Electrical Connections
Be sure to check the data plate, located on the liner of the cabinet, for required voltage prior to connecting the unit to a power
source. The specifications on the data plate supersede any future discussion.
The standard unit is equipped with an 8 foot power cord that requires a 115 Volt, 60 Cycle, 1 Phase properly grounded electrical
receptacle. The power cord comes with a 3 prong plug for grounding purposes. Any attempt to cut off the grounding spike or to
connect to an ungrounded adapter plug will void the warranty, terminate the manufacturers responsibility and could result in serious
injury.
The circuit must be protected with a minimum 15 ampere fuse or breaker. The unit must be isolated on a circuit and not plugged
into an extension cord.

OPERATION

Initial Start Up
After satisfying the installation requirements, the unit is ready to start. The unit will start when the power cord is connected to the
required power source. Allow the unit to run a minimum of two hours before loading it with product. When loading the unit with
product, take care not to block the air flow to the fans at the top of the cabinet as this would affect the performance of the cabinet.
Electronic Temperature Control
The Electronic Temperature Control is located on the front of the cabinet above the door. It is set at the factory to a temperature of
0° F. To obtain colder temperatures, remove the Outer Evaporator Cover, push the set key and then push the down arrow on the
Electronic Temperature Control. To obtain warmer temperatures, push the set key and then push the up arrow on the Electronic
Temperature Control. Allow the unit a minimum of one hour to respond to a control setting adjustment.
Defrost
Your Silver King unit is an automatic defrost unit. No additional plumbing is required. Automatic defrosting is accomplished by a
defrost heater controlled by the Electronic Temperature Control. Frost buildup on the evaporator coil is cleared at six hour intervals.
Defrost water is collected in a pan located in the compressor compartment where it is evaporated into the room air. It is important
that the unit be level so the condensate can drain properly.

MAINTENANCE

Preventative maintenance is minimal although these few steps are very important to continued operation and maximizing the life of
the appliance.
Cabinet Surfaces
The cabinet interior and exterior are stainless steel. These surfaces should be cleaned periodically with a solution of warm water
and mild soap. After cleaning the surfaces should be rinsed with clean water and wiped dry with a soft cloth. Stainless steel
cleaners can also be used. Should a surface become stained, do not attempt to clean with an abrasive cleaner or scouring pad.
Use a soft cleanser and rub with the grain of the metal to avoid scratching the surface. Always rinse well and dry after cleaning.
Do not use chlorinated cleaners.
Condenser
Periodically, dust on the Filter Screen must be cleaned. The Filter Screen is located on the top of the cabinet. To clean it simply
pull it out the front of the unit and rinse it in a stream of water. Dry the screen by tapping it on a counter or floor. Replace the Filter
Screen by placing it into the filter screen tracks on the top of the unit and sliding all the way to the rear of the cabinet. This will need
to be done regularly to maintain the compressor warranty.
The Condenser itself should also be cleaned periodically. See the cleaning instructions located on the Rear Panel.
MODEL
SERIAL NO.
DATE INSTALLED