Summary of Contents for Priva NUTRIJET

  • Page 1 Manual > NUTRIJET - USER...
  • Page 2 Priva owns the patents, patent applications, trademarks or other intellectual property rights regarding the products described in this publication. With this publication Priva does not grant the use of the aforementioned intellectual property rights. Product and company names this publication may not be used without the permission of Priva.
  • Page 3: Table Of Contents

    Location and environmental conditions ..................20 Operating software ........................... 21 Process phases ........................... 22 Turning the unit on and off ....................... 22 Power supply failure .......................... 23 Topping-up fertilisers and acid or lye ....................23 NutriJet - user - 00.002...
  • Page 4 ................... 47 Technical specifications - pumps ....................51 Technical specifications - inline dirt filter ..................51 Spare parts ............................52 NutriJet ............................52 Nutri-Line ............................54 Dosing channels ..........................55 Terms and abbreviations ........................62 NutriJet - user - 00.002...
  • Page 5: Aim And Scope

    The warranty expires if the product is not installed, used and maintained in accordance with the instructions in the Priva manual. For more details refer to the general terms of delivery (Priva will supply these on request and refer to www.priva.com) and the specifically agreed terms of delivery.
  • Page 6: Safety

    Safety - general • Only Priva approved installers/service engineers who have received product-specific training from Priva are allowed to install, configure, repair and, if necessary, alter the product. • Making alterations to the safeguards and safety icons on the equipment is prohibited.
  • Page 7: Meanings Of Safety Icons

    Wear ear protection and safety glasses Wear non-permeable gloves that are resistant to chemical substances Wear clean work clothes that cover as much of the skin as possible Wear (safety) boots Read the device manual NutriJet - user - 00.002...
  • Page 8: Safety Icons On The Unit

    • the protective measures required; • action to be taken in the event of contact with the skin or eyes or after inhalation or ingestion; • action to be taken in the event of leaks. NutriJet - user - 00.002...
  • Page 9: Electrical Safety

    The unit is powered from the mains voltage. There is a potential hazard of electrocution or fire resulting from a short circuit. You must therefore adhere to the following safety instructions: • Keep the housings of electrical components closed. • Keep the electrical parts dry. NutriJet - user - 00.002...
  • Page 10: Safety With Mechanical Parts

    The fan of the electric motor on the system pump is protected by a cover. • The motor protection switches the system pump off if it is consuming too much current due to overloading. The process computer detects this situation and then shuts down the entire unit. NutriJet - user - 00.002...
  • Page 11: Residual Risks

    Because the unit is usually connected to other external electrical equipment the unit has not been fitted with an emergency stop. The installer must install a separate emergency button near the unit which can be used to switch off the entire installation. NutriJet - user - 00.002...
  • Page 12: Product Description

    The pressure and capacity of the irrigation water supplied by the unit are dependent on the pump on the unit. Optionally, you can choose to regulate the pressure of the irrigation water with a frequency controller. NutriJet - user - 00.002...
  • Page 13: Structure

    NutriJet. The basic variants (without post-filtration, without pre-mixing) of the NutriJet Inline are in row 1, the other variants of the NutriJet Inline are in rows 2 and 3. The NutriJet Bypass is in row 4. NutriJet variants in main groups Max.
  • Page 14 Priva NutriJet 100/300/600 Inline NutriJet 100/300 Inline, with post-filtration and/or pre-mixing NutriJet 600 Inline, 1 mixing chamber, with post-filtration and/or pre-mixing NutriJet 600 Inline, 2 mixing chambers, with post-filtration and/or pre-mixing NutriJet - user - 00.002...
  • Page 15 Product description NutriJet 300/600 Bypass NutriJet - user - 00.002...
  • Page 16: Structure - Electrical Part

    Automatic: the pump is controlled by the process computer Main switch: The main disconnect switch has the following positions: • Off: no electrical power is being supplied to the unit • On: electrical power is being supplied to the unit NutriJet - user - 00.002...
  • Page 17 Mains: required mains voltage in VAC • Frequency: required mains frequency in Hz • Power: nominal power consumption in kW of system pump • Name and address of the manufacturer (Priva B.V.) • Manual icon • CE mark NutriJet - user - 00.002...
  • Page 18: Operating Principle

    • NutriJet Bypass: the unit is installed next to the main line. Part of the water is guided out of the main line, via the unit, back to the main line. The unit delivers such a high dosage that the correct dosage is achieved after mixing in the main line.
  • Page 19 The rinse water is discharged via the drain line (42). If not already present on the unit, a non-return valve (43) must be installed behind the filter. If non-return valve (43) is present on the unit, non-return valve (13) is not required. NutriJet - user - 00.002...
  • Page 20: Nutrijet Bypass

    (4) and the outlet line (14) must be equipped with a manually operated valve (5). The operation of other components of the NutriJet Bypass and those of the NutriJet Inline are the same. A frequency controller, EC pre-control or post-filtration cannot be used with the NutriJet Bypass.
  • Page 21: Transport And Storage

    Transport and storage Transport and storage Only Priva approved installers/service engineers who have received product-specific training from Priva are allowed to transport and store the unit. The work to be performed by the installer for transport and storage is described in the unit’s installer manual.
  • Page 22: Operation

    (such as the EC sensor connections). Moreover, the less cold the supply water is the more accurately the unit will dose and mix. • Chemical pretreatment by acidification of the supply water (Priva Neutralizer) if the water contains too much bicarbonate (see Supply water quality (page 40)).
  • Page 23: Operating Software

    1000 m above sea level (Cavitation may occur in the system pump when the ambient pressure is too low.) Pollution factor (NEN-EN-IEC maximum 2 (normal, non-conducting pollution) 61010-1) Operating software Refer to the relevant process computer software manual. NutriJet - user - 00.002...
  • Page 24: Process Phases

    The running program can be interrupted via the operating software (see Setting the unit to maintenance mode (page 26)). NutriJet - user - 00.002...
  • Page 25: Power Supply Failure

    Operation is described in the software manual for the relevant process computer (Connext or Compass) and depends on the software version used. See chapter Procedures > Operating the dosing unit. Make (or arrange to be made) a back-up of all settings before adjusting them. NutriJet - user - 00.002...
  • Page 26 If you use supply water with an EC value that is too high it is possible that no fertilisers or a very small quantity of fertilisers will be dosed. NutriJet - user - 00.002...
  • Page 27: Maintenance And Repair

    • Some maintenance activities may only be performed by authorised Priva installers/service engineers who have received product-specific training from Priva. This is indicated in the preventative maintenance schedule. • Switch the unit off using the main disconnect switch before carrying out any maintenance work.
  • Page 28: Setting The Unit To Maintenance Mode

    • Do not press too hard on the operating panel / display and the keyboard (if fitted) when removing dirt. Put the unit back into operation. NutriJet - user - 00.002...
  • Page 29: Cleaning The Inline Dirt Filter

    Rinse the filter element underneath the tap until clean. Replace the filter element and tighten the filter element. Put the unit back into operation. Cleaning the dirt filter of the dosing channel Dirt filter of dosing channel NutriJet - user - 00.002...
  • Page 30: Cleaning The Ph Sensors

    Rinse the glass membrane well with distilled water. Then immerse the sensor for at least 30 minutes in a 50/50 mixture of pH 4 buffer and 4M KCl before using it again. It is advisable to recalibrate the pH measurement after cleaning. Cleaning the pH sensor thoroughly NutriJet - user - 00.002...
  • Page 31 Priva are supplied separately and still need to be connected to the unit. To do this, perform the following steps. If you use pH sensors that were not ordered from Priva, these pH sensors must comply with the same specifications as the Priva pH sensors. See Technische specificaties - pH-sensor.
  • Page 32: Cleaning The Flow Sensor

    Screw the flow sensor back onto the T-piece: you can only do this one way. Fill and bleed the main irrigation line to prevent water hammer. Check that the flow sensor coupling is not leaking. NutriJet - user - 00.002...
  • Page 33: Troubleshooting

    During the production of irrigation water, the pressure on the line to the venturis is too low (page 33) NutriJet Bypass: The suction pressure on the line after the mixing chamber is too low or too high (page 33) A fertiliser, acid or lye is not being dosed (page 33) The desired EC value is not being achieved (page 34) The EC value swings wildly and ‘overshoots’...
  • Page 34 NutriJet Bypass: EC control is unstable (page 32) NutriJet Bypass: The pressure on the pressure reducing valves in the incoming line is too The first manometer on the pressure reducing valves in the incoming line indicates too low a pressure.
  • Page 35 Clean the dirt filter (see Cleaning the inline dirt filter (page 27)). NutriJet Bypass: The suction pressure on the line after the mixing chamber is too low or too high Possible cause Solution The pressure reducing valve or valves in the bypass line Priva Partner: adjust the pressure reducing valve or have not been adjusted correctly.
  • Page 36 • Increase the concentration of the acid or lye. The supply water contains too much bicarbonate. Priva Partner: install a pre-treatment system for the supply water. The nutrient recipe has been set incorrectly. Adjust the quantity of acid or lye in the nutrient recipe, taking into account the quantity of bicarbonate in the supply water.
  • Page 37 Reduce the quantity of acid or lye in the recipe. The supply water contains too little bicarbonate. Priva Partner: install a flow rate ratio control to mix the supply water with another water source that contains the correct amount of bicarbonate.
  • Page 38: Troubleshooting - Process Computer

    Some irrigation valves no longer open Possible cause Solution A fuse of the relevant fuse group on the I/O board has Priva Partner: replace the defective fuse (see Zekeringen burned out. vervangen). The measured fertiliser concentrations do not match the recipe...
  • Page 39: Taking Out Of Operation

    Taking out of operation Taking out of operation Only authorised Priva installers/service engineers who have received product-specific training from Priva may take the unit out of operation. The work to be performed by the installer for taking the unit out of operation is described in the unit’s installer manual.
  • Page 40: Appendices

    Priva Appendices NutriJet - user - 00.002...
  • Page 41: Ec Declaration Of Conformity

    - Part 1: General requirements NEN-EN-IEC 62368-1 Audio/video, information and communication technology equipment - Part 1: Safety requirements The technical file was compiled by the R&D department of Priva B.V. The Netherlands, De Lier, February 2012 M. Prins Managing Director...
  • Page 42: Supply Water Quality

    When using reverse osmosis water, but in some cases rain water also, too low a quantity of HCO (< 0.10 mmol/l) may be deemed to exist in the supply water. Dosing acid may give rise to an unstable chemical reaction in the irrigation water. NutriJet - user - 00.002...
  • Page 43 Dosing acid may then result in there being insufficient time to neutralise the bicarbonate. Stabilisation is possible by pre-treating the supply water using a Priva Neutralizer with an acid injection and aeration system. The treated supply water is then stored in a stock tank.
  • Page 44: Preparing An Acid Supply

    To dilute this to 3% (weight percent), it is necessary to mix the contents of the barrel with 315, 470 or 640 l fresh water. Always pour the acid into the water instead of the water into the acid, and always stir the mixture thoroughly to homogenise it. Example NutriJet - user - 00.002...
  • Page 45 With a 20 litre barrel of 68% nitric acid (28.2 kg), 640 litres of 3% nitric acid can be made by first pouring 310 litres of fresh water into a barrel containing sufficient volume, then the 20 litres of nitric acid and then the remaining 310 litres of water. NutriJet - user - 00.002...
  • Page 46: Technical Specifications - Product Options

    • 1 manometer for suction side of system pump • 1 manometer for outgoing unit pressure (discharge side of system pump) Regulations and standards with See the EC Declaration of Conformity. which the unit complies NutriJet - user - 00.002...
  • Page 47: Technical Specifications - Process Computer

    The actual moment of starting (after the start program has been launched) can be influenced based on the drain quantity. Supply water from different sources can be mixed on the basis of EC or flow ratio NutriJet - user - 00.002...
  • Page 48 In the Connext software, valve groups are linked to start programs, in the Compass software valves are linked to start programs. To make use of these options, sensors and other components (such as I/O expansions) that are not supplied as standard may be required. NutriJet - user - 00.002...
  • Page 49: Technical Specifications - Mechanical

    Appendices Technical specifications - Mechanical Technical specifications - mechanical The illustrations and tables in this chapter show the dimensions of the NutriJet. Please read the explanation first: General explanation: • All dimensions in the tables are in millimetres unless specified otherwise.
  • Page 50 Priva NutriJet 100/300/600 Inline NutriJet 100/300/600 Inline NutriJet - user - 00.002...
  • Page 51 Appendices NutriJet 100/300 Inline, with post-filtration and/or pre-mixing NutriJet 100/300 Inline, with post-filtration and/or pre-mixing NutriJet - user - 00.002...
  • Page 52 Priva NutriJet 600 Inline, 1 mixing chamber, with post-filtration and/or pre-mixing NutriJet 600 Inline, 2 mixing chambers, with post-filtration and/or pre-mixing NutriJet 600 Inline, with post-filtration and/or pre-mixing NutriJet - user - 00.002...
  • Page 53: Technical Specifications - Pumps

    The technical specifications for the pump(s) may be found in the supplied pump manual. Technical specifications - inline dirt filter Article description Inline dirt filter and corresponding PVC coupling 32 mm Article number 630505 Housing Interior Mesh opening 1.4 mm NutriJet - user - 00.002...
  • Page 54: Spare Parts

    The following tables show the spare parts. • Only installers/service engineers approved by Priva who have received product-specific training from Priva are allowed to install, configure, repair and, if necessary, alter the product. • Only use original Priva spare parts.
  • Page 55 757551 757551 757555 Seal set for hydraulic piston (for use at least once every 3 757550 757550 757550 757556 years) Flushing valve 757558 757558 757558 757559 O-ring maintenance set 757709 Filter screen replacement kit 757710 NutriJet - user - 00.002...
  • Page 56: Nutri-Line

    Priva Nutri-Line Nutri-Line frequency controller Article description Article number Fan for Vacon 100 frequency controller 756085 756086 Display for Vacon 100 frequency controller 756087 756087 Nutri-Line Connext PCBAs NutriJet - user - 00.002...
  • Page 57: Dosing Channels

    3770933 (VP9533) I/O connection board for two pH sensors 3770972 PCBA (VP9572) External connection board module (VP9552) 3771262 Internal connection board module (VP9550) 3771256 Dosing channels Dosing channels - Fertiliser 100 l/h and 300 l/h NutriJet - user - 00.002...
  • Page 58 752137 752137 752137 752137 Venturi 752450 752450 752450 Seal hose nozzle - mixing 754357 754357 754357 754357 754357 754357 chamber/tank Seal manifold - venturi 754357 754357 754357 754357 754357 754357 Dosing channels Fertilisers 600 l/h NutriJet - user - 00.002...
  • Page 59 752137 752137 752137 752137 Venturi 752451 752451 Seal hose nozzle - mixing 754357 754357 754357 754357 chamber/tank Seal manifold - venturi 754357 754357 754357 754357 Dosing channels - low-concentration acids 100 l/h and 300 l/h NutriJet - user - 00.002...
  • Page 60 754581 754581 Seal dosing valve - venturi 754582 754582 754582 Venturi 752450 752450 752450 Seal hose nozzle - mixing 754357 754357 754357 chamber/tank Seal manifold - venturi 754357 754357 754357 Dosing channels fertilisers 1000 l/h NutriJet - user - 00.002...
  • Page 61 Non-return valve 750416 750416 Seal dosing valve - venturi 754357 754357 Venturi 755050 Seal nozzle hose - mixing 754357 754357 chamber/tank Seal venturi 751055 751055 Dosing channels - highly concentrated acid and lye 50 l/h NutriJet - user - 00.002...
  • Page 62 Seal hose nozzle - mixing 754357 754357 chamber/tank Seal manifold - venturi 754357 754357 Seal regulating valve - 750690 754598 venturi * Use EPDM seal foot valve kit Low volume dosing channel 2 l/h and 8 l/h NutriJet - user - 00.002...
  • Page 63 Dosing valve connector 750469 750469 Connection dosing valve - 754585 754585 venturi Seal dosing valve - venturi 754582 754582 Venturi 752452 752452 Seal hose nozzle - mixing 754357 754357 chamber/tank Seal manifold - venturi 754357 754357 NutriJet - user - 00.002...
  • Page 64: Terms And Abbreviations

    (e.g. after changing the recipe). Flushing takes place by opening the flush valve (usually controlled by the process computer) at the end of the main irrigation line and pumping the new irrigation water in the irrigation line. NutriJet - user - 00.002...
  • Page 65 Filling a sand filter with water in such a way that the bed of sand is even and the filter is ready for use. The dirt that has come from the bottom of the sand filter after the settlement is transported to the drain water tank. NutriJet - user - 00.002...
  • Page 66 Peak load (by increased pressure) of components of a water system, caused by a sudden standstill or strong direction change of the water flow (e.g. after the fast closure of a valve or after the starting of a pump). NutriJet - user - 00.002...
  • Page 67 Appendices NutriJet - user - 00.002...
  • Page 68 Priva (head office) Zijlweg 3 2678 LC De Lier The Netherlands See www.priva.com for contact information of a Priva office or partner for your region.