Three phase Hybrid Inverter User Manual Catalog 1 Notes on this Manual ............................4 1.1 Scope of Validity ............................4 1.2 Target Group ............................. 4 1.3 Symbols Used ............................4 2 Safety ..................................4 2.1 Important Safety Instructions ........................4 2.2 Battery Safety Instructions ........................
Page 3
Three phase Hybrid Inverter User Manual 6.4 Battery Connection ..........................23 6.5 CT Connection ............................24 6.6 DRM Connection ............................ 25 6.7 Wi-Fi Connection ............................ 25 6.8 RS485 Connection ..........................25 6.9 Inverter Manipulation ..........................26 6.10 Instructions for LED Indicator ......................27 7 Fault diagnosis and solutions ..........................
Page 4
AISWEI Technology (Shanghai) Co., Ltd. Trademarks and Permissions and other AISWEI trademarks are trademarks of AISWEI Technology (Shanghai) Co., Ltd. All other trademarks and trade names mentioned in this document are the property of their respective holders. The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warranty of any kind, express or implied.
This manual is an integral part of solplanet three phase hybrid inverter, it describes the assembly, installation, commissioning, maintenance and other information of the product. Please read it carefully before operating. The descriptions in this manual are applicable to the following models of inverters: ASW08KH-T1 ASW10KH-T1 ASW12KH-T1 1.2 Target Group...
Page 6
Three phase Hybrid Inverter User Manual Grounding the PV generator. Comply with the local requirements for grounding the PV modules and the PV generator. It is recommends connecting the generator frame and other electrically conductive surfaces in a manner which ensures continuous conduction and ground these in order to have optimal protection of system and persons.
Page 7
Three phase Hybrid Inverter User Manual plug and MAINS couplers. When accessing the internal circuit of inverter, it is very important to wait 5 minutes before operating the power circuit or demounting the electrolyte capacitors inside the device. Do not open the device beforehand since the capacitors require time sufficiently discharge! Measure the voltage between terminals UDC+ and UDC- with a multi-meter (impedance at least 1M ohm) to ensure that the device is discharged before beginning work (35VDC) inside the device.
Three phase Hybrid Inverter User Manual Do not connect the ground terminals of the unit in series in case of a multiple installation. This product can cause current with a d.c component, where a residual current operated protective (RCD) or monitoring (RCM) device is used for protection in case of direct or indirect contact, only an RCD or RCM of type B is allowed on the supply side of this product.
Three phase Hybrid Inverter User Manual Danger to life due to high voltage. There is residual voltage existing in the inverter after powering off . which needs 5 min to discharge. Wait 5 min before you open the upper lid or the DC lid. 2.4 CE Directives This chapter follows the requirements of the European low voltage directives, which contains the safety instructions and conditions of acceptability for the endues system, which you must follow when installing, operating and servicing the unit.
Three phase Hybrid Inverter User Manual The wiring diagram is for reference only, and the complete electrical connection shall meet the requirements of local regulations. Please control the home loads, and make sure it’s within the “BACKUP output rating” under BACKUP mode, otherwise the inverter will shut down with an “overload fault”...
Three phase Hybrid Inverter User Manual anti-countercurrent function cannot be used. Please control the home loads, and make sure it’s within the “BACKUP output rating” under BACKUP mode, otherwise the inverter will shut down with an “overload fault” warning. Please confirm with the main grid operator whether there are any special regulations for grid connection. BACKUP1 for very important load, BACKUP2 for important or normal load.
Three phase Hybrid Inverter User Manual On charge time, solar energy will charge battery as irst priority. Then the excess solar energy will supply power to loads. If solar energy is not sufficientto charge battery and supply loads, grid will supply all the connected loads with solar energy together.
Three phase Hybrid Inverter User Manual 3.4.3.2 When Grid, Battery is available (PV is disconnected) 14) Grid will supply power to load and charge battery at the same time. If set anti-Reverse function allowable, once on the work mode of Self- use, Peak shift, battery priority, the system will not feed power to grid.
Page 14
Three phase Hybrid Inverter User Manual This plugs are reserved Description Function label PV string 1 positive input PV1+ PV string 1 Input port PV1- PV string 1 negative input PV string 2 positive input PV2+ PV string 2 Input port PV2- PV string 2 negative input COM1...
Three phase Hybrid Inverter User Manual Qualified electrician will be required for the installation. 4 Technical Data ASW08kH-T1 ASW10kH-T1 ASW12kH-T1 Model Max. PV array power 12 kWp STC 15 kWp STC 18 kWp STC Max. input voltage 1000 V MPP voltage range 180 V ~ 850 V Min.
Page 16
Three phase Hybrid Inverter User Manual ASW08kH-T1 ASW10kH-T1 ASW12kH-T1 Model Peak output apparent power 8.8kVA 11kVA 13.2kVA 17.4 A Rated Current (@400V) 11.6 A 14.5 A Max. output current 12.7A 15.9A 19.1A Max. switch time ≤20 ms Output THDi (@ Linear load) <2%...
Three phase Hybrid Inverter User Manual ASW08kH-T1 ASW10kH-T1 ASW12kH-T1 Model Inverter topology (Solar/ battery) Transformer less / Transformer less LED & App User interface Communication with BMS RS485 / CAN RS485 Features Communication with meter Communication with portal WIFI stick Integrated power control / Zero ●...
Three phase Hybrid Inverter User Manual Object Description Inverter Bracket Expansion screws and pan-head screws PV connectors (2*positive, 2*negative) WIFI stick (optional) User manual Current transformer 5.3 Mounting 5.3.1 Installation Guide ASW H-T1 Series hybrid inverter is designed for outdoor installation (IP 65). Make sure the installation site meets the following conditions: Not in direct sunlight.
Three phase Hybrid Inverter User Manual 5.3.2 Space Requirement minimum spacing Position Left 300mm Right 300mm 300mm Bottom 300mm 5.3.3 Mounting Steps 5.3.3.1 Tools required for installation. Installation tools: crimping pliers for binding post and RJ 45, screwdriver, manual wrench etc. Step 1: Screw the wall bracket on the wall Place the bracket on the wall and mark down the position of the 4 holes.
Step 4: If necessary, customer can install an anti-theft lock on the left-bottom of the inverter. 6 Electrical Connection 6.1 Grid Connection ASW H-T1 Series hybrid inverter is designed for three phase grid Voltage is 380/400V, frequency is 50/60Hz. Table 4 Cable and Micro-breaker recommended Inverter ASW08kH-T1 ASW10kH-T1 ASW12kH-T1 Cable 4~6 mm² 6~10 mm²...
Select PV modules with excellent function and reliable quality. Open-circuit voltage of module arrays connected in series should be <Max. DC input voltage; operating voltage should be conformed to MPPT voltage range. Max.DC Voltage Limitation Type ASW08KH-T1 ASW10KH-T1 ASW12KH-T1 Max. DC Voltage(V)
Three phase Hybrid Inverter User Manual Connection Steps: Step1. Checking PV module. Use multimeter to measure module array voltage. Check the PV+ and PV- from the PV string combiner box correctly. Please make sure the impedance between the positive pole and negative pole of PV to earth should be MΩ level.
Page 23
Reserve about 60mm of conductor material sectional area. Remove 10mm of insulation from the end of wire. 2 ) Step2. Connect the AC connector to the BACKUP port of the inverter with a slotted screwdriver Table 5 Cable and Micro-breaker recommended ASW08kH-T1 ASW10kH-T1 ASW12kH-T1 Inverter...
Battery breaker Before connecting to battery, please install a nonpolarized DC breaker to make sure inverter can be securely disconnected during maintenance Model ASW08KH-T1 ASW10KH-T1 ASW12KH-T1 Voltage Nominal voltage of DC breaker should be larger than maximum voltage of battery.
Three phase Hybrid Inverter User Manual Battery power cable Connection Steps: Step1. Choose the 10mm² wire and strip the cable to 15mm. Step2. Remove waterproof cover plate. 3 ) Step3. Disassemble the waterproof connector and pass the cable through the waterproof connector. 4 ) Step4.
Three phase Hybrid Inverter User Manual 6.6 DRM Connection This feature is currently reserved 6.7 Wi-Fi Connection The connection refers to “Wi-Fi stick User Manual” for detail information. WIFI Connection Steps: Step1. Plug Wi-Fi into “WIFI” port at the bottom of the inverter. Step2.
Three phase Hybrid Inverter User Manual 6.9 Inverter Manipulation Start inverter after checking all below Steps: Ensure the inverter fixed well on the wall. Make sure all the DC wirings and AC wirings are completed. Make sure the meter/CT is connected well. Make sure the battery is connected well.
Three phase Hybrid Inverter User Manual 6.10 Instructions for LED Indicator 7 Fault diagnosis and solutions The inverter is easy to maintain. When you encounter the following problems, please refer to the Solutions below, and contact the local distributor if the problem remains unsolved. The following table lists some of the basic problems that may occur during the actual operation as well as their corresponding basic solutions.
Page 29
Three phase Hybrid Inverter User Manual Content Codes Solutions DischgOverCur nothing needs to do, wait one minute for the inverter to restart. Check whether the load is in compliance with the specification. Cut off all the power and shut down all the machines; disconnect the load and plug in to restart machines, then check whether the load is short circuited if the fault has been eliminated.
Page 30
Three phase Hybrid Inverter User Manual Content Codes Solutions PV is not connected. SolarUnconect PV switch is not closed. Check PV availability. Check whether the CT is connected in the correct direction. Grid CtReverse Contact customer service if error warning continues. Check the input mode setting is correct.
Page 31
Three phase Hybrid Inverter User Manual Content Codes Solutions Restart the inverter and wait until it functions normally. bus soft fail Contact customer service if error warning continues. inv soft fail bus short inv short fan fault BusRelayFault GridRlyFault BACKUP rly fault GFCI fault Load CT fault OffgridRlyFal...
Need help?
Do you have a question about the ASW08KH-T1 and is the answer not in the manual?
Questions and answers