Julius Marine S145 LED User Manual

Led lock and bridge signal lantern

Advertisement

Quick Links

User Manual
LED LOCK AND BRIDGE
SIGNAL LANTERN
S145 LED
Version 07 / 2023

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S145 LED and is the answer not in the manual?

Questions and answers

Summary of Contents for Julius Marine S145 LED

  • Page 1 User Manual LED LOCK AND BRIDGE SIGNAL LANTERN S145 LED Version 07 / 2023...
  • Page 2: Table Of Contents

    Terms ..........4 lantern S145 LED and enable professional maintenance.
  • Page 3: Limitation Of Liability

    LIMITATION OF SAFETY SAFETY Opening sealed surfaces will invalidate the warranty / guarantee claims against LIABILITY INSTRUCTIONS the manufacturer. Furthermore, any Safety instructions for maintenance, assembly and repair work unauthorised conversions and modifications All technical information, data and to the signal lantern are not permitted for Before cleaning, maintenance and repair Safety instructions classify situations as instructions for the operation and...
  • Page 4: Technical Data

    TECHNICAL DATA SETUP AND ≈14.5 VDC. Until then, the intensity of the day mode will be used. The intensity in night FUNCTION mode can be adjusted in four stages. The signal switches back from night mode to DIMENSIONS, WEIGHT AND ENVIROMENT Functional description day mode when the supply voltage exceeds Dimension without lens hood...
  • Page 5: Composition

    Front view of LED insert Assignment of DIP switches monitoring switches off the signal after approx. 5.5 minutes in the event of an error. (standard version S145-LED) In the de-energized state, error states are SETTING FUNCTION not saved. lock signal Diagnosis Signal shutdown on LED error →...
  • Page 6: Assembly

    ASSEMBLY Electrical connection of the lock Assignment of DIP switches signal lantern (special variant S145-LED SW-1.0.5) In order to fasten the lock signal lantern SETTING FUNCTION (1) to the lock signal group (2), the three The connecting cable must be wired supporting bolts (3) must first be mounted according to the assignment below.
  • Page 7 Electrical connection ASSIGNMENT OF THE CONNECTING CABLE Service number Function operating voltage +24 V operating voltage 0 V GN / YE (3) Equipotential bonding Plus signal voltage Lantern On Minus signal voltage lantern on Plus signal voltage night reduction Minus signal voltage night reduction Output error collector Output error emitter load resistor (optional)
  • Page 8: Installation

    APPENDIX A simple soapy solution is recommended. Problem 1 Site of installation The electronics only switch off the S145 LED when more defective strands than specified Warning (DIP switches) have been detected. The signal system mast for mounting SPARE PARTS...
  • Page 9 Julius Marine GmbH Industriestraße 15 • 18069 Rostock • Germany T +49 381 25295140 • vertrieb@julius-marine.com Member of the International Association of ISO 9001 Lighthouse Authorities certified...

Table of Contents