Replacing the injectors
Replace the nozzles using the appropriate wrench
and tighten them carefully to guarantee the seal.
Ensure that the nozzle does not become detached
during removal or fastening.
Replacing the outer flame nozzle on the multi-crown
burner
Requirement: The upper part of the appliance has
been removed.
→ "Removing the upper part of the appliance (glass
plate with cut-out profiles)", Page 10
1.
To gain access to the main nozzle, loosen the
fastening screw
​ ⁠ and pull the sleeve
2.
Remove the nozzle by turning it anti-clockwise
and screw in the new outer flame nozzle
3.
Set the spacing of the adjustment sleeve for the air
supply to dimension Z, as shown in the table.
→ "Injectors", Page 10
4.
Tighten the fastening screw.
​ ⁠ back.
Replacing the inner flame nozzle on the multi-crown
burner
Requirement: The upper part of the appliance has
been removed.
→ "Removing the upper part of the appliance (glass
plate with cut-out profiles)", Page 10
1.
Unscrew the tube by applying pressure to the
sleeve in the opposite direction to hold it in place
and pulling the tube out of the sleeve
​ ⁠
​ ⁠
​ ⁠ .
Installation instructions en
​ ⁠ .
​ ⁠
11