For The Electrician - Scotsman NME1250R Service Manual

Scotsman nme1250r ice machine: user guide
Table of Contents

Advertisement

NME1250R

FOR THE ELECTRICIAN

CONFORM TO ALL APPLICABLE CODES
The electrical power to the unit is supplied
through the junction box at the rear of the
machine.
Check the nameplate (located on the
back panel) for the voltage requirements,
REMOTE CONDENSER
and for the minimum circuit ampacity.
The machine requires a solid chassis to
WATERPROOF
earth ground wire.
(LIQUID TIGHT)
CONDUIT
The ice maker should be connected to its
own electrical circuit so it would be
individually fused. Voltage variation must
remain within design limitations, even
under starting conditions.
Electrically the remote condenser fan
motor is connected to the icemaker at the
contactor terminals for the compressor
ICEMAKER
and the fan motor operates whenever the
JUNCTION BOX
compressor operates.
Electrical connections are made at the
junction box at the back of the icemaker
and at the junction box on the remote
condenser.
The remote condenser must be wired to
the icemaker in accordance with local and
national electrical codes with a minimum
of 18 Awg. wire with an ground bonding
wire connected to the ground screws
provided in both the condenser and
machine field wiring boxes. All outdoor
wiring must be in rainproof conduit.
All external wiring must conform to
national, state, and local electrical
codes. The use of a licensed
POWER
electrician is required to perform the
SUPPLY
electrical installation.
June 1994