Installation Instructions
ASME
NY Thermal Inc.
Tel: (506) 657-6000
Toll Free: 1-800-688-2575
Fax: 1-506-432-1135
Web: www.nythermal.com
Email: info@nythermal.com
occupants or, death.

Applicable Boiler Models

Tx51-200
Tx151C
Tx200C

Kit Contents

85022 Heat Exchanger Assembly Tx51 OR
85023 Heat Exchanger Assembly Tx81 OR
85024/85760 Heat Exchanger Assembly Tx101 OR
85025/85761 Heat Exchanger Assembly Tx151, Tx151C
OR
85026 Heat exchanger Assembly Tx200, Tx200C
Installation Instructions

Tools Required

Needle Nose Pliers
Phillips #2 screwdriver
Flat Screwdriver
¼" nut driver or wrench
5/16" nut driver or wrench
10mm wrench
3/8" Wrench
Pipe wrench
Combustion Analyzer
Saw to remove venting
Adjustable wrench
Vacuum Cleaner

Disassembly Instructions

Turn off power and gas to the boiler.
Drain the boiler: use a wet/dry vacuum to help remove excess water.
Remove the exhaust venting.
85022 / 85023 / 85024 / 85025 / 85026/85760/85761
Tx151-200 Heat Exchanger Assembly, ASME
Post Serial # 72000
c/w Burner Door and Flue Box
This boiler must be service by a qualified heating technician. Failure to properly
maintain or service this appliance may result in property damage, serious injury to
The installation of this kit must be performed by a qualified boiler technician.
Installing this kit without the proper background and training is hazardous and may
result in property damage or death.
85022/85023/85024/85025/85026 Heat Exchanger
Heat Exchanger
Revision Date: 21-08-2014
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T 151-200 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for NTI T 151-200 Series

  • Page 1 Installation Instructions 85022/85023/85024/85025/85026 Heat Exchanger ASME Revision Date: 21-08-2014 NY Thermal Inc. 85022 / 85023 / 85024 / 85025 / 85026/85760/85761 Tel: (506) 657-6000 Tx151-200 Heat Exchanger Assembly, ASME Toll Free: 1-800-688-2575 Fax: 1-506-432-1135 Post Serial # 72000 Web: www.nythermal.com Email: info@nythermal.com c/w Burner Door and Flue Box This boiler must be service by a qualified heating technician.
  • Page 2 Installation Instructions 85022/85023/85024/85025/85026 Heat Exchanger ASME Revision Date: 21-08-2014 Remove the gas line from the gas valve. Remove the vinyl hose from the gas valve. Remove the air intake from the gas valve Venturi by loosening the MJ coupling. MJ Coupling Disconnect the flame probe and ignition electrode cables.
  • Page 3 Installation Instructions 85022/85023/85024/85025/85026 Heat Exchanger ASME Revision Date: 21-08-2014 Remove the auto-air vent clip and lift the auto-air vent assembly up to remove it from the heat exchanger. Auto Air Vent O-Ring from Prior to installing the air vent in the new Shipping Plug heat exchanger remove the shipping plug and O-ring.
  • Page 4 Installation Instructions 85022/85023/85024/85025/85026 Heat Exchanger ASME Revision Date: 21-08-2014 Combi Models Tx151C and Tx200C: Remove the white plastic retaining clips from the copper pipes by rotating the clips counter-clockwise to unlock them. Remove the pipes from the combi block by pulling them away from the combi block.
  • Page 5 Installation Instructions 85022/85023/85024/85025/85026 Heat Exchanger ASME Revision Date: 21-08-2014 Remove the heat exchanger hold down brackets. Remove the heat exchanger, blower motor, and gas valve as an assembly. Transfer the blower motor and gas valve to the new heat exchanger prior to installing the new heat exchanger.

This manual is also suitable for:

T 151c seriesT 200c series85022850238502485025 ... Show all

Table of Contents