RECOMMENDED INDICATIONS
- Restoration of Class III, V and limited Class I cavities.
- Restoration of primary teeth.
- Core build up.
- Cases where a radiopaque restoration is required.
- Geriatric applications.
- As a base or liner.
CONTRAINDICATIONS
- Pulp capping.
- In rare cases the product may cause sensitivity in some people. If any such reactions are experienced, discontinue the use of the product and refer to a physician.
DIRECTIONS FOR USE
Powder / Liquid Ratio (g/g) | 0.33 / 0.10 |
Mixing Time (sec.) | 10" |
Working Time (min., sec.) | 3'15" |
Light Curing Time (sec.) | 20" |
Depth of Cure (A2) (mm) | 1.8 |
Test conditions:
Temperature (23 +/-1°C)
Relative humidity (50 +/-10%)
ISO 9917-2: 1998 (E) (Light-activated cements) (Type I)
USE
- CAVITY PREPARATION
- Prepare tooth using standard techniques. Extensive mechanical retention is not necessary. For pulp capping, use calcium hydroxide.
- Wash and dry but DO NOT DESICCATE.GC CAVITY CONDITIONER is recommended to remove the smear layer (Fig. 1).
![GC CORPORATION - Fuji II LC CAPSULE - USE - Step 1 USE - Step 1]()
- CAPSULE ACTIVATION AND MIXING
- Before activation, shake the capsule or tap its side on a hard surface to loosen the powder (Fig. 2).
![GC CORPORATION - Fuji II LC CAPSULE - USE - Step 2 USE - Step 2]()
- To activate the capsule, push the plunger until it is flush with main body (Fig. 3).
![GC CORPORATION - Fuji II LC CAPSULE - USE - Step 3 USE - Step 3]()
- Immediately place the capsule into a metal GC Capsule Applier and click the lever once (Fig. 4). The capsule is now activated.
![GC CORPORATION - Fuji II LC CAPSULE - USE - Step 4 USE - Step 4]()
Note:
The capsule should be activated just before mixing and used immediately. - Immediately remove the capsule and set it into a mixer (an amalgamator) and mix for 10 seconds at high speed (+/-4,000 RPM) (Fig. 5).
![GC CORPORATION - Fuji II LC CAPSULE - USE - Step 5 USE - Step 5]()
- RESTORATIVE TECHNIQUE
- Immediately remove the mixed capsule from the mixer and load it into the GC Capsule Applier.
- Click twice to prime the capsule then syringe (Fig. 6).
![GC CORPORATION - Fuji II LC CAPSULE - USE - Step 6 USE - Step 6]()
The working time is 3 minutes 15 seconds from start of mixing at 23°C (73.4°F). Higher temperatures will shorten working time.
Note: - To adjust the direction of the nozzle, hold the applier with the capsule towards you and turn the capsule body.
- To remove the used capsule, push the applier release button. Twist the capsule and pull upwards.
- Remove surface moisture but DO NOT DESICCATE.
- Extrude cement directly into preparation (Fig.7). Avoid air bubbles.
![GC CORPORATION - Fuji II LC CAPSULE - USE - Step 7 USE - Step 7]()
- Form the contour and place a matrix if required.
- Light-cure for 20 seconds using a suitable visible light curing device (470nm wavelength) (Fig. 8). Place light source as close as possible to the cement surface.
![GC CORPORATION - Fuji II LC CAPSULE - USE - Step 8 USE - Step 8]()
Note:
For cavities deeper than 1.8 mm, use a layering technique.
- FINISHING
Finish under water spray using superfine diamond bur, silicone point and polishing strips (Fig. 9).
![GC CORPORATION - Fuji II LC CAPSULE - USE - Step 9 USE - Step 9]()
Note:
Apply a final coat of GC Fuji VARNISH (blow dry) or GC Fuji COAT LC (light cure for 10 sec.) or G-COAT PLUS (light cure for 20 sec.)(Fig. 10).
![GC CORPORATION - Fuji II LC CAPSULE - USE - Step 10 USE - Step 10]()
STORAGE
Store in a cool and dark place (4-25°C / 39.2-77.0°F). (Shelf life: 2 years from date of manufacture)
SHADE
A1, A2, A3, A3.5, A4, B2, B3, B4, C2 and C4 (10 shades based on Vita® shades).
Vita® is a registered trademark of Vita Zahnfabrik, Bad Säckingen, Germany.
PACKAGES
- Single shade package: 48 capsules.
- Dark Shade Assortment package: 24 capsules.
5 pcs each of A3.5, A4, B3 and B4; 4 pcs each of C4. - Light Shade Assortment package: 24 capsules.
5 pcs each of A1, A2, A3 and B2; 4 pcs each of C2.
*Average contents per capsule: 0.33g powder and 0.10g (0.085mL) liquid.
*Minimum net volume of mixed cement per capsule: 0.10mL.
Option: GC Capsule Applier (1 piece).
![]()
- In case of contact with oral tissue or skin, remove immediately with a sponge or cotton soaked in alcohol. Flush with water.
- In case of contact with eyes, flush immediately with water and seek medical attention.
MANUFACTURED BY
GC CORPORATION
76-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8585, Japan
DISTRIBUTED BY
GC AMERICA INC.
3737 West 127th Street, Alsip, IL 60803 U.S.A. TEL: +1-708-597-0900 PRINTED IN THE U.S.A.
![]()
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Need help?
Do you have a question about the Fuji II LC CAPSULE and is the answer not in the manual?
Questions and answers