Download Print this page

Meggitt Whittaker C327598 Installation And Operation Manual

Pressure transducer

Advertisement

Quick Links

NOTICE: PROPRIETARY INFORMATION OF WHITTAKER CONTROLS, INC., A BUSINESS UNIT OF MEGGITT PLC.
THE INFORMATION CONTAINED IN THIS DOCUMENT IS DISCLOSED IN CONFIDENCE. IT IS THE PROPERTY OF
WHITTAKER CONTROLS, AND SHALL NOT BE USED, DISCLOSED TO OTHERS, OR REPRODUCED IN WHOLE
OR IN PART WITHOUT THE EXPRESS WRITTEN CONSENT OF WHITTAKER CONTROLS. IF CONSENT IS GIVEN
THIS NOTICE SHALL APPEAR IN ANY SUCH REPRODUCTION.
Operation Manual
PRESSURE TRANSDUCER
SPOOL ASSEMBLY
Installation and
CLASS 600
PART NUMBERS:
C327598-1
C327599-1
REVISION 1.1 – 12/01/2003
C327598
C327599
C327600

Advertisement

loading
Need help?

Need help?

Do you have a question about the Whittaker C327598 and is the answer not in the manual?

Questions and answers

Summary of Contents for Meggitt Whittaker C327598

  • Page 1 C327599-1 C327600 NOTICE: PROPRIETARY INFORMATION OF WHITTAKER CONTROLS, INC., A BUSINESS UNIT OF MEGGITT PLC. THE INFORMATION CONTAINED IN THIS DOCUMENT IS DISCLOSED IN CONFIDENCE. IT IS THE PROPERTY OF WHITTAKER CONTROLS, AND SHALL NOT BE USED, DISCLOSED TO OTHERS, OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN CONSENT OF WHITTAKER CONTROLS.
  • Page 2 WHITTAKER CONTROLS, INC. A MEGGITT PLC COMPANY INSTALLATION AND OPERATION MANUAL PRESSURE TRANSDUCER SPOOL ASSEMBLY C327598 C C327599 C C327600 LIST OF EFFECTIVE PAGES On a revised page, the portion of text or illustrations affected by the change is indicated by a vertical line in the outer margin of the page.
  • Page 3 WHITTAKER CONTROLS, INC. A MEGGITT PLC COMPANY INSTALLATION AND OPERATION MANUAL PRESSURE TRANSDUCER SPOOL ASSEMBLY C327598 C C327599 C C327600 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS! This manual contains important instructions that should be followed during installation and operation of the Pressure Transducer Spool Assembly.
  • Page 4 WHITTAKER CONTROLS, INC. A MEGGITT PLC COMPANY INSTALLATION AND OPERATION MANUAL PRESSURE TRANSDUCER SPOOL ASSEMBLY C327598 C C327599 C C327600 GIVE CLEANERS SPECIAL CARE ! Keep cleaners in special polyethylene bottles or in safety cans and in minimum quantities. Discard soil- ed cleaning rags into safety cans.
  • Page 5 WHITTAKER CONTROLS, INC. A MEGGITT PLC COMPANY INSTALLATION AND OPERATION MANUAL PRESSURE TRANSDUCER SPOOL ASSEMBLY C327598 C C327599 C C327600 ! Make sure that all of the electrical wiring is properly terminated. Make sure that all of the wire terminals are securely connected.
  • Page 6 WHITTAKER CONTROLS, INC. A MEGGITT PLC COMPANY INSTALLATION AND OPERATION MANUAL PRESSURE TRANSDUCER SPOOL ASSEMBLY C327598 C C327599 C C327600 INTRODUCTION Purpose of Manual This technical manual contains instructions for Installation and shop maintenance of the Pres- sure Transducer Spool Assembly (spool). This manual is intended to provide information in suf- ficient detail to permit proper installation of the equipment.
  • Page 7 WHITTAKER CONTROLS, INC. A MEGGITT PLC COMPANY INSTALLATION AND OPERATION MANUAL PRESSURE TRANSDUCER SPOOL ASSEMBLY C327598 C C327599 C C327600 Symbols and Abbreviations Symbols and abbreviations used in this technical manual are as follows: American Wire Gage Centigrade (Celsius) Direct current...
  • Page 8 WHITTAKER CONTROLS, INC. A MEGGITT PLC COMPANY INSTALLATION AND OPERATION MANUAL PRESSURE TRANSDUCER SPOOL ASSEMBLY C327598 C C327599 C C327600 Table 1. Characteristics/Specifications Applications ......... . Gas Turbine Engine Fuel Systems Service Fluid .
  • Page 9 WHITTAKER CONTROLS, INC. A MEGGITT PLC COMPANY INSTALLATION AND OPERATION MANUAL PRESSURE TRANSDUCER SPOOL ASSEMBLY C327598 C C327599 C C327600 DESCRIPTION AND OPERATION Description (Refer to Figure 1) A. The Pressure Transducer Spool Assembly (spool) consists of a straight pipe section with bolt flanges.
  • Page 10 WHITTAKER CONTROLS, INC. A MEGGITT PLC COMPANY INSTALLATION AND OPERATION MANUAL PRESSURE TRANSDUCER SPOOL ASSEMBLY C327598 C C327599 C C327600 Figure 1. Pressure Transducer Spool Assembly (Sheet 1 of 3) INDUSTRIAL PRODUCTS GROUP Revision 1.1 12/01/2003 Page 8...
  • Page 11 WHITTAKER CONTROLS, INC. A MEGGITT PLC COMPANY INSTALLATION AND OPERATION MANUAL PRESSURE TRANSDUCER SPOOL ASSEMBLY C327598 C C327599 C C327600 Figure 1. Pressure Transducer Spool Assembly (Sheet 2 of 3) INDUSTRIAL PRODUCTS GROUP Revision 1.1 12/01/2003 Page 9...
  • Page 12 WHITTAKER CONTROLS, INC. A MEGGITT PLC COMPANY INSTALLATION AND OPERATION MANUAL PRESSURE TRANSDUCER SPOOL ASSEMBLY C327598 C C327599 C C327600 Figure 1. Pressure Transducer Spool Assembly (Sheet 3 of 3) INDUSTRIAL PRODUCTS GROUP Revision 1.1 12/01/2003 Page 10...
  • Page 13 WHITTAKER CONTROLS, INC. A MEGGITT PLC COMPANY INSTALLATION AND OPERATION MANUAL PRESSURE TRANSDUCER SPOOL ASSEMBLY C327598 C C327599 C C327600 Table 2 Leading Particulars Service Fluid ............Natural Gas Applications P/N C327598 and C327598-1 .
  • Page 14 WHITTAKER CONTROLS, INC. A MEGGITT PLC COMPANY INSTALLATION AND OPERATION MANUAL PRESSURE TRANSDUCER SPOOL ASSEMBLY C327598 C C327599 C C327600 INSTALLATION General This section contains information on installation of the spool assembly in the fuel gas system. Installation Position the pressure sense port for convenient connection to the pressure sense monitoring line.