Download Print this page

Huawei SU2000L-CN Quick Manual page 3

Advertisement

1. Connect the AC output power cable to the AC connector.
Three-Core Cable (L, N, and PE)
Two-Core Cable (L and N)
2. Connect the AC connector to the AC output port.
3. Check the route of the AC output power cable.
Installing the DC Input Power Cable
3.4
1. Assembling the DC Connector
using metal cold forming contacts
Positive metal terminal
Ensure that the cable will not
Negative metal terminal
be extracted after crimped.
using metal stamping forming contacts
Positive metal terminal
Ensure that the cable will not
Negative metal terminal
be extracted after crimped.
2. Connecting the DC Input Power Cable
Pull the DC input power cable
back to ensure that it is
connected securely.
To remove the AC connector from the
SUN2000L, perform the operations in
reverse order. The right figure shows
how to remove a plug insert.
Positive connector
Negative connector
Pull the DC input power cable
back to ensure that it is
connected securely.
Positive connector
Negative connector
Pull the DC input power cable
back to ensure that it is
connected securely.
1. Ensure that the PV string is well insulated to ground.
2. The metal contacts supplied with the DC connectors are either cold forming contacts or
Click
stamping forming contacts. Crimp the metal cold forming contacts using crimping tool
H4TC0001 (Amphenol). Crimp the metal cold stamping contacts using crimping tool
H4TC0002 (Amphenol). Choose the crimping tools that fit the metal contact types. Do not
mix up the tools.
3. The SUN2000L DC input voltage must always be lower than or equal to 600 V DC.
4. Before installing the DC input power cable, label the cable polarities correctly to ensure
correct cable connections.
5. Use the positive and negative connectors supplied with the SUN2000L.
6. If polarity of the DC input power cable is reversed and the DC switch is ON, do not turn off
the DC switch immediately or unplug positive and negative connectors. The device may be
damaged if you do not follow the instruction. This damage is not covered under any
warranty or service agreement. Wait until the solar irradiance declines at night and the PV
string current reduces to below 0.5 A, and then turn off the DC switch and remove the
positive and negative connectors. Correct the string polarity before reconnecting the string
to the SUN2000L.
3
Click
Click
Ensure that the
Ensure that
cables are correctly
the locking nut
connected.
is secured.
Ensure that the
Ensure that
cables are correctly
the locking nut
connected.
is secured.

Advertisement

loading

This manual is also suitable for:

Su2000l-3ktl-cnSu2000l-4ktl-cnSu2000l-5ktl-cn