Download Print this page
Freedom Won RL1 Series Manual

Freedom Won RL1 Series Manual

Residental single phase hybrid inverter

Advertisement

Quick Links

Advertisement

loading
Need help?

Need help?

Do you have a question about the RL1 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Freedom Won RL1 Series

  • Page 2 CONTENT Product Introduction Operation Step III. Working mode Parameter meaning Notes...
  • Page 3 1. PRODUCT INTRODUCTION...
  • Page 4 MODEL RL1 Series FWE-8K-1P-LV FWE - Freedom Won Encore 8K - Size 1P - One Phase LV - Low Voltage FWE-3K-1P-LV and FWE-8K-1P-LV and FWE-12K-3P-HV and FWE-5K-1P-LV FWE-10K-1P-LV FWE-15K-3P-HV...
  • Page 5 CONNECTION PORT Object Description Battery +/Battery - PV1+/PV1- PV2+/PV2- DC switch WiFi port for external WiFi Reserved port DRM/BMS USB port for upgrading Pressure valve EPS output FWE-3K-1P-LV and FWE-5K-1P-LV Grid output...
  • Page 6 DIAGRAM WIRING FWE-3K-1P-LV and FWE-5K-1P-LV Hybrid Inverter...
  • Page 7 CONNECTION PORT FWE-8K-1P-LV and FWE-10K-1P-LV...
  • Page 8 DIAGRAM WIRING FWE-8K-1P-LV and FWE-10K-1P-LV Hybrid Inverter...
  • Page 9 2. OPERATION STEP...
  • Page 10 OPERATION STEP STEP 1: Following the diagram wiring and check the wiring connection is correct or not. Note that the CT crosses the L line, and the Arrow direction must forward to the grid, the terminal of RJ45 is connected to CT port on the inverter. STEP 2: After power on the inverter, Select "Language"...
  • Page 11 QUICK SETUP GUIDE Select 1 setting ESC key Input password LCD interface user The default password is 00000. Press up / down to adjust Select the Press enter Select the grid Press enter restart corresponding standards grid standard First, set the corresponding grid standard...
  • Page 12 QUICK SETUP GUIDE Set corresponding Input password Press enter 2: Battery Setup parameters of parameters Press enter battery Next, Set battery parameters...
  • Page 13 QUICK SETUP GUIDE Input password Press enter 1: System 1: Working set up settings mode Press enter Press enter Peak-shifting; Press enter Restart Self-use; Battery priority; Finally, set the system operation mode...
  • Page 14 3. WORKING MODE...
  • Page 15 WORKING MODE - SELF-CONSUME PV panel Encore Range Inverter Energy priority: load>battery>grid *Battery power only from PV Energy Grid Battery Load Power flow : Priority to load Supply power to Enough power to PV and Battery supply No PV and low capacity of Load and charge Feedback to the grid Power to the load at...
  • Page 16 WORKING MODE - BATTERY PRIORITY PV panel Encore Range Inverter Energy priority: battery>load>grid Grid Battery Load Power flow : Priority to battery Supply power to Enough power to When no PV , Grid will When No grid , the battery will Load and charge Feedback to the grid Offer the power to the...
  • Page 17 WORKING MODE - PEAK SHIFTING PV panel Encore Range inverter E n e r g y p r i o r i t y : b a t t e r y > l o a d > g r i d ( w h i l e c h a r g i n g ) L o a d >...
  • Page 18 4. PARAMETER MEANING...
  • Page 19 SYSTEM SETTING...
  • Page 20 BATTERY SETTING...
  • Page 21 GRID SETTING...
  • Page 22 PARALLEL SETTING...
  • Page 24 QUESTION & ANSWER Q . H o w t o c h e c k t h e C T c o n n e c t i o n i s c o r r e c t o r n o t ?
  • Page 25 QUESTION & ANSWER Q . W h i c h p o r t i s c o n n e c t e d t o B M S c o m m u n i c a t i o n ? FWE-3K-1P-LV and FWE-8K-1P-LV and FWE-5K-1P-LV...