WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR
MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE
INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
Please call the
For Service on Your Gas Griddle:
Service Department and ask for contact information
for your local service company.
3560 NW 56th Street
Fort Lauderdale, FL 33309
Tel.: 786.600.4687 / Toll Free: 844.218.8477
Fax.: 786.661.4100
5659 Royalmount Avenue
Montreal, Qc, Canada H4P 2P9
Tel.: 514.737.9701 / Toll Free: 888.275.4538
Fax.: 514.342.3854 / Toll Free: 877.453.8832
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ikon ITG24 and is the answer not in the manual?

Questions and answers

Summary of Contents for MVP ikon ITG24

  • Page 1 INSTALLATION & OPERATION MANUAL Gas Countertop Thermostat Griddle Models: ITG24 , ITG36 , ITG48 , ITG60 WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT. For Service on Your Gas Griddle: Please call the Service Department and ask for contact information...
  • Page 2 This manual contains important safety instructions which must be strictly followed when using this equipment. Please retain this manual for future reference. Instructions must be posted in a prominent location. All safety precautions must be taken in the event the user smells gas.
  • Page 3: Installation

    INSTALLATION UNPACKING This griddle was inspected before leaving the factory. The transportation company assumes full responsibility for safe delivery upon acceptance of shipment. Check for possible shipping damage immediately after unpacking. If the griddle is found to be damaged, save the packaging material and contact the carrier within 5 days of delivery.
  • Page 4: Flue Connections

    If disconnection of the restraint is necessary, turn off the gas supply before disconnecting. Reconnect the restraint prior to turning the gas supply on and returning the griddle to its installation position. Casters are only supplied on a griddle stand. If the griddle is moved for any reason the griddle should be re-leveled (see LEVELING in this manual).
  • Page 5: Propane Gas Conversion

    PROPANE GAS CONVERSION This griddle is shipped from the factory equipped with fixed burner and pilot orifices for natural gas operation. The burner and pilot orifices required to convert the griddle to propane gas are shipped with the griddle in the shipping packaging.
  • Page 6: Operation

    OPERATION The griddle and its parts are hot. Use care when operating, cleaning or servicing the griddle. BEFORE FIRST USE Remove all packing material and protective plastic from surfaces of the unit. Before leaving the factory, the griddle plate is coated with protective coating as a rust inhibitor. Remove this film when the griddle plate is being cleaned prior to its first cooking use.
  • Page 7: Cleaning The Griddle

    When zone cooking, it is suggested that you start with your lowest temperature setting at either side of the griddle, increasing the zone temperature as you move up the zone line. These zone cooking guidelines will vary depending on product temperatures, size and shape. This guide should be adjusted to suit your product and operational cooking preference.
  • Page 8: Maintenance

    ADJUSTMENTS CALIBRATION 1. Each thermostat controls a 12” zone of the griddle. Using a Surface Probe temperature measurement device, observe the temperatures at the center points of the cooking zones. These points are located by starting 6” from the side splash (left or right) and every 12”...
  • Page 9: Pilot Adjustment

    LEVELING griddle must be level (side-to-side and front-to-back) during operation to ensure proper performance. Improper leveling can result in uneven temperature distribution, cold spots, and possibly damaged components. Place a level on the griddle. Adjust legs by turning the bullet feet at the bottom of each leg. Using pliers or a crescent wrench, turn the feet counter-clockwise to increase height, and clockwise to decrease height until leveling is achieved.
  • Page 10 Conversion Kit Instructions Gas Countertop Thermostat Griddle Models: 24” 36” 48” 60” Thermostat Controlled: WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction.
  • Page 11 Before installing the included convertible Pictured is the plastic insert. Pull off insert from regulator, unscrew the octagon cap. You can read octagon cap and reverse the plastic insert (NAT) on the plastic insert attached to the head of position so that the L.P. position is attached to the cap;...
  • Page 12: Limited Warranty

    Limited Warranty IKON warrants to the original purchaser of new equipment that said equipment, when installed in accordance with our instructions within North America and subjected to normal use, is free from defects in material or workmanship for a period of 1 year. The labor warranty is one year from original installation or 18 months from actual factory shipment date whichever date occurs first.

This manual is also suitable for:

Ikon itg36Ikon itg48Ikon itg60

Table of Contents