INSTALLATION INSTRUCTIONS FOR
PRESSURE SWITCH PCL KIT (569000689)
Item
No.
Part No.
1
560002361
Board Circ Prod Delivery
2
560004158
Chip Micro EPROM Main
3
560002360
Board Circ Oper Interface
4
560006424
Switch Press Syr 30-37 PSI
5
560005312
Fitg T 7/16-20 x 1/8-FPT
6
560002318
Fitg Push PI4512F4S .375 x .25
7
560006985
Harn Adaptor Press Switch
8
560002388
Tube Prod .250 I.D. x 22-1/2"
9
560002389
Tube Prod .250 I.D. x 20-1/2"
10
560002339
Clip Flow Bend .375 O.D. Tube
11
4417
Clip Lock .375 O.D. Push-in Fitg
12
690945000
Tie Cable
1. Obtain wakeup time, sleep time, defrost times, and viscosity settings from current setup.
2. Disconnect power (unit may have to be pulled from wall to access electrical outlet).
3. Shut off syrup supply by shutting down CO
4. Remove left side, front access and rear panel.
5. Remove No. 1 cylinder syrup inlet line and No. 1 syrup flow sensor assembly (leftmost if facing unit).
6. Install new syrup inlet line (2 flavor OC unit), or connect existing line with tubing elbow and cable tie (2 and
4 flavor standing units) to pressure switch assembly (see Figure 1). Assemble locks onto pressure switch
assembly and reconnect electrical harness paying close attention to maintaining wiring integrity. Switch is
supplied with adapter harness to retrofit existing wiring (wires to be attached to "C" common and "NC" nor-
mally closed. Note: some parts will be left over.
7. Repeat steps 5 and 6 for No. 2, 3 and 4 syrup inlet lines and syrup flow sensor assemblies.
8. Remove existing main control board EPROM chip using an EPROM extraction tool. Install EPROM taking
great care not to misalign pins or cause damage to chip. Note: wearing ground strap is stronly recom-
mended to protect board from electrostatic discharge. Take care to put each connector back in its
proper location.
9. Remove existing No. 1 cylinder product delivery board. Install new product delivery board (using ground
strap). Take care to put each connector back in its proper location.
10. Repeat step 9 for product delivery boards No. 2, 3 and 4.
569000338
IMI CORNELIUS INC g One Cornelius Place g Anoka, MN 55303-6234
Telephone (800) 238-3600
Table 1. Loose-Shipped Parts
. Bleed CO
2
Page 1 of 2
Facsimile (800) 535–4231
Name
from inlets to BIB pumps.
2
Qty.
2
1
1
2
2
4
2
1
1
2
4
2
Revised: October 9, 2003
January 23, 2002

Advertisement

loading

Summary of Contents for Cornelius 569000689

  • Page 1 IMI CORNELIUS INC g One Cornelius Place g Anoka, MN 55303-6234 Telephone (800) 238-3600 INSTALLATION INSTRUCTIONS FOR PRESSURE SWITCH PCL KIT (569000689) Item Part No. 560002361 Board Circ Prod Delivery 560004158 Chip Micro EPROM Main 560002360 Board Circ Oper Interface...
  • Page 2 Reconnect BIB connectors and verify that soldouts clear. 15. Replace side, front access and rear panels. 16. Pack circuit boards into the protective packaging from the replacement boards for return to IMI Cornelius. Scrap flow sensors, syrup inlet lines that were removed and any leftover parts.