEARPOINT
filter (0.01 µm). With high dirt loads or large amounts of conden-
sate, it will be necessary to install a CLEARPOINT
(1 µm) in addition and, where appropriate, a W water separator.
Note: The filter elements need to be replaced once a year.
Caution: maintenance works must be carried out only when
the device is pressureless!
4. Pipe between filter and membrane dryer
The membrane dryer must be located directly downstream
of the last CLEARPOINT
condensate formation. If a connection has to be installed be-
tween the filter and the DRYPOINT
be made of non-corroding material! Note: Do not use any
galvanized pipes or fittings between filter and membrane
dryer (corrosion)!
5
7
S super fine
®
F fine filter
®
filter in order to avoid renewed
®
MDe device, this must
®
DRYPOINT
MD economy series
®

Advertisement