  • Page 1 GAGE APPLIED TECHNOLOGIES CS1220 Hardware Manual Reorder #: MKT-HWM-PCI01-CS1220 0408...
  • Page 2 Applied Technologies, Inc. may make improvements and/or changes in the products and/or programs described in this publication at any time. The latest copy of this manual can be found on our web page at www.gage-applied.com in the Downloads section, User Manuals.
  • Page 3: Table Of Contents

    Table of Contents What you should receive with your CompuScope 1220 ..................4 CompuScope 1220 compliance statement ......................7 CompuScope 1220 product introduction ........................8 CompuScope 1220 specifications...........................9 CompuScope 1220 ordering information ......................13 CompuScope 1220 simplified block diagram.......................14 CompuScope 1220 connectors and headers......................15 CompuScope 1220 throughput &...
  • Page 4: What You Should Receive With Your Compuscope 1220

    If you order an independent CompuScope 1220 card, you should receive the following articles: • CompuScope 1220 card. You should notice the configuration of the BNC connectors on the face plate of your CompuScope 1220 card. If you purchased a CompuScope 1220-4M or CompuScope 1220-8M card, you should see a piggyback memory board attached to the back of the card, as shown below.
  • Page 5 Hardware manual, including Driver Installation Guide Note that you will receive only one copy of the Hardware Manual per order placed with Gage. Additional copies can be requested at order time. The Hardware Manual is also available in PDF format on the Gage Software Disk or you can download card-specific manuals from Gage’s...
  • Page 6 • If you ordered Master or Slave upgrades with your CompuScope 1220 cards, you will receive one of the following Master/Slave Timing Modules (actual Master/Slave Timing Module may not be exactly as shown). 2 Slot Master/Slave Timing Module 2-Slot Master/Slave Timing Module is used for:...
  • Page 7: Compuscope 1220 Compliance Statement

    CompuScope 1220 compliance statement Category Standards or description EC Declaration of Meets intent of Directive 89/336/EEC for Electromagnetic Compatibility. Conformity – EMC Compliance was demonstrated to the following specifications as listed in the Official Journal of the European Communities: EN 61326...
  • Page 8: Compuscope 1220 Product Introduction

    • Bus Mastering CompuScope 1220 cards are fully capable of becoming a bus master in order to transfer data at the maximum rate of 50 MB/s. A bus Master is a card that can take control of the bus and transfer data to any PCI target device such as system RAM without any involvement from the CPU.
  • Page 9: Compuscope 1220 Specifications

    CompuScope 1220 specifications PLEASE CHECK THE GAGE WEBSITE FOR THE MOST UP-TO-DATE SPECIFICATIONS. SYSTEM REQUIREMENT PCI-based computer with at least one free full-length PCI slot, 128 MB RAM, 50 MB hard disk and SVGA video. SIZE Plugs into one full-length PCI slot, 13” x 4.1”.
  • Page 10 Level Accuracy: ± 10% of full scale Slope: Positive or Negative, software selectable Post Trigger Data: 64 points minimum in single record acquisition 128 points minimum in multiple record acquisition Can be defined with a 64 point resolution CompuScope 1220...
  • Page 11 Number of Trigger Inputs: 2 per card Trigger Source: CH A, CH B, EXT or Software (Master card only) Input combination: Wired-OR Sensitivity: ± 20% of full scale Level Accuracy: ± 10% of full scale Slope: Positive or Negative, software selectable CompuScope 1220...
  • Page 12 • CompuScope SDK for LabVIEW For Windows 98/ME/NT/2000/XP ENVIRONMENTAL Operating Temperature: 5 degree Celsius to 40 degree Celsius Relative Humidity: Less than 80%, non-condensing Maximum Altitude: 2,000 meters WARRANTY One year parts and labor ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE CompuScope 1220...
  • Page 13: Compuscope 1220 Ordering Information

    CompuScope 1220 ordering information Hardware and upgrades Product Order No. CompuScope 1220 – 1M 122-001-002 CompuScope 1220 – 4M 122-001-003 CompuScope 1220 – 8M 122-001-004 CompuScope 1220 – 64M 122-001-005 CompuScope 1220 – 256M 122-001-006 CompuScope 1220 – 512G 122-001-007 CompuScope 1220 –...
  • Page 14: Compuscope 1220 Simplified Block Diagram

    CompuScope 1220 simplified block diagram Figure 1: CS1220 simplified block diagram CompuScope 1220...
  • Page 15: Compuscope 1220 Connectors And Headers

    The Master/Slave Timing Module is used to pass all the signals necessary to synchronize Slave CompuScope 1220 cards with the Master. NOTE FOR COMPUSCOPE 1220 DEEP MEMORY BOARD USERS: IF Y-CABLES ARE NOT CONNECTED BETWEEN THE POWER CONNECTORS OF YOUR COMPUSCOPE DEEP MEMORY CARD(S) AND THE POWER SUPPLY OF THE CHASSIS, THE DEEP MEMORY CARD(S) WILL NOT FUNCTION PROPERLY.
  • Page 16: Compuscope 1220 Throughput & Maximum Prf

    CompuScope 1220 throughput & maximum PRF A number of applications require the CompuScope 1220 to acquire data based on a rapidly occurring trigger signal. These high Pulse Repeat Frequency (PRF) applications include imaging, radar, ultrasound and lightning test. Gage has performed extensive repetitive capture benchmarks in single record mode. In this mode, the signal is captured into on-board CompuScope memory and the captured data are transferred through the PCI bus using PCI bus mastering to PC RAM.
  • Page 17 Notes CompuScope 1220...