Orbita 2043MD - Safe Box Operation Manual

Orbita 2043MD - Safe Box Operation Manual

Also See for 2043MD:

Advertisement

Orbita 2043MD - Safe Box Operation Manual

Opening safe box

2043MD safe can be opened by user password (4-6 digits, factory setting 1234) and master password (6 digits).

Steps for first time opening the safe box:

  1. Input 4*5# battery into outer connecting battery case, and connect battery case with safe box.
  2. Enter the factory setting user password "1234", then press"#", Nixie tube shows "", then you can pull the safe door.
  3. After door is opened, take out the battery and input into the safe inside battery case. (on the door backside)

Steps for using master password to open safe box:
Enter "**002#", input master password (refer to 3rd menu how to add mater password), press "#" to confirm to open the safe box.

Closing safe box

Method a. Enter 4-6 digits, press "#" to confirm, user password is set successfully. Close the safe door, user password will display on the Nixie tube. Guest can close the safe box by press "#" only within 15 minutes after setting the user password.

Method b. Enter "**002#", input 6 digits' master password, press "#" to confirm, Nixie tube shows "".

Method c. Use mechanical key to close the safe box

Anti - prying virtual password function

Under opening status, enter "**001#", show"", enter last master password, press"#" to confirm. If failed, Nixie tube shows"", if succeed, shows "", then can enter 6 digits' new master password. When shows "", enter same new password again, then finish setting. If set successfully, shows "", set wrongly. shows "". For new safe, no master password was set, then input new master password directly.

Use mechanical key to open the safe box when forgot password.

Notes

  1. When voltage is lower than "4.8"V, Nixie Tube will show " " and beep once, then need to change new battery.
  2. Enter wrong password will show "", if wrongly input 3 times, safe will be locked for 15 minutes, shows" +Minutes "
  3. Enter "**003#", can hide the password and shows "", do same operation again, will show the password.
  4. Click "*" to delete when enter passwords
  5. When safe is under opening status, enter "**0752456789#" to delete the parameters set by guests. Nixie tube will show " "
  6. When close the safe, if not close completely, nixie tube will show " " and can hear a long beep.
  7. Enter"**004#" to know the safe version. format is " +3 numbers "

www.orbitalock.com
www.orbitatech.com

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Orbita 2043MD - Safe Box Operation Manual

Advertisement

Need Assistance?

Do you have a question about the 2043MD that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents