Page 4
MODEL RL1 Series FWE-8K-1P-LV FWE - Freedom Won Encore 8K - Size 1P - One Phase LV - Low Voltage FWE-3K-1P-LV and FWE-8K-1P-LV and FWE-12K-3P-HV and FWE-5K-1P-LV FWE-10K-1P-LV FWE-15K-3P-HV...
Page 5
CONNECTION PORT Object Description Battery +/Battery - PV1+/PV1- PV2+/PV2- DC switch WiFi port for external WiFi Reserved port DRM/BMS USB port for upgrading Pressure valve EPS output FWE-3K-1P-LV and FWE-5K-1P-LV Grid output...
Page 6
DIAGRAM WIRING FWE-3K-1P-LV and FWE-5K-1P-LV Hybrid Inverter...
Page 7
CONNECTION PORT FWE-8K-1P-LV and FWE-10K-1P-LV...
Page 8
DIAGRAM WIRING FWE-8K-1P-LV and FWE-10K-1P-LV Hybrid Inverter...
Page 10
OPERATION STEP STEP 1: Following the diagram wiring and check the wiring connection is correct or not. Note that the CT crosses the L line, and the Arrow direction must forward to the grid, the terminal of RJ45 is connected to CT port on the inverter. STEP 2: After power on the inverter, Select "Language"...
Page 11
QUICK SETUP GUIDE Select 1 setting ESC key Input password LCD interface user The default password is 00000. Press up / down to adjust Select the Press enter Select the grid Press enter restart corresponding standards grid standard First, set the corresponding grid standard...
Page 12
QUICK SETUP GUIDE Set corresponding Input password Press enter 2: Battery Setup parameters of parameters Press enter battery Next, Set battery parameters...
Page 13
QUICK SETUP GUIDE Input password Press enter 1: System 1: Working set up settings mode Press enter Press enter Peak-shifting; Press enter Restart Self-use; Battery priority; Finally, set the system operation mode...
Page 15
WORKING MODE - SELF-CONSUME PV panel Encore Range Inverter Energy priority: load>battery>grid *Battery power only from PV Energy Grid Battery Load Power flow : Priority to load Supply power to Enough power to PV and Battery supply No PV and low capacity of Load and charge Feedback to the grid Power to the load at...
Page 16
WORKING MODE - BATTERY PRIORITY PV panel Encore Range Inverter Energy priority: battery>load>grid Grid Battery Load Power flow : Priority to battery Supply power to Enough power to When no PV , Grid will When No grid , the battery will Load and charge Feedback to the grid Offer the power to the...
Page 17
WORKING MODE - PEAK SHIFTING PV panel Encore Range inverter E n e r g y p r i o r i t y : b a t t e r y > l o a d > g r i d ( w h i l e c h a r g i n g ) L o a d >...
Page 24
QUESTION & ANSWER Q . H o w t o c h e c k t h e C T c o n n e c t i o n i s c o r r e c t o r n o t ?
Page 25
QUESTION & ANSWER Q . W h i c h p o r t i s c o n n e c t e d t o B M S c o m m u n i c a t i o n ? FWE-3K-1P-LV and FWE-8K-1P-LV and FWE-5K-1P-LV...