INSTALLATION MANUAL OF FASCIA PANEL
Thank you very much for purchasing our product.
Before using your unit, please read this manual carefully and keep it for future reference.
Models
SDV5-01P/02P/03P has neither human body sensing function nor Wi-Fi.
.
I. Precautions
Ask a professional installation company to install the air conditioner, so as to ensure the
installation quality.
To prevent condensation, the joints of the panel need to be sealed and wrapped with
protection sponge, and metal parts such as screws shall not be exposed.
Ensure that the ceiling opening hole sizes are accurate.
The following phenomena are normal and do not indicate a fault.
Description
(1) Due to high humidity and the temperature difference between the air inlet and outlet, cold air may form
White mist is discharged from
white mist.
the panel
(2) When the mode is switched from defrosting to heating, moisture may be discharged in the form of mist.
(3) When the humidifier operates, the steam may form mist after meeting cold air and then be discharged.
The panel generates low
(1) Squeak from natural expansion or contraction of plastic parts.
noises
(2) The louvers may generate low friction sound when they are rotating.
(1) When the unit operates in "cooling" mode in a relatively humid environment (relative humidity
Condensation may occur on
higher than 80%), condensation may occur on the surface of the panel and water may drip.
the surface of the panel and
(2) When the humidifier operates too long, condensation may occur on the surface of the panel and
water may drip
water may drip.
(1) The panel is not equipped with an infrared human sensor.
(2) Wearing thick clothes, other heat sources present in the room, any objects blocking the infrared
Avoid People/Blow on People
is unresponsive
human sensor or falling within the dead zone of the infrared human sensor, may affect the accuracy
and actual effect of smart eye detection.
Louver is perpendicular to the
In a mode other than heating, the panel may automatically adjust the louver angle to ensure the best
panel and it is impossible to
effect of humidification. At this time, the lover angle cannot be customized.
adjust louver operating angles
After clicking Light Off, the
After pressing the OFF button, the panel indicator will automatically turn off after 15s without
panel indicator is still on
operation, please wait patiently.
II. Description of Panel Parts
Upper and lower louvers (automatic)
Embedded left and right louvers
(automatic)
Remote control
Digital display
receiving window
tube
Air outlet
panel
Display box
Temperature and error display
Remote control reception and
infrared human sensor
Timer
Running
Infrared
Defrosting
indicator
indicator
human sensor
indicator
Running indicator: it is on when the power is turned on, off when the power is turned off, and
flashes slowly while in standby mode.
Defrosting indicator: When defrosting or anti-cold wind protection is enabled, the indicator is on.
Timer indicator: When the timing function is on, the indicator is on.
Digital display: In Cool or Heat mode, the digital display shows the set temperature. In Fan mode,
it displays the indoor temperature. In separate humidification mode, it displays the set humidity.
When an error occurs, it displays the error code (see the IDU manual for the error definitions).
When the above indicators are set to be always on via the remote controller or wired controller,
operating indicator and digital display will be steady on, the timer indicator will be steady on during
the timed period, and defrosting indicator will be on when the unit defrosts. When the above
indicators are set to be always off via the remote controller or wired controller, operating indicator,
digital display and timer indicator will be on after the corresponding instruction is received, and will
be off after 15s, and defrosting indicator will not be lit when the unit runs in defrost mode.
III. Applicable Models
Air outlet panel
01
DAP IDU series: 17-36
Applicable model
SDV5-01P/02P/03P series panels areapplicable for small-sized VRF IDUs;
Note: The upper table lists the models of DAP series duct IDUs that support arc-fin
evaporator.
IV. List of Components
Air outlet panel
1 pcs
MODELS: SDV5-01P, SDV5-02P, SDV5-03P
Installation methods and other precautions
Cause
The non-humidifying unit is not equipped with humidification
tubes and the corresponding frames
02
DAP IDU series: 45-56
DAP IDU series: 71
Instruction
Cross recessed head screw
6 pcs
1 pcs
V. Installing the Panel
1. Structure and external dimensions (see Figure 1 and Table 1)
M X Ø 3.2
Model
A
01
705
507
02
925
727
03
1145
947
2. To install the panel, the reserved opening hole sizes for the ceiling are shown in Figure 2,
Table 2, and Table 3.
Air outlet panel
Refrigerant
pipe
Drainage
pipe
Humidification
Indoor air
tube
outlet flange
I
C
A (ceiling opening width)
Model
01 series Panel
02 series Panel
03 series Panel
Model
Applicable IDU (01 series)
Applicable IDU (02 series)
Applicable IDU (03 series)
03
Confirm the ceiling opening position to ensure that the distance from the ceiling to the front
of the unit body is ≥80 mm;
Confirm the ceiling opening position to ensure that distance from the opening hole to the
top of the ceiling is ≥35 mm;
Check whether the ceiling opening size, and the position of the air outlet of the IDU and the
ceiling opening meet the requirements specified in Figure 2.
Check whether the strength of the ceiling for panel installation is appropriate. If the strength
is weak, reinforce the openings to achieve sufficient installation strength.
Check whether the IDU is parallel to the ceiling.
3. Install the air outlet panel.
3.1 Installation method 1: Directly fix the air outlet panel onto the reinforced wooden support of the ceiling
with flat head screws.
3.1.1 Position of the screw holes on the air outlet panel:
Make panel fixing screws symmetrically distributed at the
upper and lower sides. The 01 series panel has 2 holes each
on the top and bottom, and the 02 and 03 series panels have
3 holes each on the top and bottom. All panels have 1 hidden
hole on the left, right, top and bottom, which can be selected
according to actual needs.
Version: 16123000003013 V.A
A
B
G
F
E
L
K
J
C
Figure 1
B
C
D
E
F
G
H
646
41.5
192
199.5
/
42
866
75.5
205
165
238
42
1086
107
268
229
235
42
Ceiling
Ceiling
≥ 80 (distance from the ceiling to the
front of the unit body)
F
(At this point, the panel frame is over 10 mm
away from the air outlet of the unit.
The distance threshold is 56 mm, but the panel
needs to directly face and be inserted into the air
outlet of the unit.)
IDU electric control board
D
Figure 2
A
B
650 to 660
150 to 156
870 to 880
150 to 156
1090 to 1100
150 to 156
H Humidifier I Humidifier J Humidifier
F
G
740
350
193.5
62
960
350
193.5
62
62
1178
350
193.5
CAUTION
Figure 3
150
D
I
H
N X Ø 5.5
19
Table 1 (Unit: mm)
I
J
K
L
M
N
94
250.5
78
/
3
4
81.5
240
240
81.5
4
5
113
318.5
319
113
4
5
≥35 (distance
from the opening
Indoor air
hole to the top
outlet flange
of the ceiling)
Table 2 (Unit: mm)
C
D
E
0 to 10
0 to 10
0 to 9
0 to 10
0 to 10
0 to 9
0 to 10
0 to 10
0 to 9
Table 3 (Unit: mm)
H
I
J
29
69.5
64.5
17
29
69.5
64.5
17
29
69.5
64.5
17

Advertisement

loading

This manual is also suitable for:

Sdv5-01pSdv5-02pSdv5-03p