  • Page 1 East Congo Coastal Region Kenya Nanyuki & Nothern Kenya EXTERNAL MINI-HEAT PUMP DE018CSL MANUAL Model Number : DE018CSL A Guide to the installation and operation of SMARTHEAT Heat Pumps. Please read this manual before installing and operating the Heat Pump. Keep it for future reference...
  • Page 2 Dear Customer We congratulate you on choosing a SMARTHEAT Heat Pump Water Heater. Meticulously designed, using only the highest quality materials and components, your Heat Pump Water Heater is designed to last longer. To enable your SMARTHEAT heat pump water heater to...
  • Page 3 IMPORTANT SAFETY PRECAUTIONS Important Notice: This guide provides installation and operation instructions for the Domestic Heat Pump Water Heater. Consult the dealer for any questions regarding this equipment. Attention Installer: This guide contains important information about the installation, operation and safe use of this product. This information should be given to the owner and/or operator of this equipment after installation or left on or near the heat pump.
  • Page 4 What's in the box? Name Qty. Installation &Operation Manual Remote controller Remote controller signal wire Water tank temperature sensor Drain-pipe Drain-pipe connector Rubber shock absorber Heat Pump Unit ENERGISING INGENUITY...
  • Page 5: Table Of Contents

    Please read the manual carefully before operation and keep it for future reference. Content Attention For Safety Heat Pump Unit Working Principle Installation Of The Unit Installation Of The Pipeline Installation Of Electric Devices Instruction Of Operation Initial Operation...
  • Page 6: Attention For Safety

    Attention For Safety Range of application: 1. Power supply: 230V/1N~50Hz. 2. Environment temperature: -7°C〜43°C : NOTICE This heat pump unit has anti-freezing operation. In winter when ambient is below 0℃, the unit will start automatically to keep water from freezing, so to protect the unit and water piping system.
  • Page 7 Use a dedicated socket for this unit, otherwise malfunction may occur. Keep the unit away from other home appliance or heat sources, to prevent any magnetic disturbance and ensure the unit's performance. Do not touch the power plug with wet hands. Never pull out the plug by pulling the power-cable.
  • Page 8 Do not touch the air outlet grill when fan motor is running Please select the correct fuse or breaker as per recommended. Steel wire or copper wire cannot be used as substitute for fuse or breaker else damages maybe caused.
  • Page 9: Heat Pump Unit Working Principle

    Heat Pump Unit Working Principle 1. Heat pump working process The heat pump system is mainly composed of 4 main parts, compressor, heat exchanger, evaporator and electrical control system. During the heat pump operation, compressor compresses the refrigerant gas and drives it through the whole system.
  • Page 10: Installation Of The Unit

    Installa�on Of The Unit 1. Installation check ● Make sure enough space for installation and maintenance. ● Make sure barrier-free for air inlet and outlet, also dry ventilated place. ● The power supply and its capacity, wire diameter choice should be in accordance with the electrical installation requirements.
  • Page 11: Installation Of The Pipeline

    3. Hoisting attention ● Please use four or more soft lifting belts to move the sets . ● Please use protective plate on the surface of the sets when moving, to avoid scratch and deformation. ● Recheck whether the foundation is suitable before hoisting the unit.
  • Page 12 2. Instruction (1) Pipeline installation diagram (for reference) Figure 5 Diagram ENERGISING INGENUITY...
  • Page 13: Installation Of Electric Devices

    Selection of the water pipes Model No. Inlet Outlet DE018CSL DN25 DN25 ● The bad quality water will produce more scale and sand, such water should be filtered and treated ● The water quality should be analysed before system running, measure the PH value, conductivity, Chloride ion concentration and sulphate ion concentration.
  • Page 14 4. Electric wiring diagram Figure 7 Electric Diagram ENERGISING INGENUITY...
  • Page 15 Instruc�on Of Opera�on 1. Control system specifications (1) Operating condition ● Voltage:230V〜±10%,50Hz±1Hz. ● Ambient temperature: -7〜+43℃ ● Temperature accuracy: ±1℃ (2) Main function ● Display the storage tank temperature, setting temperature and also check the coil temperature, ambient temperature and exhaust temperature etc.
  • Page 16 2. Remote controller and operation (1) Interface Display and instruction of icons 1) Controller Instruction symbol status meaning Constantly bright heat pump is on Extinguished Heat pump is off Constantly bright at cooling mode Constantly bright at heating mode...
  • Page 17 Display actual water temperature, set water temperature and display fault code Constantly bright Currently showing Celsius temperature display Show real time display Timer function is on display Currently in the on-time working hours Flashing set start time for working time...
  • Page 18 Mode 1. In the main interface, press and hold for 3 seconds to button start (and enter zero cold water time setting) / turn off the timing zero cold water function; (when parameter 64=1) 2. In the main interface, short press for more than 1 second to cancel the zero cold water function in this period;...
  • Page 19 3. Operation Instruction (1) Turn ON/OFF the Heat Pump When the controller is in the normal display state, press “ ” button for more than 1 second to switch the controller to the power ON or OFF mode. When heat pump is ON,“...
  • Page 20 “∧” or “∨” to set the minute of the real time clock; After the minute part is set, press the “ ” button again to confirm the real-time clock setting and return to the main interface; In the real-time clock setting interface, if there is no button operation for 5 seconds, the current real-time clock setting value is confirmed and return to the main interface;...
  • Page 21 (9) Forced sterilization: If the controller is in the normal display state and it is currently in the heating mode, press the “M”+“∧”+“∨” button at the same time for more than 5 seconds to activate or deactivate the “sterilization” function. The flashes at this manual “sterilization”...
  • Page 22 4. Error Code table Error Error Description Possible Causes Solution code Water flow switch Water flow switch is broken/water flow switch disconnected connection is loose /No water flow switch but set the water flow switch available Exhaust temperature too high...
  • Page 23 Ini�al Opera�on 1. Attention ● First fill up the water in the storage tank and then check the outlet till the water comes out only then switch on the Heat Pump. ● After the power is switched on, start the test running of heat pump, to see if it can function well.
  • Page 24: Operation And Maintenance

    Opera�on And Maintenance 1. To ensure the proper working of the system it should be checked and maintained regularly. Maintenance should always be done by qualified technician. During the maintenance, please pay attention to the points below: ● Control and protect the equipment, please do not change any settings by user.
  • Page 25: Technical Parameter

    Technical Parameter Model No. SHRS-018 Power Supply 380V/50Hz/3 phases Heating Capacity(kW) 18.8 Power Input(kW) 4.56 4.12 Max. Power Input (kW) 6.02 Max. Current (A) 11.0 Rated Hot Water (L/h) Expansion Valve Electronic Air Flow Direction Horizontal Working Temperature range(°C)
  • Page 26 RENEWABLE ENERGY SOLUTIONS KENYA OFFICES / BRANCHES GROUP HEAD OFFICE ADMINISTRATIVE, DISPATCHES AND BACK OFFICE Baba Dogo Road Meridian Best Western Hotel,Muranga Road, G14, Zaf Holdings Warehouses, City Centre, Nairobi, Kenya. Nairobi, Kenya. 0703 500 547 ADMIN : 0741 073 330, 0780 766 444...