Download Print this page

babcockdavis ACOUSTIMAX BSVZ Installation, Operation And Maintenance Manual

Smoke vent

Advertisement

Quick Links

ACOUSTIMAX™ SMOKE VENT
Model(s): BSVZ/BSVY
GENERAL DESCRIPTION
Acoustical smoke vents are primarily used in theaters and performing arts centers because
they block the intrusion of exterior environmental noise. Acoustical smoke vents provide both
sound control and thermal performance. The SVZ has STC50/OITC 47 and ISO 140-18 Rainfall
36.7 dB sound ratings. The SVY has STC50/OITC 39 sound ratings.
The AcousticMAX sound rated series meets International Building Code IBC 1207 sound
transmission class requirements and is used in high end theater applications as well as in
building applications where condensation is a concern.
Sound transmission is tested by an independent lab accredited by the U.S. Department of
Commerce and the National Institute of Standards and Technology for conducting official
acoustical test procedures for sound transmission class (STC), Outdoor-Indoor Transmission
Class (OITC), and Sound Insulation of Building Elements (rainfall dB) according to the following
tests:
• ASTM E90 Laboratory Measurement of Airborne Sound Transmission of Building
Partitions
• ASTM E1332 Standard Classification for Determination of Outdoor-Indoor Transmission
Class
• ISO 140 Acoustics Laboratory Measurement of Sound Insulation of Building Elements
Great Products. Better Partners.
Direct Service Done Right
Babcock-Davis is a leader in roof hatches, smoke vents and safety railings for the commercial roofing market. We also manufacture architectural
Since 1948, Nystrom has been the go-to manufacturer of specialty building products providing a wide range of floor, roof, wall,
access and safety-related building products for commercial structures. Babcock-Davis provides local connections through a broad distribution
ceiling, and stair access products that create safer, more accessible buildings. We offer hassle-free services including access to
network to accelerate and simplify the building process for contractors and building owners, offering hassle-free services including access to
technical experts, REVIT tools for BIM, HPDs for LEED v4, 3-part specifications and AIA-accredited continuing education courses.
technical experts, REVIT tools for BIM, HPDs for LEED v4, 3-part specifications and AIA-accredited continuing education courses.
Installation, Operation
+ Maintenance Manual
Acoustical smoke vents are designed to open
automatically to provide emergency smoke and heat
ventilation. Prompt venting during fire emergencies is
essential for the safe evacuation of occupants and for
effective fire-fighting conditions within a building. The
smoke vent is not intended for use as general-purpose
building ventilation devices. International Building
Code (IBC) requires smoke venting in a variety of
applications including Section 410 for stages and
platforms, Section 910 for factory and storage
occupancies .
1
©2023 Babcock-Davis, Inc.
Rev 02/2023

Advertisement

loading

Summary of Contents for babcockdavis ACOUSTIMAX BSVZ

  • Page 1 Installation, Operation + Maintenance Manual ACOUSTIMAX™ SMOKE VENT Model(s): BSVZ/BSVY GENERAL DESCRIPTION Acoustical smoke vents are designed to open automatically to provide emergency smoke and heat ventilation. Prompt venting during fire emergencies is essential for the safe evacuation of occupants and for effective fire-fighting conditions within a building.
  • Page 2: Installation

    Installation & Operation + Maintenance AcousticMAX Smoke Vent Model(s): BSVZ/BSVY Introduction + Safety GENERAL SAFETY PRECAUTIONS Improper selection, installation, or use can cause personal injury or property damage. It is solely the responsibility of the user, through their own analysis, to select products suitable to the specific application requirements, ensure proper maintenance and use as intended.
  • Page 3: Operation

    Installation & Operation + Maintenance AcousticMAX Smoke Vent Model(s): BSVZ/BSVY 2. The smoke vent curb flange comes with two (2) types of mounting holes to accommodate the following fastening methods: a. Mark the predrilled 5/8” diameter holes from the mounting flange through to the roof deck or a concrete curb.
  • Page 4 Installation & Operation + Maintenance AcousticMAX Smoke Vent Model(s): BSVZ/BSVY 1. Smoke vents are designed to open thermally when a UL listed fusible link melts at temperatures of 165˚F, 212˚F, 280˚F, 350˚F, 360˚F, 370˚F, 386˚F or 450˚F. Fusible links are easily accessed from the roof for replacement, as detailed. 2.
  • Page 5: Maintenance

    Installation & Operation + Maintenance AcousticMAX Smoke Vent Model(s): BSVZ/BSVY Test for proper operation using one or more of the following methods. 1. Manual pull handles: Pull the manual pull handle from the exterior of the smoke vent. Pull the internal manual pull handle if it has been routed down to the floor level. 2.
  • Page 6 Installation & Operation + Maintenance AcousticMAX Smoke Vent Model(s): BSVZ/BSVY If there are any questions during the installation, operation, or maintenance of smoke vents, please call 800-547-2635 toll-free. OVERVIEW – MANUAL WINCH OPTION Smoke vents with manual winch remote operation provide the additional convenience of opening and closing the smoke vents from a remote location, such as the catwalk or floor level.
  • Page 7 Installation & Operation + Maintenance AcousticMAX Smoke Vent Model(s): BSVZ/BSVY Reset at Roof Level 1. Feed out a minimum of 14’ of cable at lower winch to create slack. 2. At upper winch, remove spent fusible link from the system by removing the retaining lock nuts.
  • Page 8 Installation & Operation + Maintenance AcousticMAX Smoke Vent Model(s): BSVZ/BSVY 3. Rig the 1/8” manual winch cable, 1/16” HOA cable, and 1/16” manual release cable down to the floor level winch. (All three cables should be coiled on the interior side of the unit) 4.
  • Page 9 Installation & Operation + Maintenance AcousticMAX Smoke Vent Model(s): BSVZ/BSVY OVERVIEW Smoke vents with linear actuators are designed to conveniently open and close smoke vents remotely with a push button controller. The system is comprised of linear actuators (one per cover), a control box mounted to the inside of the smoke vent curb, a 2 position (open, close) push button station.
  • Page 10 QUESTIONS? For more information on installation, repair, or replacement, please contact Customer & Sales Support at 800-547-2635 or visit babcockdavis.com Great Products. Better Partners. Direct Service Done Right Babcock-Davis is a leader in roof hatches, smoke vents and safety railings for the commercial roofing market. We also manufacture architectural ©2023 Babcock-Davis, Inc.

This manual is also suitable for:

Acoustimax bsvy