Pool & spa cartridge filter

Advertisement

Quick Links

INSTALLATION AND
OPERATION MANUAL
ZXC-SERIES
Pool & Spa Cartridge Filter
WARNING
FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and
qualified on pool equipment in accordance with the latest applicable version of AS3633, along with
any other applicable local or council codes/standards. Before installing this product, read and follow
all warning notices and instructions that accompany this product. Failure to follow warning notices
and instructions may result in property damage, personal injury, or death.
Improper installation and/or operation will void the warranty. Improper installation and/or operation
can create unwanted hazards which can cause serious injury, property damage, or death.

Advertisement

Table of Contents
loading

Summary of Contents for Zodiac ZXC Series

  • Page 1 INSTALLATION AND OPERATION MANUAL ZXC-SERIES Pool & Spa Cartridge Filter WARNING FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified on pool equipment in accordance with the latest applicable version of AS3633, along with any other applicable local or council codes/standards.
  • Page 2 Or scan the QR code to go directly to the registration page. NEW ZEALAND WARRANTY: For full warranty terms and conditions and to register your warranty, visit www.zodiac.co.nz/warranty and complete your details. Or scan the QR code to go directly to the registration page.
  • Page 3: Table Of Contents

    Page 3 ZXC-SERIES™ | Installation and Operation Manual Table of Contents Section 1. Important Safety Instructions ....4 Section 2. General Information ......5 Introduction .
  • Page 4: Important Safety Instructions

    Water temperature for test must NOT EXCEED 38°C (100°F). Limit test to 24 hours. After test, visually check system to be sure it is ready for operation. Notice: These parameters apply to Zodiac equipment only. For non-Zodiac equipment, consult equipment manufacturer.
  • Page 5: General Information

    Introduction diatomaceous earth as the filter medium. Instead, the filter contains filter elements which are easily Congratulations on the purchase of your Zodiac removed for cleaning or replacement. ZXC-series cartridge filter. The ZXC-series filters are made to last by utilising the best quality Dirty water flows into the filter tank through the materials available.
  • Page 6: Zxc-Series Specifications And Dimensions

    Page 6 ZXC-SERIES™ | Installation and Operation Manual ZXC-Series Specifications and Dimensions MAX. MAX. MAX. FILTER 4 HR 6 HR SHIPPING FILTER REPLACEMENT FLOW FLOW WORKING PUMP SIZE MODEL NO. AREA TURN OVER TURN OVER WEIGHT MODEL ELEMENT CODE RATE RATE PRESSURE (KG)
  • Page 7: Installation Instructions

    Make sure all the parts are included in the product Inlet Fittings package. If you have a problem with the filter or the parts, contact Zodiac or the retailer for g. Outlet Fittings technical assistance. h. Drain Cap Assembly (rear)
  • Page 8: Installation

    Page 8 ZXC-SERIES™ | Installation and Operation Manual Installation must be blocked using the blanking cap supplied with the product. 1. The cartridge filter must be installed on a NOTE: Both inlets may be used in an optional clean, stable and level base. configuration (second tail union not included, 2.
  • Page 9 Page 9 ZXC-SERIES™ | Installation and Operation Manual 9. Each inlet is fitted with a water deflector. 11. Assemble the pressure gauge with front and These deflectors must remain in place to rear casings (Figure 9). prevent damage to the filter due to high- speed water flow from the pump (Figure 7).
  • Page 10: Start-Up And Operation

    Page 10 ZXC-SERIES™ | Installation and Operation Manual Section 4. Start-Up and Operation Drain Outlet Inlet Pump Check ZXC-Series Valve Filter Heater Valve Valve Pool Return From Pool Figure 11. Basic Pool Plumbing 6. Open the suction and return line valves (if 1.
  • Page 11: Maintenance

    (Australia) replacement. www.zodiac.co.nz/find-a-dealer (New Zealand) Performing the maintenance checks below will help to identify parts that have worn and require Filter Cartridge Cleaning/...
  • Page 12 Page 12 ZXC-SERIES™ | Installation and Operation Manual NOTE: NEVER LOOSEN THE LOCKING RING WHEN NOTE: Do not use high powered water jets to clean the elements, which may cause damage. Using THE PUMP IS ON! a garden hose with nozzle will do the job safely. 8.
  • Page 13 Page 13 ZXC-SERIES™ | Installation and Operation Manual tank until you will hear a “click” sound when the locking tab has engaged (Figure 18). Close Locking Tab Figure 18. Closing the Locking Ring 12. Start the system by following the procedures outlined in Section 4 “Start-Up and Operation”...
  • Page 14: Troubleshooting

    Section 6. Troubleshooting 1. For a list of common problems and solutions see the Troubleshooting Guide below. 2. Zodiac recommends that you call a qualified service technician to do any work on the filter/pump system. For technical service, in Australia please call 1300 763 021, in New Zealand please call 0800 807 665.
  • Page 15 Page 15 ZXC-SERIES™ | Installation and Operation Manual NOTES...
  • Page 16 Fluidra NZ Ltd 13 Douglas Alexander Parade Rosedale, Auckland 0632 NZBN: 942 903 181 70759 0800 807 665 | Zodiac.co.nz ©2022 ZODIAC® is a registered trademark of Zodiac International, S.A.S.U., used under license. This document is subject to change without notice. H0786900_REVB...