Download Print this page

Warner Instruments FireRight LT Instruction Sheet

Advertisement

Quick Links

OPERATION
FireRight LT
To operate the
manually, proceed as follows:
1.
Turn the kiln on.
Notice either the HEAT or LIMIT light glows, indicating that the system
2.
is on.
When operating manually, the controller has two modes; soak or shut-
3.
off. To select the soak mode, depress the pushbutton switch, leaving it
latched in the "pressed' position. Push the button a second time to release
the latch, leaving the control in the shut-off mode.
To reset the controller when latched off in the shut-off mode, depress the
4.
pushbutton, then press it again to release the latch.
5.
Adjust the set point knob to the desired soak or shut-off temperature.
6.
In the soak mode, the controller will maintain the kiln's temperature at the
level you have set. In the shut-off mode, the controller will permit the
kiln's temperature to rise to the limit you have set, then shut it off,
allowing it to cool at its own natural rate.
SERVICE
If you have questions, please give the dealer or kiln manufacturer from whom you
purchased your controller the first opportunity to assist you.
FireRight LT
warrants
units for one-year. We will repair or replace, without charge,
units that fail because of defective material or workmanship. Factory service is available
a reasonable flat rates for all other cases, and can be handled through your dealer, or
factory-direct.
FireRight
©
/Warner Instruments 1996-2009
FireRight
Controls
Warner Instruments
1320 Fulton Street PO Box 604
Grand Haven MI 49417 USA
Phone: (616) 843-5342
Internet:
http://www.fireright.com
INSTRUCTION SHEET
FireRight LT
Temperature Controller
for Ceramic Kilns
GENERAL INFORMATION
FireRight LT
The
Controller is a simple non-indicating temperature controller specially
designed for use with ceramic kilns. Soak and Shut-Off operation is provided for, over a
temperature range of 0 to 2500°F. The controller is provided on a single panel, suitable
for flush mounting on most kiln switch boxes.
FireRight LT
The
can be used to supply power for small kilns, and to operate high
voltage power switching devices on larger kilns, such as definite purpose contactors and
mercury relays. Standard push-on connectors permit wiring for either 110vac or 220vac,
50/60Hz power. A single-pole electrical contact, capable switching up to 15 amps at
240vac, constitutes the controller's output. Since all but the smallest kilns draw more
than 15 amps, a power relay or definite purpose contactor is normally also required to
complete the installation.

Advertisement

loading

Summary of Contents for Warner Instruments FireRight LT

  • Page 1 OPERATION INSTRUCTION SHEET FireRight LT FireRight LT To operate the manually, proceed as follows: Turn the kiln on. Notice either the HEAT or LIMIT light glows, indicating that the system is on. Temperature Controller When operating manually, the controller has two modes; soak or shut- for Ceramic Kilns off.
  • Page 2 INSTALLATION FireRight LT kiln temperature controller may be installed on the kiln, or in a remote enclosure. If installed on the kiln, the temperature at the mounting location must not exceed 130°F during operation. The control can be mounted in panels as follows: Provide a rectangular cutout measuring 4 ”...