Installation; Electrical Connections - Silver King SKCTMDI Technical Manual And Replacement Parts List

Counter top drop-in merchandiser
Hide thumbs Also See for SKCTMDI:
Table of Contents

Advertisement

Available languages

Available languages

Thank you for purchasing Silver King food service equipment. Our goal is to provide our customers with the most reliable
equipment in the industry today. Please read this manual and the accompanying warranty information before operating your new
Silver King unit. Be sure to complete and mail the warranty card within 10 days of purchase to validate your warranty.
INSPECT FOR DAMAGE AND UNCRATE
Upon delivery of your new Silver King unit, uncrate at once to inspect for possible damage following the instructions printed on the
exterior of the container. Report any damages to the carrier responsible for transportation and promptly present a claim for any
evidence of mishandling. Save all packaging materials if a claim is to be filed.

INSTALLATION

If your Silver King unit has a stainless steel exterior it has been protected by a plastic covering during manufacturing and shipping.
This covering can be readily stripped before installation. After removing this covering, wash the interior and exterior surfaces using
a warm, mild soapy water solution and a sponge or cloth.
Lid
For shipping purposes the Lid Assembly has been taped to the cabinet. Remove all the tape from the Lid Assembly and install the
Lid Assembly on the cabinet by holding in the hinge pins at the back of the Lid Assembly and inserting them into the holes in the
Hinge Brackets on the cabinet.
LOCATION
When locating your countertop drop-in display merchandiser, convenience and accessibility are important considerations, but the
following installation guidelines must be followed;
When installed in a countertop, provisions need to be in place for the unit to receive proper ventilation for the compressor. The
drawing on the opposite page shows minimum ventilation requirements for the unit. Do not install the unit in cabinetry that does
not have provisions for ventilation as that would void all warranties.
Always avoid placing the unit next to an oven, heating element or hot air source that would affect the operation of the unit.
The unit must be level.
The counter must be able to support a minimum of 150 pounds.

Electrical Connections

Be sure to check the data plate, located on the liner of the cabinet, for required voltage prior to connecting the unit to power. The
specifications on the data plate supersede any future discussion. The standard counter-top drop-in display merchandiser is
equipped with an eight (8) foot power cord that requires a 115 Volt, 60 Cycle, 1 phase properly grounded electrical receptacle. The
power cord comes with a 3 prong plug for grounding purposes. Any attempt to cut off the grounding spike or to connect to an
ungrounded adapter plug will void the warranty, terminate the manufacturers responsibility and could result in serious injury.
The electrical circuit must be protected with a 15 or 20 ampere fuse or breaker. The unit must be isolated on a circuit and not
plugged into an extension cord.