M8015 2337EN 11 September 2023 Installation and operation manual OilonCooling Ck Read these instructions carefully before installation, use, or maintenance...
1 Introduction 1.1 Safety notice and warnings Read these instructions carefully before installation, commissioning, operation, or maintenance of the device. The given instructions must be followed. Throughout this manual, the following symbols are used to point out very important information: Use special caution.
Use only fuses with the correct rating. Do not push items into the air inlet or outlet when the cooling unit is in operation, as this may result in an injury or damage to the equipment. Do not direct the air flow directly towards people. To avoid slipping, keep floor surfaces dry, and seal off or report any leaks that you detect.
Page 7
Removing the packaging Remove the cardboard packaging from around the product. Check the unit for transportation damage. If there is damage, report the damage immediately to the carrier who delivered the unit. M8015 2337EN 5 (20)
2 Installation 2.1 Installing cooling unit Place the cooling unit as high as possible. Cold air flows downwards. If you bring the pipes to the unit through a wall behind the unit, create a passthrough for the pipes. The dimensions required for locating the pass through are indicated on the cooling unit mounting plate.
Installing mounting hardware inside the mounting box When using screws instead of threaded bars to fasten the unit, install mounting supports inside the box. The cooling unit can be fastened to the mounting box either with threaded bars or screws. When using threaded bars to fasten the cooling unit, fasten installation supports to the roof of the box.
Pipe connections, Ck9 Pos. Item Bleed valve Brine out, 3/4" Brine in, 3/4" Condensate drain Condensate tray installation The condensate tray ensures that any condensate from pipe joints is led back into the unit, preventing moisture damage to any surrounding structures. 1.
Page 11
Two-pipe system Power supply for valve actuator Protective earth M8015 2337EN 9 (20)
3 Operation 3.1 Remote control Press only one button at a time. Pressing two or more buttons simultaneously may cause a malfunction. The cooling unit will beep when it has received a signal from the remote control. If the signal does not reach the unit for some reason, there will be no beep. Layout Pos.
3.2 General functions Power On/Off To turn the unit on or off, press the Power On/Off button. When switched on, the unit will operate with the settings shown on the remote control’s screen. Screen brightness adjustment To change the screen brightness, press the DIM button. Keylock To lock the remote control keys, press and hold the DIM button (with the key icon next to it) for two seconds.
3.5 Adjusting room temperature Set the room temperature with the arrow buttons. Available temperature range: 18–30 °C. The set room temperature will be shown on the remote control screen. 3.6 Operating modes To scroll between different operating modes, press the Mode button repeatedly. Mode Description COOL...
Setting the timer to switch the unit on 1. Press the timer On button. The time and the text ‘ON’ will start flashing. 2. Set the start time with the arrow buttons. ● Pressing an arrow button will move the time 10 minutes forwards or backwards. To browse through numbers faster, keep the arrow button pressed.
3.11 Quiet function When using the Quiet function, the fan will run in power saving mode (at minimum speed). Activate or deactivate the Quiet function by pressing the Quiet button. ● The function is available in COOLING, HEATING, and AUTO mode. ●...
4 Maintenance 4.1 Tasks at the start and end of the heating season At the start of the cooling season ● Install new batteries in the remote control. ● Check that the cooling unit is installed correctly. ● Check that the cooling unit’s air flow is free of obstructions. ●...
4.3 Cleaning the cooling unit Carefully clean the air outlet and fan. If the air outlet or fan are dirty, clean with a moist towel. If necessary, use mild detergent. Dry with a dry cloth. Do not use solvents or polishing compounds for cleaning. 4.4 Troubleshooting Problem Cause/corrective action...
5 Technical data 5.1 Technical data Cooling capacity, kW* 4.250 10.8 Max. input power, fan, W Coefficient of performance** 80–200 200–400 Cooled floor area, m Weight, kg Placement Ceiling Ceiling *Cooling capacity in recommended installation conditions, brine inlet temperature: +7 °C, indoor temperature: +27 °C.
5.4 Terms of sale and warranty SUOMEN LÄMPÖPUMPPUTEKNIIKKA OY’S TERMS OF SALE AND WARRANTY FOR PRODUCTS IN THE OILONCOOLING SERIES General In these general terms of sale and warranty, ‘the Supplier’ refers to Suomen Lämpöpumpputekniikka Oy (Business ID: 0511150-0, “the Supplier”), ‘the Customer’ to the company, entity, or person who has entered into this contract or to whom the order confirmation has been addressed (“the Customer”), and ‘Products’...
Page 22
event. Transport damages are not covered by the warranty. The warranty does not cover issues caused by incorrect installation at the place of use or installation contrary to the installation or operation manual, or issues resulting from repair, modification, or installation of Products by some other party than the manufacturer or a maintenance company authorized by the manufacturer.